Beckhoff ELX1054 EtherCAT Terminal 4-Channel Intrinsically Safe Digital Input Module

Beckhoff ELX1054 EtherCAT Terminal 4-Channel Intrinsically Safe Digital Input Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: ELX1054

  • Negara asal:Jerman

  • Jenis Produk: Intrinsically Safe Digital Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 150 mm x 120 mm x 40 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for intrinsically safe signal acquisition in hazardous environments, the Beckhoff ELX1054 enables direct connection of up to four NAMUR field sensors located in Zone 0 or Zone 20. This compact EtherCAT terminal integrates high-density electrical isolation and comprehensive diagnostic features, allowing process automation plants to transmit field signals to the control level without additional external barriers. By combining intrinsically safe inputs and EtherCAT communication in a single 12 mm housing, it minimizes DIN rail space requirements and simplifies Ex-protection loop design.

Features

  • Hazardous Area Integration: Directly connects Ex i field devices from Zones 0/20 and 1/21 to the EtherCAT network.
  • Standard Compliance: Fully compliant with NAMUR specifications according to IEC 60947-5-6 for reliable sensor status monitoring.
  • Integrated Diagnostics: Continuous monitoring of field circuits for cable breaks (current below 200 uA) and short circuits (current above 6.3 mA).
  • Compact Form Factor: Standard 12 mm terminal housing containing four independent intrinsically safe input channels.
  • High-Speed Communication: Integrates directly with the standard Beckhoff EtherCAT Bus system.

Applications

  • Chemical and petrochemical processing facilities requiring Ex ia classification.
  • Oil and gas storage facilities, pipelines, and custody transfer stations.
  • Pharmaceutical manufacturing plants processing volatile organic compounds.
  • Grain elevators, milling stations, and environments prone to explosive dust (Zone 20/21).

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model ELX1054
Technology Digital Input (Intrinsically Safe, Ex i)
Specification Standard NAMUR (IEC 60947-5-6)
Number of Inputs 4
Connection Method 2-wire
Open Circuit Voltage typ. 8.2 V DC
"0" Signal Current <= 1.2 mA
"1" Signal Current >= 2.1 mA
Switching Hysteresis typ. 200 uA
Short-Circuit Current typ. 7 mA
Fault Detection Limits I <= 200 uA (cable break), I >= 6.3 mA (short circuit)
Max. Switching Frequency typ. 5 kHz (duty factor 50%)
E-Bus Current Consumption typ. 70 mA
Power Contact Current Consumption typ. 15 mA + load
Supply Voltage Electronics 24 V DC (via power contacts from ELX9560 power supply)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Shipping Weight (Calculated) 0.15 kg (Net weight: 55 g)
Package Dimensions (Calculated) 150 mm x 120 mm x 40 mm
Ex Markings ATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
IECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
cFMus: AIS Class I, II, III, Div 1, Groups A-G; Class I, Div 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc

Connections & Interfaces

Terminal Connection Signal Assignment
Input 1 (Ex i) Terminal 1 (+), Terminal 5 (-)
Input 2 (Ex i) Terminal 2 (+), Terminal 6 (-)
Input 3 (Ex i) Terminal 3 (+), Terminal 7 (-)
Input 4 (Ex i) Terminal 4 (+), Terminal 8 (-)

Empirical Engineering Insights

Alternative Models & Compatibility

The ELX1054 is exclusively intended for applications requiring intrinsically safe (Ex i) signal processing. For standard (non-hazardous) applications, the Beckhoff EL1054 or EL1004/EL1008 can be used instead. Note that the ELX series must be fed using the specialized ELX9560 power supply terminal to ensure compliance with the required safety barriers and intrinsic safety standards. Mixing Ex i and non-Ex i modules on the same segment without the appropriate separation barriers (such as the ELX9012 distance terminal) is strictly forbidden.

Application Pitfalls & Engineering Notes

When designing your loop, always ensure that the maximum inductance (Lo) and capacitance (Co) calculations match the Ex-certified values of your NAMUR sensors. Thermal buildup can occur when placing multiple high-density Ex i modules side-by-side. Maintain standard 50 mm clearance above and below the terminal block to allow convection cooling. Failure to supply 24 V DC through the ELX9560 power contacts will cause diagnostic faults on the TwinCAT system, reporting standard E-bus power failure or field-side undervoltage.

Commissioning & Wiring Tips

For wiring connection, use the spring-clamp terminals with standard 2-wire shielded twisted-pair cables. Strip insulation exactly 8 to 9 mm. Ensure that you do not mix the positive and negative terminals of the NAMUR loops, as this can trigger false cable break alarms (current below 200 uA). In TwinCAT 3, use the standard process data objects (PDOs) to monitor status bits for cable break and short circuit diagnostic errors per channel to enable rapid remote troubleshooting.

Installation Guidelines

CRITICAL WARNING: High-voltage danger. Always de-energize the entire control cabinet before inserting, removing, or wiring any ELX-series terminals. Verify complete isolation and measure residual voltages before touching terminal contacts. Failure to strictly follow local Ex-safety regulations and Beckhoff installation codes may cause electrical sparks, risking terminal destruction, explosion in hazardous environments, or severe personal injury.
1

Mount the ELX9560 Ex-power supply terminal onto the 35 mm DIN rail to establish safe power contacts.

2

Slide the ELX1054 terminal into position along the rail guide, engaging the side-by-side double slot and key connection securely.

3

Using a standard flat-head screwdriver, depress the spring-actuation mechanism, insert the stripped NAMUR sensor wires, and release to lock.

4

Establish the correct separation distances between the Ex i intrinsic safety wiring and standard non-intrinsically safe cabling inside the cabinet trunking.

Loading product navigation…

Can standard dry contact switches be connected to this NAMUR input terminal?

Yes, dry contacts can be connected, but they must be configured with appropriate series and parallel resistors to mimic the NAMUR switching thresholds and allow cable break/short-circuit diagnostic detection.

Which power supply is required to power the internal Ex i circuits of this module?

The module requires the Beckhoff ELX9560 power supply terminal to provide the necessary intrinsically safe voltage and current limitation over the power contacts.

How does the module handle fault diagnostics for cable break and short-circuit conditions?

The module continuously monitors the loop current. A current below 200 uA is flagged as a cable break, while current exceeding 6.3 mA is diagnosed as a loop short-circuit.

Can standard EtherCAT terminals be mounted directly next to this Ex i module?

Standard non-Ex i terminals cannot be placed immediately adjacent without an ELX9012 distance terminal to guarantee the required physical segregation between safe and hazardous area circuits.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...