1 of 1

B&R X20BC0063 X20 PROFIBUS DP Bus Controller

B&R X20BC0063 X20 PROFIBUS DP Bus Controller

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20BC0063

  • Country of origin:Amerika Syarikat

  • Product Type: Bus Controllers

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The X20BC0063 (X20BC0063) is a high-performance bus controller designed to integrate the modular B&R X20 System into existing PROFIBUS DP fieldbus networks. Serving as the gateway between the X20 I/O backplane and the master control network, this controller enables seamless communication in complex automation environments—such as automotive production lines, heavy material handling systems, and large-scale process machinery. By providing a standardized 9-pin DSUB interface, the X20BC0063 ensures reliable, deterministic data exchange, allowing engineers to maintain interoperability between B&R hardware and heterogeneous industrial control architectures.

Technical Configuration

This module acts as the communication head for an X20 I/O station, managing the cyclic data transfer between the PROFIBUS master and the distributed I/O slices.

  • PROFIBUS Connectivity: Features a standard 9-pin DSUB connector for easy integration into existing PROFIBUS DP architectures, supporting high-speed fieldbus communication.

  • System Integration: As part of the X20 ecosystem, it provides a compact, scalable interface. Note that the system requires an independent bus base, a dedicated power supply module, and a compatible terminal block to complete the I/O node assembly.

  • Diagnostic Visibility: Equipped with an integrated LED array to provide real-time status for overall module health, current bus function, and active data transfer cycles, enabling rapid field diagnostics and reduced downtime.

  • Power Efficiency: Optimized for low-energy operation with a maximum power consumption of only 2.3 W, minimizing the thermal load on the control cabinet and allowing for high-density I/O configurations.

Technical Specifications

Attribute Specifications
Model X20BC0063
Brand B&R (Bernecker + Rainer)
Module Type Bus Controller (PROFIBUS DP)
Interface 1x PROFIBUS DP (9-pin DSUB)
Power Consumption 2.3 W
Status Indicators Module status, bus function, data transfer LEDs
System Compatibility B&R X20 System
Shipping Weight 2 kg

Industrial Hardware FAQs

Does the X20BC0063 include the required terminal block for I/O assembly?

No. This unit is the controller head only. For a complete installation, you must order the compatible X20 bus base, the appropriate X20 power supply module, and the necessary terminal blocks separately based on your specific I/O density requirements.

How does the module signal a communication loss on the PROFIBUS network?

The "bus function" LED provides immediate visual status. If the PROFIBUS link is interrupted or if the controller loses communication with the PROFIBUS master, this indicator will change state. Detailed error codes and diagnostic registers can be accessed via the master controller software to identify the specific bus fault.

What is the maximum number of I/O modules this controller can manage?

The X20BC0063 manages the total number of I/O slices allowed within the specific X20 bus base limitations. Ensure that the total power consumption of the connected I/O modules does not exceed the capacity of your chosen power supply module.

Field Commissioning and Safety Guidelines

PROFIBUS Termination Protocols

When connecting the PROFIBUS DP cable to the 9-pin DSUB connector, ensure that the network is properly terminated at both physical ends of the bus segment. Improper termination will cause signal reflections, leading to cyclic communication errors and increased "collision" or "data transfer" fault rates within the diagnostic logs.

Shielding and Grounding

The PROFIBUS cable shield must be correctly bonded to the metallic housing of the DSUB connector. Ensure that the cabinet DIN rail is clean and firmly bonded to the primary earth ground to provide a low-impedance path for EMI protection, which is vital when operating in environments with significant electrical noise.

Bus Base and Power Assembly

When assembling the station, ensure all X20 modules are snapped firmly onto the bus base to ensure backplane communication. Verify that the power supply module is positioned correctly relative to the controller to prevent power delivery bottlenecks. Once assembled, perform a visual check of the terminal block seating to ensure no pins are bent during the installation process.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...