1 daripada 1

Beckhoff BK7350 Modbus Bus Coupler

Beckhoff BK7350 Modbus Bus Coupler

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: BK7350

  • Negara asal:Jerman

  • Jenis Produk: Modbus Bus Couplers

  • Pembayaran: T/T, Western Union

  • Berat: 100g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Beckhoff BK7350 Modbus Bus Coupler

Description

Integrating Modbus RTU/ASCII networks with modular I/O systems, the Beckhoff BK7350 bus coupler serves as a reliable interface between the Modbus fieldbus and Beckhoff Bus Terminals. This compact module manages communication for up to 64 Bus Terminals, with expansion capabilities reaching up to 255 terminals using a K-bus extension. The BK7350 automatically configures and maps the connected digital and analog peripheral signals to the Modbus process image, ensuring seamless data exchange in decentralized automation architectures.

The unit features a standard RS485 physical interface via a 9-pin D-sub connector, supporting data transfer rates from 150 baud up to 38,400 baud. Configuration can be executed directly using the integrated rotary address switches or via the KS2000 software tool. Designed for harsh industrial environments, the module features robust electrical isolation between the power contacts, supply voltage, and the fieldbus network.

Features

  • Supports Modbus RTU and Modbus ASCII protocols with RTU as the default configuration.
  • Connects up to 64 Bus Terminals directly, expandable to 255 terminals via K-bus extension.
  • Provides up to 512 bytes of input data and 512 bytes of output data capacity.
  • Configurable addressing and parameters via physical rotary switches or KS2000 software.
  • Integrated RS485 interface utilizing a standard 9-pin D-sub connection.
  • Electrical isolation of 500 V between power contacts, supply voltage, and fieldbus.

Applications

  • Industrial manufacturing and assembly line automation.
  • Process control systems in water and wastewater treatment facilities.
  • Building automation and HVAC control networks.
  • Remote telemetry and distributed I/O data acquisition.

Technical Specifications

Manufacturer Beckhoff
Part Number/Model BK7350
Product Type Modbus Bus Coupler
Number of Bus Terminals 64 (up to 255 with K-bus extension)
Max. Number of Bytes Fieldbus 512 byte input and 512 byte output
Digital Peripheral Signals 1,020 inputs/outputs
Analog Peripheral Signals 256 inputs/outputs
Protocol Modbus RTU, Modbus ASCII (default: RTU)
Data Transfer Rates 150 baud to 38,400 baud
Bus Interface D-sub 9-pin, RS485
Data Transfer Medium Screened, twisted copper cable 2 x 0.25 mm² (RS485)
Power Supply 24 V DC (-15% / +20%)
Input Current 320 mA maximum
Starting Current 2.5 x continuous current
Recommended Fuse <= 10 A
Current Supply K-bus 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Electrical Isolation 500 V (power contact / supply voltage / fieldbus)
I/O Communication Types Read/write access, optionally bit-oriented or word-oriented
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Installation Position Variable
Weight Approx. 100 g

Connections and Interfaces

Interface Type Connection Specification Function
Bus Connection 9-pin D-sub (female) RS485 Modbus communication interface
Power Supply Connection Spring-force terminals 24 V DC system and power contact supply
Internal Bus K-bus contact strip Data and power connection to Bus Terminals

Installation Guidelines

  • Mounting: Mount the module on a standard 35 mm DIN rail (EN 60715) in a clean, dry control cabinet.
  • Wiring: Use screened, twisted-pair copper cabling (2 x 0.25 mm²) for the RS485 fieldbus line to prevent electromagnetic interference.
  • Grounding: Ensure the DIN rail is properly grounded to the functional earth (FE) of the control cabinet.
  • Ventilation: Maintain adequate clearance above and below the module to allow natural convection cooling. Do not block the ventilation slots.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex ec IIC T4 Gc
  • IECEx: Ex ec IIC T4 Gc
Loading product navigation…

What is the maximum number of Bus Terminals that can be connected to the BK7350?

The BK7350 supports up to 64 Bus Terminals directly. With a K-bus extension, this capacity can be expanded to support up to 255 Bus Terminals.

Which Modbus protocols are supported by the Beckhoff BK7350?

The BK7350 supports both Modbus RTU and Modbus ASCII protocols, with Modbus RTU configured as the default setting.

How is the station address configured on the BK7350?

The station address can be configured manually using the integrated rotary address switches on the module, or via the KS2000 software tool.

What are the power requirements for the BK7350 Modbus Bus Coupler?

The module requires a 24 V DC (-15% / +20%) power supply with a maximum input current of 320 mA.

Does the BK7350 have hazardous area certifications?

Yes, the BK7350 is certified for hazardous areas with ATEX (II 3 G Ex ec IIC T4 Gc) and IECEx (Ex ec IIC T4 Gc) markings.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...