1 daripada 1

ABB ACS550-01-125A-4 ACS550 Variable Frequency Drive

ABB ACS550-01-125A-4 ACS550 Variable Frequency Drive

Hanya 8 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: ACS550-01-125A-4

  • Negara asal:Sweden

  • Jenis Produk: Variable Frequency Drives

  • Kod Bar: 85044095

  • Pembayaran: T/T, Western Union

  • Berat: 34000g

  • Dimensi: 265 mm (W) x 739 mm (H) x 286 mm (D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Operating within three-phase industrial power grids, the ABB ACS550-01-125A-4 variable frequency drive provides speed and torque regulation for three-phase induction motors. Engineered for normal-duty applications up to 55 kW (100 HP), this drive combines vector control, scalar control, and a built-in harmonic mitigation swing choke to optimize mechanical performance and energy efficiency. The unit is housed in a robust IP21 (UL Type 1) enclosure, making it suitable for standard side-by-side cabinet mounting or direct wall integration within clean, dry industrial environments.

Features

  • Advanced Vector Control: Supports both open-loop vector and scalar control modes to adapt to varying torque demand profiles.
  • Harmonic Reduction: Features a patented variable inductance swing choke to suppress raw harmonics at both partial and full motor loads.
  • Integrated EMC Filter: Built-in RFI/EMC filter compliant with EN 61800-3 standards for minimal electromagnetic interference.
  • Flexible Communication Protocols: Standard Modbus RTU communication integrated on-board via RS-485 interfaces.
  • Assistant Control Panel: Multilingual alphanumeric control panel featuring guided start-up assistants, real-time diagnostic readouts, and parameter backup functions.

Applications

  • Centrifugal Pumps: Variable flow control for water supply, booster stations, and waste-water processing plants.
  • Industrial Fans: Power-efficient airflow regulation in ventilation systems, cooling towers, and dust collectors.
  • Conveyor Systems: Soft-start ramp profiles and speed synchronization for production lines and bulk material handling.
  • Air Compressors: Constant pressure maintenance through continuous motor speed modulation.

Technical Specifications

Parameter Value / Specification
Manufacturer ABB
Model Number ACS550-01-125A-4
Input Voltage Range 380 - 480 V AC (3-Phase)
Input Frequency Range 48 to 63 Hz
Output Power (Normal Use) 55 kW / 100 HP
Output Current (Normal Use) 125 A
Enclosure Rating IP21 (UL Type 1)
Frame Size R4
Operating Temperature Range -15 to 40 degC (No derating) / up to 50 degC (With derating)
Shipping Weight (Calculated) 34.00 kg
Package Dimensions (Calculated) 265 mm (W) x 739 mm (H) x 286 mm (D)
Commodity Code 85044095

Connections and Interfaces

Terminal / Port Function / Signal Assignment
U1, V1, W1 Three-phase AC line input supply terminals
U2, V2, W2 Three-phase motor connection output terminals
UC+, UC- DC bus connection (for dynamic brake chopper modules)
X1: AI1 / AI2 Programmable analog inputs (Voltage 0-10V, Current 0/4-20mA)
X1: DI1 to DI6 Programmable digital inputs (PNP/NPN, 24V DC auxiliary power)
X1: RO1, RO2, RO3 Programmable form-C relay outputs (250V AC / 30V DC, max 2A)

Empirical Engineering Insights

Alternative Models & Compatibility

The ACS550-01-125A-4 is part of the mature ACS550 line. For modern migration tracks or new infrastructure planning, the ABB ACS580-01-124A-4 serves as the direct hardware replacement. Note that when migrating to the ACS580 series, control panel templates and serial parameter sets must be updated since parameter indexes and software profiles differ between the older ACS550 firmware and newer Drive-to-Drive platforms.

Application Pitfalls & Engineering Notes

To prevent thermal accumulation, ensure a minimum clearance of 200 mm above and below the R4 frame size when mounting inside electrical enclosures. Driving high-inertia loads like heavy ventilation fans or industrial centrifuges without a braking resistor can trigger overvoltage trips (Fault 2 - DC OVERVOLT) during rapid deceleration ramps. To mitigate this issue, configure the drive parameter to utilize the "deceleration-limit" function or integrate an external dynamic braking chopper unit.

Commissioning & Wiring Tips

Always configure the correct Application Macro (e.g., HVAC, 3-wire, or PID control) during initial start-up, as changing the macro later will restore default values and overwrite customized digital input routing. To suppress high-frequency electrical noise, use symmetrical shielded motor cabling and ground the shield 360 degrees at both the VFD PE terminal plate and the motor terminal box.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Prior to commencing installation or maintenance, isolate all incoming power lines. Wait at least 5 minutes after disconnecting the power supply to allow the internal DC bus capacitors to fully discharge. Always verify the absence of voltage on terminals U1/V1/W1, U2/V2/W2, and UC+/UC- with a certified multimeter before handling connection terminals.

1
Mount the R4 frame drive vertically on a flat, non-flammable wall or backplate inside an IP54 or equivalent enclosure if installed in dusty environments.
2
Connect the input line supply lines to U1, V1, and W1, and the motor power lines to U2, V2, and W2. Ensure correct terminal torque values according to Frame R4 manual requirements.
3
Route the low-voltage control signal cables (AI, DI, Relay) through separate metal conduits to prevent cross-talk and high-frequency electrical coupling with the motor cables.
4
Perform ground continuity tests on both the motor chassis and the VFD housing to ensure a low-impedance connection to the main facility earth grid.

What is the direct modern replacement for the ACS550-01-125A-4 drive?

The recommended modern migration pathway is the ABB ACS580-01-124A-4 drive. Note that while power ratings are similar, physical dimension layouts and control parameter structures vary between these series.

How do I clear a persistent 'DC OVERVOLT' fault on deceleration?

A DC overvoltage fault typically indicates regenerative energy from the motor. Extend the deceleration ramp time (Parameter 2203) or install a compatible dynamic braking chopper with braking resistors.

Can this drive be operated on single-phase supply lines?

No. The ACS550-01-125A-4 is designed exclusively for balanced three-phase 380-480 V AC inputs. Running on single-phase input will trigger phase-loss protection faults and damage internal rectifiers.

What standard enclosure class does the ACS550-01-125A-4 have?

This unit features an IP21 (UL Type 1) enclosure rating, protecting against solid objects larger than 12 mm and vertical water condensation. It is meant for indoor installations.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...