1 daripada 1

Beckhoff EK1501-0100 EtherCAT Coupler with ID Switch

Beckhoff EK1501-0100 EtherCAT Coupler with ID Switch

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: EK1501-0100

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Couplers

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 51 mm x 100 mm x 69 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

To enable reliable communication across long-distance industrial networks, the Beckhoff EK1501-0100 integrates multi-mode fiber optic media conversion directly with EtherCAT Terminal systems. This device bridges the gap between 100BASE-FX optical networks and standard RJ45 copper connections, serving as a highly secure communication node. By utilizing multi-mode glass fiber, this coupler allows connection distances of up to 2000 meters between individual stations, bypassing the electromagnetic interference vulnerabilities of traditional copper cabling.

The module features an integrated three-digit decimal ID switch, which allows the configuration of up to 4096 unique station IDs. This hardware-defined addressing is critical for Hot Connect topologies, enabling system modules to be connected or disconnected during live operation. The coupler generates an internal E-bus current of up to 2000 mA, powering the connected ELxxxx terminal series directly from the incoming 24 V DC system supply.

Key Technical Features

  • High-Distance Fiber Connection: Supports 100BASE-FX multi-mode fiber (50/125 um glass fiber) using a robust SC Duplex connection.
  • Hardware Address ID Switch: Configures station IDs up to 4096 via physical rotary switches, facilitating complex Hot Connect applications.
  • Robust Power Supply: Accepts 24 V DC system power and supplies up to 2000 mA current to the internal E-bus.
  • Electrical Isolation: Complete 500 V galvanic isolation between the power contacts, internal supply voltage, and Ethernet ports.
  • Ex Certification: Standardized with ATEX Zone 2 rating (II 3 G Ex nA IIC T4 Gc) for hazardous explosive atmospheres.

Industrial Applications

  • Wind Power & Renewable Energy: Optical media conversion prevents lightning damage and noise propagation between tower base and nacelle.
  • Water/Wastewater Treatment: Bridges expansive process areas spanning up to 2000 meters without active repeaters.
  • Automotive Assembly Lines: Leverages Hot Connect IDs for tool changers, allowing quick physical re-tooling without software reconfiguration.
  • Hazardous Zones: Safely deploys I/O nodes in explosive-prone environments requiring ATEX Zone 2 ratings.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number EK1501-0100
Protocol EtherCAT
Data Transfer Medium Multi-mode glass fiber 50/125 um
Max. Distance Between Stations 2000 m (100BASE-FX)
Bus Interface 1 x SC Duplex
Power Supply 24 V DC (-15% / +20%)
E-bus Current Supply 2000 mA
Configurable IDs 4096 (via 3-digit decimal ID switch)
Electrical Isolation 500 V (power contact / supply voltage / Ethernet)
Connection Cross-Section (Solid/Stranded) 0.08 to 2.5 mm2 (AWG 28-14)
Stripping Length 8 to 9 mm
Protection Rating IP20
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Dimensions (W x H x D) 51 mm x 100 mm x 69 mm
Product Weight 190 g
Shipping Weight 2 kg (including diagnostic protective packaging)
Country of Origin Germany

Empirical Engineering Insights

Alternative Models & Compatibility

The EK1501-0100 serves as a direct upgrade to copper-based couplers (such as the EK1100) when running control signals over long distances or through electrically noisy environments. It is functionally identical to the standard EK1501 multi-mode coupler but includes the three-decade rotary ID switch necessary for dynamic Hot Connect topologies. When swapping or designing network nodes, ensure your TwinCAT system configuration aligns with the physical position of the rotary switches on the unit.

Application Pitfalls & Engineering Notes

One of the most common configuration errors involves exceeding the 2000 mA E-bus current limit. Calculating the sum current consumption of all connected ELxxxx terminals is critical. If your terminal configuration exceeds 2 A, you must inject fresh current using an EL9410 or EL9400 power supply terminal to prevent communication instability or dropouts.

Commissioning & Wiring Tips

The physical ID switches must be configured before applying power to the coupler. The Beckhoff ASIC reads these hardware settings only during the boot cycle. If you change the ID switches while the unit is powered, the new ID will not register until a complete power cycle has occurred. Ensure the SC Duplex optical connectors are cleaned with appropriate optical tools prior to insertion to prevent high signal attenuation.

Installation Guidelines

CRITICAL WARNING

Always completely isolate and de-energize the entire control cabinet before inserting or removing the EtherCAT Coupler or any associated I/O modules. Failure to de-energize can lead to destructive electrical arcs, permanent damage to the E-bus contacts, or CPU bus faults.

1
Snap the EK1501-0100 directly onto a standard 35 mm DIN rail (conforming to EN 60715) until the lock clicks securely into place.
2
Set the physical station ID via the three rotary decimal switches on the front face prior to powering up the system.
3
Securely plug the clean multi-mode fiber optic cable into the SC Duplex port and verify that the physical latch is locked.
4
Apply 24 V DC power supply to the US and UP terminal contacts and monitor LED diagnostics to confirm successful initialization.
Loading product navigation…

What is the primary function of the ID switch on the EK1501-0100?

The ID switches allow physical setting of a unique decimal identifier (up to 4096) directly on the device. This is crucial for Hot Connect configurations, letting TwinCAT recognize changing I/O topologies dynamically.

How do I expand the E-bus current capability if I exceed 2000 mA?

If the sum current consumption of your connected ELxxxx terminals exceeds 2000 mA, you must integrate an additional power feed terminal, such as the EL9410 or EL9400, to supplement current on the internal E-bus.

Does the EK1501-0100 support single-mode fiber optic cables?

No, the EK1501-0100 is specifically designed for multi-mode glass fiber (50/125 um) connections up to 2000 meters. For single-mode optical fiber installations, alternative models must be selected.

What happens if I change the decimal ID switch while the coupler is powered?

The coupler only reads the hardware ID switch setting during its startup phase. If you change the switches mid-operation, you must perform a power cycle for the new ID to take effect.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...