1 daripada 3

ABB HIEE205010R0003 UNS3020A-Z V1 Ground Fault Relay

ABB HIEE205010R0003 UNS3020A-Z V1 Ground Fault Relay

Hanya 4 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: HIEE205010R0001

  • Negara asal:Switzerland

  • Jenis Produk: Ground Fault Relay

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 5200g

  • Dimensi: 44 cm x 17 cm x 10 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The ABB HIEE205010R0003 (also designated as the UNS3020A-Z V1 Ground Fault Relay) is a specialized protection and insulation monitoring device engineered for industrial power distribution and excitation networks. This hardware unit incorporates an adjustable trip mechanism configurable via front-mounted dip switches to manage specific electrical protection parameters. It features comprehensive diagnostic signaling through up to four integrated LEDs that provide real-time indicators for active protection timing, trip logs, sensor connection faults, and circuit breaker status. Designed for continuous monitoring, the status memory circuit retains trip information for up to 48 hours of inactivity without requiring external auxiliary power, providing critical diagnostic availability during circuit breaker isolation sequences.

Features

  • Front-accessible dip switches for direct configuration and adjustment of the trip unit parameters.
  • Up to four diagnostic status LEDs providing dedicated signaling for individual protection functions.
  • Multi-state LED signaling indicating protection timing, pre-alarm status for protection L, and tripped states.
  • Automated fault detection for connected current sensors and opening solenoid continuity failures.
  • Non-volatile trip indication memory retaining fault status for 48 hours of inactivity without auxiliary power.
  • Auxiliary testing compatibility via connection ports for PR030/B battery units, PR010/T test sets, or BT030 wireless units.

Applications

  • Ground fault protection and isolation tracking in industrial circuit breaker networks.
  • Status monitoring and pre-alarm management in automated power distribution systems.
  • Excitation system isolation control and protection logging in generation plants.

Technical Specifications

Property Characteristics
Manufacturer ABB
Model HIEE205010R0003 / HIEE205010R0001
Series Designation UNS3020A-Z V1
Device Type Ground Fault Relay
User Interface Front Dip Switches / Diagnostic LEDs
Protection Memory Retention 48 hours (without auxiliary supply)
Diagnostic Status Indicators Timing, Tripped, Pre-alarm (L), Connection Failure

Installation Guidelines

  • Ensure all main circuit breaker contacts are open and primary power distribution lines are fully isolated before installing the unit.
  • Mount the relay securely within the designated panel space, ensuring clear visibility and access to the front dip switches.
  • Connect all current sensors and opening solenoid lines according to the certified terminal schematic to prevent connection failure alarms.
  • For diagnostic interrogation after a 48-hour period of inactivity, connect an approved PR030/B battery module or a BT030 wireless communication interface to the specified testing port.
Loading product navigation…

How can the trip parameters be configured on this relay?

The trip settings on the device can be fully adjusted and configured using the dedicated dip switches located on the front panel.

How long does the trip indication remain available without auxiliary power?

The protection tripped indication remains stored and active for up to 48 hours of inactivity after a trip event, even when the circuit breaker is open.

What happens if a trip query needs to be made more than 48 hours after an event?

If the period exceeds 48 hours, the fault data can be retrieved by connecting a PR030/B battery unit, a PR010/T test unit, or a BT030 wireless communication module.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Switzerland

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...