1 daripada 3

ABB REF615 Standard Configuration C Feeder Protection and Control

ABB REF615 Standard Configuration C Feeder Protection and Control

Hanya 4 item tinggal dalam stok
  • Pengilang: ABB

  • No. Produk: REF615-C

  • Negara asal:Sweden

  • Jenis Produk: Feeder Protection and Control

  • Kod Bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 3500g

  • Dimensi: 177 mm x 177 mm x 201 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The REF615 is a dedicated feeder protection and control relay designed for the protection, control, measurement and supervision of utility substations and industrial power systems. As part of the ABB Relion 615 series, this device provides standard configuration C, which is specifically tailored for applications requiring comprehensive overcurrent and earth-fault protection with additional voltage and frequency measurement capabilities. The REF615 integrates numerical protection functions, local human-machine interface (LHMI) displays, programmable light-emitting diodes (LEDs), and extensive communication capabilities into a single compact unit. It supports native implement of the IEC 61850 standard for communication in substations, as well as Modbus TCP/IP, Modbus RTU, DNP3, and Profibus using optional communication modules. The relay handles current and voltage inputs via instrument transformers, executing real-time monitoring and trip logic to ensure the stability and safety of distribution networks.

Features

  • Complete overcurrent and directional/non-directional earth-fault protection for distribution feeders.
  • Integrated voltage and frequency protection functions for grid stability and load shedding.
  • Support for parallel redundancy protocol (PRP) and high-availability seamless redundancy (HSR).
  • Native IEC 61850 implementation including horizontal GOOSE messaging for fast inter-relay interlocking.
  • Web human-machine interface (WHMI) enabling secure remote access via a standard web browser.
  • Built-in trip-circuit supervision (TCS) and continuous self-supervision of hardware and software.
  • Flexible graphical configuration using the Protection and Control IED Manager PCM600 tool.

Applications

  • Utility distribution substations.
  • Industrial power distribution systems.
  • Main and feeder protection for medium-voltage networks.
  • Backup protection for power transformers and high-voltage transmission lines.
  • Load shedding and grid integration of distributed generation.

Technical Specifications

Parameter Specification
Manufacturer ABB
Product Series Relion 615 series
Model REF615 Standard Configuration C (REF615-C)
Rated Frequency 50 / 60 Hz
Current Inputs 4 (3 phase + residual)
Voltage Inputs 3 or 5 (depending on explicit variant configuration)
Communication Protocols IEC 61850, Modbus TCP/IP, Modbus RTU, DNP3, Profibus
Local Interface LCD, 3 LEDs (Protection indicators), 11 Programmable LEDs
Configuration Software PCM600 Protection and Control IED Manager
Approximate Weight 3.5 kg
Dimensions (W x H x D) 177 mm x 177 mm x 201 mm

Installation Guidelines

Panel Mounting

The relay must be mounted securely into a cutout panel using the provided mounting brackets and screws. Ensure proper clearance is maintained around the rear enclosure to facilitate adequate natural cooling and air ventilation.

Grounding and Shielding

Connect the dedicated grounding terminal on the rear of the device chassis directly to the substation earth bar using a heavy-gauge copper wire. All communication cables, especially serial links like RS-485 and Ethernet copper lines, must use high-quality shielded twisted-pair (STP) cables with the shields grounded properly to minimize electromagnetic interference (EMI).

Cable Routing and Termination

Separate low-voltage signal wires and communication cables from high-voltage primary current transformer (CT) and voltage transformer (VT) secondary wiring. Ensure all binary inputs and signal outputs are terminated correctly according to the connection diagram provided with standard configuration C, verifying correct polarity for all DC auxiliary supply lines.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB REF615 Standard Configuration C Feeder Protection and Control

Loading PDF, please wait…

How can the configuration of the REF615 relay be modified?

The engineering, parameterization, and graphical configuration of the relay are performed using the PCM600 Protection and Control IED Manager software.

What communication interfaces are supported on the rear panel?

Depending on the specific hardware options selected, the rear panel supports RJ-45 galvanic Ethernet, LC fiber optic Ethernet, RS-485 serial, and glass fiber serial interfaces.

What function does the integrated Web HMI provide?

The WHMI allows authorized personnel to securely view measurements, event lists, disturbance records, and status information using a standard web browser.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Sweden

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...