Product Overview

The 8B0P0440HW00.000-1 (8B0P0440HW000001) is a high-capacity passive power supply module engineered for the B&R ACOPOSmulti drive system. This unit acts as the central energy entry point for the DC bus, converting a three-phase AC mains input into a stabilized DC voltage for multiple inverter modules. Designed for high-voltage (HV) applications and rated at 44 A, the 8B0P0440HW00.000-1 is optimized for wall-mounting within control cabinets, providing a robust power foundation for large-scale automation lines, CNC machining centers, and heavy-duty material handling systems. Its passive design offers a cost-effective and reliable solution for systems that do not require regenerative energy recovery to the mains.

Technical Configuration

This power supply is characterized by its high power density and specific integration requirements for the ACOPOSmulti backplane.

  • High Power Capacity: Supports an installed load of up to 30.4 kVA, capable of powering several high-torque axes simultaneously across the shared DC bus.

  • Passive Rectification: Utilizes a ruggedized bridge rectifier circuit to provide a stable DC link from a 380-500 VAC input, characterized by a low inrush current of 10 A.

  • Thermal Management: Despite its high output, it maintains a low power dissipation of approximately 300 W at continuous power, supported by the efficient wall-mounting heat sink design.

  • Safety Discharge: Features an integrated discharge capacitance of 0.9 uF, essential for managing the energy levels of the DC bus during power-down sequences.

Technical Specifications

Feature Details
Model 8B0P0440HW00.000-1
Brand B&R Industrial Automation
Nominal Current 44 A
Mains Input Voltage 3x 380 to 3x 500 VAC (plus or minus 10 percent)
Mains Frequency 50 / 60 Hz (plus or minus 4 percent)
Installed Load Max. 30.4 kVA
Power Dissipation Approx. 300 W (Continuous)
Inrush Current 10 A (at 400 VAC)
Discharge Capacitance 0.9 uF
Mounting Width 263 mm (Wall Mounting)
Weight Approx. 6.1 kg
Shipping Weight 7.0 kg

FAQs

What is the minimum time required between power cycles?

The 8B0P0440HW00.000-1 requires a switch-on interval of greater than 120 seconds. This delay is critical to allow the internal inrush current limiting components to cool down and reset before the next power-up.

Does this passive module support energy regeneration?

No, this is a passive power supply module. Any regenerative energy produced by the motors during deceleration must be dissipated via an external braking resistor or stored in a capacitor module; it cannot be fed back into the mains.

What size cabinet is required for the 263 mm mounting?

The 263 mm refers to the specialized wall-mounting width for the ACOPOSmulti rack. Ensure the cabinet depth and height can accommodate the 6.1 kg unit while allowing for the necessary vertical clearance for cooling.


Engineering Installation and Power Safety Guidelines

  • DC Bus Voltage Warning: WARNING: The DC bus carries lethal voltages (up to 800 VDC depending on mains input). After disconnecting the power, wait at least 5 minutes for the discharge capacitance to bring the bus voltage to a safe level before performing any service.

  • Inrush Management: Ensure the upstream circuit breakers are sized to handle the 10 A inrush current. Rapidly cycling the power (faster than the 120 s interval) will bypass the soft-start protection and may cause the primary fuse to blow or damage the rectifier.

  • Mechanical Integrity: The module weighs approximately 6.1 kg. Use the designated wall-mounting brackets and ensure the mounting surface is vibration-free. High-frequency vibration can lead to terminal fatigue on the high-current AC input connections.

  • Wiring and Grounding: Use three-phase industrial cabling rated for at least 600 V and 50 A. The module must be grounded via the central grounding stud on the ACOPOSmulti rack to prevent common-mode noise from affecting the drive communication.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Amerika Syarikat
Power source
Dikuasakan oleh AC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...