1 daripada 1

Beckhoff IP2301-B520 Fieldbus Box 4-Channel Digital Input/Output Module

Beckhoff IP2301-B520 Fieldbus Box 4-Channel Digital Input/Output Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP2301-B520

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 175 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for direct on-machine deployment without protective enclosures, the Beckhoff IP2301-B520 Fieldbus Box offers high-performance decentralized digital I/O handling on standard DeviceNet networks. By combining four 24 V DC digital inputs with a 3 ms filter and four 0.5 A digital outputs in a single IP67-rated housing, this compact module allows engineers to place field connections closer to automation sensors and actuators. This close-proximity installation strategy significantly cuts down on routing paths, decreases cabling complexity, and simplifies maintenance in harsh washdown or high-vibration environments.

Features

  • DeviceNet Connectivity: Integrated 5-pin M12 bus interface offering automatic baud rate detection up to 500 kbaud.
  • Integrated Digital I/O: Provides 4 digital inputs (24 V DC, Type 2) and 4 digital outputs (24 V DC, 0.5 A per channel) for space-efficient field distribution.
  • Rugged Polyamide Housing: Manufactured from PA6 polyamide, providing physical impact resistance, vibration damping, and an IP65/66/67 environmental protection rating.
  • Output Safety: All 4 output channels are individually short-circuit proof with a typical short-circuit current limit of 1.5 A.
  • Flexible Power Architecture: Separate power loops for control voltage (sensor/logic) and load voltage (actuator/output) allow independent safety-shutdown profiling.

Applications

  • Decentralized assembly automation and robotic end-of-arm tooling.
  • Conveyor systems, packaging machinery, and material handling lines.
  • Food processing machinery requiring high-pressure washdown IP67 ratings.
  • Automotive manufacturing environments featuring distributed DeviceNet architectures.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Beckhoff
Model / Article Number IP2301-B520
Protocol / Fieldbus System DeviceNet (IPxxxx-B52x series)
Data Transfer Rates Auto-detection: 125 kBaud, 250 kBaud, 500 kBaud
Number of Channels 4 Digital Inputs + 4 Digital Outputs
Input Signal Voltage "0" signal: -3 to +5 V | "1" signal: 11 to 30 V (6 mA input current, EN 61131-2 Type 2)
Input Filter Time 3.0 ms
Output Voltage Rating 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof)
Control / Fieldbus Isolation 500 V RMS
I/O Connections M8, screw-type connection
Bus Interface 1 x M12 plug, 5-pin
Power Supply Feed Feed: 1 x M8 male, 4-pin | Downstream: 1 x M8 female, 4-pin
Operating / Storage Temp. 0 to +55 degC / -25 to +85 degC
IP Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Housing Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Housing Material / Weight Polyamide PA6 / Shipping weight: 2 kg

Connections and Interfaces

Connector Type Pin Number Signal Assignment
DeviceNet M12 (5-pin Male) Pin 1 Shield / Functional Earth
Pin 2 V+ (DeviceNet Transceiver Supply 24 V DC)
Pin 3 V- (DeviceNet Transceiver Common Ground)
Pin 4 CAN_H (DeviceNet High Line)
Pin 5 CAN_L (DeviceNet Low Line)
Power Feed M8 (4-pin Male) Pin 1 Feed US (Control Logic / Sensor Supply, 24 V DC)
Pin 2 Feed UP (Load / Output Actuator Supply, 24 V DC)
Pin 3 GND S (Control / Sensor Ground)
Pin 4 GND P (Load Ground)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP2301-B520 belongs to Beckhoff's classic Fieldbus Box series. If upgrading legacy networks or replacing older revisions, note that firmware version dependencies are critical when attempting direct drop-in swaps on older DeviceNet scanners. Configuration parameters are stored on-module and can be parameter-set via explicit DeviceNet messaging or by utilizing Beckhoff's proprietary KS2000 configuration software connected through an RS232 adapter.

Application Pitfalls & Engineering Notes

When cascading auxiliary power (US and UP) through multiple Fieldbus Boxes via the M8 daisy-chain downstream connector, ensure that the cumulative system current does not exceed the absolute 4 A rating of the M8 contact pins. Overloading these pins leads to severe thermal stress inside the polyamide housing, risking permanent seal degradation and communication loss.

Commissioning & Wiring Tips

Always ensure that a standard 121 Ohm terminal resistor is physically situated at the direct endpoints of the DeviceNet trunk line. When completing IP67 assemblies, verify that unused M8 and M12 sockets are sealed with official Beckhoff dust caps (part numbers ZS3000-0010/0020) to prevent moisture ingress. To secure connections without cracking the PA6 threads, torque M8 connections to 0.4 Nm and M12 connections to 0.6 Nm using an industrial torque driver.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Before initiating any hardware mounting, wiring, or pin-configuration procedures, ensure that all main, auxiliary, and network bus power sources have been fully disconnected. High-transient bus signals or accidental shorting of the 24 V DC supply during hot-plugging can permanently damage the DeviceNet transceiver circuitry.

1

Mount the Fieldbus Box using the two 3.5 mm diameter fixing holes on a flat machine base. Use M3 screws tightened to a maximum torque of 0.8 Nm.

2

Connect the DeviceNet cable to the M12 5-pin plug, ensuring the network shielding line is securely connected to functional earth.

3

Interface the M8 4-pin feed cable to configure separate control logic (US) and actuator/load power (UP) lines.

4

Connect sensors and digital actuator components to the M8 terminal channels, checking that individual loads do not exceed the 0.5 A limit.

5

Turn on the 24 V DC power, launch the KS2000 utility or your primary DeviceNet master software, and configure node-addressing mapping.

Loading product navigation…

How is the DeviceNet baud rate configured on the IP2301-B520?

The IP2301-B520 features automatic baud rate detection up to 500 kbaud, conforming itself automatically to the speed defined by the DeviceNet master scanner.

Can the logic and actuator power supplies be separated on this module?

Yes. The M8 4-pin power feed socket isolates control voltage (US for internal electronics and inputs) from load voltage (UP for outputs), allowing safety circuits to cut actuator power independently.

What is the short-circuit protection mechanism on the outputs?

Each of the 4 digital outputs is individually short-circuit proof. When a fault occurs, the channel restricts current to approximately 1.5 A and recovers automatically once the short is cleared.

Does the IP2301-B520 support expansion modules?

No, the IP2301-B520 is a stand-alone Fieldbus Box configuration and does not support additional extension modules on its interface.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...