1 daripada 1

Beckhoff ELM3502-0000 ELM Series 2-Channel Analog Input EtherCAT Terminal

Beckhoff ELM3502-0000 ELM Series 2-Channel Analog Input EtherCAT Terminal

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: ELM3502-0000

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Measurement Terminals

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 100 mm x 95 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to meet the stringent demands of high-speed industrial metrology, the Beckhoff ELM3502-0000 measurement terminal captures precise differential signals from strain gauges and resistor bridges. Supporting full, half, and quarter-bridge topologies, this high-end module features 24-bit resolution and simultaneous sampling speeds up to 20 ksps per channel. Enclosed in a robust zinc die-cast housing for optimal thermal and electrical shielding, it integrates seamlessly into Beckhoff EtherCAT control architectures, utilizing Distributed Clocks for synchronized, sub-microsecond multi-channel alignment.

Features

  • Dual-channel high-speed differential measurement interface.
  • Full, half, and quarter-bridge resistor strain gauge input compatibility.
  • Selectable oversampling factor from 1 to 100 (up to 20 ksamples/s).
  • Integrated diagnostic features, including broken wire and short-circuit monitoring.
  • Advanced DSP features: TrueRMS, non-linear scaling, PeakHold, integrator, and differentiator filters.
  • Robust zinc die-cast enclosure with integrated status LEDs.

Applications

  • Industrial test benches and dynamic dynamometer load monitoring.
  • Real-time structural health monitoring and strain analysis.
  • High-speed weighing systems and inline material tensioning control.
  • Geotechnical and civil engineering monitoring systems.

Technical Specifications

Manufacturer Beckhoff
Article Number / SKU ELM3502-0000
Number of Channels 2 differential inputs
Supported Sensors Resistor bridge, strain gauges (full, half, quarter bridge)
Connection Technology 2-, 3-, 4-, 5-, or 6-wire configuration
Connection Type Push-in, 6-pin service plug
Resolution 24-bit (including sign)
Max. Sampling Rate 20 ksps (50 us) per channel, simultaneous
Oversampling Factor n = 1 to 100 (selectable)
Internal Input Resistance > 4 MOhm
E-bus Current Consumption 450 mA typical
Isolation Voltage 707 V DC (Channel to Bus / Channel to SGND)
Thermal Dissipation 3 W typical
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Enclosure Material Zinc die-cast
Dimensions (W x H x D) 30 mm x 100 mm x 95 mm
Net Weight 350 g
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The ELM3502-0000 is part of Beckhoff’s high-end measurement class. Unlike standard analog slice terminals (such as the EL3356), the ELM3502-0000 provides vastly superior sampling speeds and built-in numerical filters, making it compatible with complex TwinCAT 3 Metrology functions. It requires a compatible EtherCAT Coupler (e.g., EK1100) and proper configuration in TwinCAT for oversampling features.

Application Pitfalls & Engineering Notes

Due to its high sampling rate of 20 ksps, the terminal is sensitive to high-frequency electrical noise and electromagnetic interference. Standard unshielded cabling can distort measurements. Ensure that the metal housing of the ELM3502-0000 makes direct, clean contact with the grounded DIN rail via the grounding springs on the rear panel. When routing signal lines, keep bridge cables separated from high-voltage AC or motor-drive output lines.

Commissioning & Wiring Tips

For quarter-bridge installations, verify that the internal completion resistors are correctly parameterized within the TwinCAT System Manager. Ensure the 6-pin push-in service plug is locked securely in place. If utilizing Distributed Clocks (DC), activate sync managers in TwinCAT to achieve sub-microsecond jitter timing across multiple measurement channels on the network segment.

Installation Guidelines

CRITICAL WARNING: De-energize all power sources feeding the EtherCAT bus and the measurement bridges before physically mounting or wiring the ELM3502-0000. Failure to do so can cause localized ground loops, damage internal calibration tables, or destroy sensitive connected strain gauge sensors.
1

Mount the ELM3502-0000 vertically onto a standard 35 mm DIN rail (EN 60715) with the double slot and key connection securely engaged with adjacent modules.

2

Connect the bridge measurement lines to the 6-pin service plug utilizing standard ferrules or solid conductors with a stripping length of 8 to 9 mm.

3

Ensure the shield of the bridge cable is terminated at the cabinet entry gland plate or connected to a low-impedance ground block nearby.

4

Power on the EtherCAT segment and scan the module in the TwinCAT System Manager to configure the digital filters and sensor calibration properties.

What is the maximum sampling rate of the ELM3502-0000?

The ELM3502-0000 supports dynamic oversampling with high-speed analog acquisition reaching a maximum sampling rate of 20 ksps (50 microseconds) per channel simultaneously.

Which bridge configurations are supported by the ELM3502-0000?

This module fully supports full-bridge, half-bridge, and quarter-bridge resistor structures using 2-wire, 3-wire, 4-wire, 5-wire, or 6-wire connection configurations.

How is the shielding managed on this metrology terminal?

The terminal is encased in a robust zinc die-cast housing designed to provide superior electromagnetic shielding. Grounding is achieved via functional contacts contacting the grounded DIN rail.

Does the ELM3502-0000 have integrated channel-to-channel isolation?

No, it features electrical isolation between the input channels and the internal E-bus / SGND up to 707 V DC, but there is no electrical isolation between the two input channels.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...