Decentralized signal acquisition on the factory floor is handled efficiently by the Beckhoff IP2310-B310 Fieldbus Box. This robust distributed I/O module integrates 4 digital inputs and 4 digital outputs directly into a high-speed PROFIBUS DP network without requiring an IP20 protective enclosure. Designed for direct machine-mounting, the device processes rapid digital signals with a 0.2 ms filter constant while offering high protection against environmental moisture and particulates. The Beckhoff IP2310-B310 enables engineers to minimize control cabinet space and drastically reduce field-level wiring complexity by mounting the control interfaces directly on the mechanical structure.

Features

  • PROFIBUS DP Interface: High-performance fieldbus coupling with automatic baud rate detection up to 12 Mbaud.
  • Optimized I/O Density: Configured with 4 digital inputs (24 V DC) and 4 digital outputs (24 V DC, 0.5 A short-circuit protected).
  • Direct Machine Integration: IP67-rated enclosure protects internal components against water jets, dust, and particulate contamination.
  • Compact M8 Connections: Direct physical linkage for industrial sensors and actuators utilizing compact M8 (dia 8 mm) circular plug connectors.
  • Status Diagnostics: Dedicated LED indicators showing fieldbus status, power supply status, and individual channel activity.

Applications

  • Automotive assembly lines and robotic welding cells requiring decentralized tool-tip logic.
  • Conveyor and material handling networks with widely distributed proximity sensors and pneumatic solenoids.
  • Food processing and packaging machines exposed to frequent washdown procedures.

Technical Specifications

Parameter Specification
Manufacturer BECKHOFF
Model Code IP2310-B310
Fieldbus System PROFIBUS DP
Digital Inputs 4 x 24 V DC (Filter: 0.2 ms)
Digital Outputs 4 x 24 V DC (0.5 A per channel, short-circuit proof)
Control Voltage 24 V DC (-15% / +20%)
Sensor Supply Current Max. 0.5 A sum total for all sensors
I/O Connection Method M8 (dia 8 mm) screw-lock / snap-in connectors
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Protection Class IP67
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

M8 Connector Pin Input Port Function Output Port Function
Pin 1 +24 V DC Sensor Supply Not Connected / Reserve
Pin 3 GND (0 V) GND (0 V)
Pin 4 Input Signal (Ch 1 - 4) Output Signal (Ch 1 - 4)

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems, note that the IP2310-B310 uses the PROFIBUS DP standard protocol and relies on specific GSD files (typically I2310B31.gsd) during PLC hardware configuration. If replacing this module with newer EtherCAT-based options like the EP2318-0001, complete changes to the master controller configuration and physical cabling infrastructure are mandatory.

Application Pitfalls & Engineering Notes

Although the output channels are short-circuit protected and rated for 0.5 A each, the total combined current of the module's sensor supplies must not exceed 0.5 A. Deploying multiple high-draw photo-eye sensors without supplementary external distribution blocks will trip the internal thermal fuses. Ensure inductive load suppression (e.g., flyback diodes) is integrated externally when driving high-inductance pneumatic solenoids to prevent premature degradation of the solid-state output circuitry.

Commissioning & Wiring Tips

For robust PROFIBUS communication at rates exceeding 1.5 Mbaud, ensure that both physical ends of the PROFIBUS segment are properly terminated with active 220-ohm pull-up termination resistors. Keep the standard M8 sensor lines under 3 meters to prevent inductive coupling and high-frequency noise interference from adjacent variable frequency drive (VFD) cables.

Installation Guidelines

CRITICAL SAFETY WARNING

Before starting physical mounting, wiring, or maintenance on the PROFIBUS network, isolate all electrical power supplies. Disconnect both the control power (Us) and peripheral load power (Up) channels. Failure to de-energize can lead to accidental actuator actuation or severe communication dropouts due to transient ground loops.

1

Position the module flat against a clean, vibration-resistant machine frame structure. Securely tighten both mounting screws (M4 size) using an appropriate torque limit of 1.2 Nm to guarantee mechanical grounding.

2

Connect the incoming PROFIBUS and local power distribution cabling. Verify that all unused M12 and M8 connector sockets are sealed with official IP67 protective caps to keep out environmental moisture.

3

Adjust the rotary hardware address switches on the front face of the module to align exactly with the assigned node address configured inside your central PLC hardware configuration tool.

Loading product navigation…

What standard GSD configuration file is needed for the IP2310-B310?

This module uses the standard Beckhoff PROFIBUS DP GSD database file, typically named I2310B31.gsd, which allows integration into STEP 7, TIA Portal, or TwinCAT configurations.

How are the sensor power supply limits structured on this module?

The total cumulative current drawn by all connected sensors on the 4 inputs must not exceed 0.5 A. Exceeding this limit triggers internal self-resetting protection circuits.

Can the digital outputs drive inductive loads such as solenoid valves?

Yes, the solid-state outputs are rated up to 0.5 A. However, for highly inductive loads, external freewheeling suppression diodes must be placed across the load to block inductive back-EMF.

What physical connector styles are used for the fieldbus and the I/O?

The digital I/O channels interface via M8 (dia 8 mm) circular connectors. The PROFIBUS DP interface is terminated via standard fieldbus M12 or 9-pin connections depending on the exact box subtype configuration.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...