1 of 1

BECKHOFF EL2828 8-Channel Digital Output EtherCAT Terminal 24 V DC

BECKHOFF EL2828 8-Channel Digital Output EtherCAT Terminal 24 V DC

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EL2828

  • Country of origin:Jerman

  • Product Type: EtherCAT Terminal

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The EL2828 (EL2828) EtherCAT Terminal provides eight electronically protected digital outputs operating at a 24 V DC nominal voltage. Utilizing advanced 2-wire connection technology, this High Density (HD) module is engineered to drive diverse loads, including ohmic, inductive, and capacitive field actuators.

Deployable across heavy industrial environments—such as automotive stamping, automated sorting lines, and food packaging facilities—the module delivers exceptional power routing capability. By supporting up to 2 A per individual channel within a compact 12 mm wide form factor, the terminal eliminates the need for external interposing relays on high-current loads, optimizing control cabinet space and dropping operational failure points to prevent system downtime.

Electronic Protection and Switching Characteristics

The EL2828 features robust internal driver circuitry equipped with short-circuit current limitation (typically restricting faults under 40 A) and native reverse voltage protection. It is uniquely specified to handle inductive breaking energy up to 1.2 J per channel, allowing safe de-energization of solenoids and small DC valves without external flyback diodes.

The physical structure maps an 8-bit output profile directly into the cyclic EtherCAT E-bus process image, completely eliminating manual hardware addressing or software configuration parameters. Its high-efficiency switching speed showcases a typical turn-on time ($T_{ON}$) of 60 µs and a turn-off time ($T_{OFF}$) of 250 µs, facilitating precise timing control for rapid automation sequences.

Technical Specifications

Parameter Specifications
Model EL2828
Brand BECKHOFF
Origin Germany
I/O Technology EtherCAT Terminal (E-bus communication)
Output Count 8 outputs
Cabling Method 2-wire connection
Nominal Operating Voltage 24 V DC (-15 % / +20 %)
Maximum Output Current 2 A per channel (Maximum total sum 10 A)
Short-Circuit Current Typ. less than 40 A
Breaking Energy Max Less than 1.2 J per channel
Switching Performance Typ. TON: 60 µs / Typ. TOFF: 250 µs
Reverse Voltage Protection Yes
E-bus Current Draw Typ. 110 mA
Power Contact Current Draw Typ. 15 mA + load current
Galvanic Isolation 500 V (E-bus to field potential)
Process Image Bit Width Outputs: 8 bits
Housing Design HD (High Density) housing with status LEDs
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 70 g
Operating Temperature -25 to +60 deg C (Vertical installation required)
Storage Temperature -40 to +85 deg C
Protection Rating IP20
Compliance Markings CE, UL

Product FAQs

What are the specific advantages of the 2-wire connection technology over standard 1-wire layouts?

The 2-wire architecture provides both the 24 V DC output signal and a dedicated 0 V DC ground return point for each of the eight channels directly on the terminal block face. This design streamlines cabling by allowing field actuators to wire back to the module sequentially, eliminating external ground termination blocks inside the panel.

How does the 10 A sum current limit restrict operation if all channels can pull 2 A?

While any individual channel can source up to 2 A continuously, the internal power contact bus bars have a maximum physical limit of 10 A. This means that if five channels are loaded to their full 2 A capacity ($5 \times 2\text{ A} = 10\text{ A}$), the remaining three channels must remain idle to avoid exceeding the safety threshold.

Does this terminal module utilize Distributed Clocks (DC) for synchronized switching?

No, the EL2828 operates without Distributed Clocks. Output switching commands are updated and executed at the module level on the next immediate frame cycle received from the master EtherCAT controller.


Field Termination Guidelines and Safety Standards

  • HD Spring-Cage Cabling Protocols: Open the high-density terminal points using a standard flat-blade technical screwdriver. Strip field wires to a length of 8 to 9 mm. The connection points accommodate solid wire (s) from AWG 28 to 16, stranded wire (st) from AWG 22 to 16, or ferrule-insulated lines (f) from AWG 26 to 19. Ensure ferrules are squarely crimped to secure long-term mechanical grip.

  • Mechanical Interlocking and Heat Dissipation: Mount the module vertically on a standard 35 mm DIN rail conforming to EN 60715. Ensure the interlocking double slot and key connection points clip together firmly with adjacent units to establish continuous backplane contact. Vertical orientation is mandatory; running the module under full 10 A load at high ambient temperatures requires active panel airflow to stay within the -25 to +60 deg C operating window.

  • Inductive Transient Management: Although the EL2828 features integrated suppression circuitry rated for less than 1.2 J, regularly driving large inductive loads or high-duty-cycle solenoids can cause thermal accumulation. For large field coils, it is highly recommended to mount an external freewheeling diode across the actuator terminals to suppress reverse voltage spikes right at the source.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih
Country of origin
Jerman
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...