1 daripada 6

ABB CI840A S800 I/O Series PROFIBUS DP-V1 Communication Interface Module 3BSE041882R1

ABB CI840A S800 I/O Series PROFIBUS DP-V1 Communication Interface Module 3BSE041882R1

Hanya 5 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: 3BSE041882R1

  • Negara asal:Sweden

  • Jenis Produk: PROFIBUS Communication Modules

  • Kod Bar: 85389091

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 150 mm x 100 mm x 130 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Managing cyclic and acyclic fieldbus communications within distributed automation topologies, the ABB CI840A 3BSE041882R1 serves as a high-speed PROFIBUS DP-V1 master/slave link module for the S800 I/O system. This module facilitates continuous data exchange between the host controller and remote I/O devices, translating protocols with deterministic accuracy. When paired with a compatible Module Termination Unit (MTU), it supports full 1+1 media and hardware redundancy, making it highly suitable for mission-critical industrial processes. The compact design mounts directly onto standard DIN rails via the termination unit, allowing easy integration into existing System 800xA and Compact Product Suite infrastructures.

Features

  • PROFIBUS DP-V1 Connectivity: Handles cyclic process data alongside acyclic parameter, diagnostic, and alarm information.
  • Hardware Redundancy Support: Enables dual-line, hot-standby redundancy setups when combined with TU846 or TU847 terminal blocks.
  • Hot-Swappable Operation: Modules can be replaced under power without interrupting active communication bus traffic (when in redundant configuration).
  • No Internal Batteries Required: Minimizes routine maintenance tasks and environmental footprint.
  • RoHS & Environmental Compliance: Meets strict European standards for hazardous materials reduction.

Applications

  • S800 distributed I/O systems in process control architectures.
  • System 800xA and Compact Product Suite control networks.
  • High-availability systems such as petrochemical plants, power generation facilities, and water treatment operations.

Technical Specifications

Parameter Value
Manufacturer ABB
Model / Part Number CI840A / 3BSE041882R1
Protocol Type PROFIBUS DP-V1 (Master/Slave)
Redundancy Options 1+1 Line & Module Redundancy (requires TU846/TU847 MTU)
Module Dimensions (W x H x D) 54 mm x 119 mm x 96 mm
Net Weight 0.2 kg
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 150 mm x 100 mm x 130 mm
WEEE Category 5 (Small Equipment under 50 cm)
HS Code / Customs Tariff Number 85176200

Empirical Engineering Insights

Alternative Models & Compatibility

The CI840A (3BSE041882R1) acts as a direct form-factor replacement for the legacy CI840 module. However, when configured in redundant pairs on a TU847 Module Termination Unit, both modules must run identical firmware and hardware revisions. Mixing a legacy CI840 and a newer CI840A in the same redundant base will cause failover configuration mismatch errors, preventing the secondary unit from taking control during a primary unit fault.

Application Pitfalls & Engineering Notes

Ensure that the PROFIBUS networks are terminated correctly at the extreme ends of the physical trunks. In redundant setups, activating internal active termination on intermediate nodes or on a non-terminal TU847 block will severely degrade signal integrity, causing intermittent communication dropouts and CRC errors. Additionally, check the module power distribution; sudden voltage dips on the auxiliary 24V DC feed below 19.2V DC will trigger an automatic module reset.

Commissioning & Wiring Tips

The station address for the PROFIBUS interface must be selected using the hardware rotary switches located on the front of the module housing. This address is only read during the initial power-on boot sequence. If you adjust the rotary switches while the module is powered, the change will not take effect until the module is fully power-cycled or soft-rebooted via the controller software.

Installation Guidelines

CRITICAL WARNING: De-energize all primary 24V DC power feeds before inserting or removing the module from its termination unit. Although hot-swapping is physically possible during dual-module redundant operation, conducting hot-swapping on a single-channel configuration will instantly drop all connected S800 I/O modules, resulting in immediate loss of field signal feedback and process shutdown.
1
Set the correct PROFIBUS address using the hardware rotary switches located on the front face of the CI840A module.
2
Align the module guides with the matching slot on the TU846 or TU847 Module Termination Unit.
3
Firmly slide the module into the terminal base until the locking tabs snap into place. Secure the locking mechanism to prevent vibration displacement.
4
Connect the DB9 PROFIBUS network cable to the termination unit and apply 24V DC power. Verify that the 'PWR' and 'RUN' LED status lights show green.
Loading product navigation…

Can the CI840A module be hot-swapped during active process control?

Yes, if configured in a redundant pair on a TU846 or TU847 Module Termination Unit, a faulty unit can be hot-swapped under power without interrupting communication.

What is the function of the rotary switches on the front panel?

The rotary switches are used to configure the unique PROFIBUS station address (01 to 125) for the module before booting.

Can a CI840 and a CI840A be mixed in a redundant configuration?

No. Both modules in a redundant pair must have identical model numbers and firmware versions to ensure proper redundant failover synchronization.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Sweden

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...