1 of 1

Danfoss VLT Micro Drive FC-051P4K0T4E 4kW

Danfoss VLT Micro Drive FC-051P4K0T4E 4kW

Only 10 item(s) left in stock
  • Manufacturer: Danfoss

  • Product No.: 132F0026

  • Country of origin:Denmark

  • Product Type: VLT Micro Drive

  • Payment: T/T, Western Union

  • Weight: 5000g

  • Dimensions: 19.4 cm x 9 cm x 23.9 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The 132F0026 (132F0026) is a highly compact and efficient VLT® Micro Drive FC-051, engineered by Danfoss to provide maximum reliability and ease of use in general-purpose motor control applications. Delivering 4.0 kW (5.5 HP) of power, this three-phase frequency converter is optimized for industrial machinery such as conveyors, pumps, and fans where cabinet space is at a premium. Despite its small footprint, the FC-051P4K0T4E is built with heavy-duty components, including coated PCBs and a built-in brake chopper, ensuring high performance and longevity even in demanding environments. Its sophisticated VVC+ control logic provides excellent motor shaft performance, significantly improving process precision and reducing energy waste across the automation lifecycle.

Technical Configuration

The VLT® Micro Drive platform is designed for side-by-side mounting without derating, maximizing panel density. This specific unit operates on a 380 - 480 VAC supply and features an H3 RFI filter, providing high-level electromagnetic compatibility (Class A1/B). A critical hardware advantage is the factory-integrated Brake Chopper, which allows the drive to manage regenerative energy during rapid motor deceleration, protecting the DC link from overvoltage. The inclusion of Coated PCBs (C Option) provides an essential layer of protection against moisture and airborne contaminants, making the 132F0026 a superior choice for industrial settings. The drive supports up to 5 programmable digital inputs and dual analog inputs, allowing for versatile control configurations directly from the terminal block.

Technical Specifications

Feature Specification
Model FC-051P4K0T4E (132F0026)
Brand Danfoss
Power Rating 4.0 kW / 5.5 HP
Mains Voltage 3-Phase 380 - 480 VAC
Output Current 9.0 A
Output Frequency 0 - 200 Hz (VVC+) / 0 - 400 Hz (U/f)
RFI Filter H3 (Class A1/B)
Brake Chopper Integrated (Option B)
Enclosure Rating IP20 / Chassis
Dimensions 194 x 90 x 239 mm
Shipping Weight 5.0 kg

Technical FAQs

Does the 132F0026 include a local control panel (LCP)?

No, this specific code is supplied without an LCP (indicated by the 'X'). For manual operation or local parameter adjustment, a VLT® Control Panel LCP 11 (without potentiometer) or LCP 12 (with potentiometer) must be ordered separately and plugged into the front interface.

What is the benefit of the VVC+ control mode?

VVC+ (Voltage Vector Control Plus) is a Danfoss-patented control principle that ensures the motor develops full torque at low speeds and responds rapidly to load changes. It provides near-servo performance for standard induction motors, enhancing the efficiency of the 4.0 kW output.

Can this drive be mounted horizontally?

For optimal cooling, the drive must be mounted vertically. The IP20 enclosure relies on natural or forced convection through the heatsink. Vertical mounting ensures that the 194 mm height of the unit acts as a chimney, pulling cool air from the bottom and exhausting heat from the top.


Engineering & Installation Guide

  • Brake Resistor Selection: Since this unit features a built-in brake chopper, you can connect an external brake resistor to the BR+ and BR- terminals for applications requiring fast braking or frequent stops. Ensure the resistor value (Ohms) matches the drive’s 4 kW specifications to avoid damaging the internal chopper circuit.

  • PCB Protection & Environment: The coated PCBs in this model offer enhanced resistance to pollution degree 3 environments. However, ensure that the cabinet ventilation is filtered to prevent the buildup of conductive dust on the terminal blocks, which are not coated.

  • Cable Routing: Maintain a minimum distance of 200 mm between the motor cable and the control/signal cables to prevent electromagnetic crosstalk. Use shielded motor cables and ensure the shield is connected to the ground plate at the drive end using a high-frequency (HF) clamp to comply with the H3 RFI filter standards.

 

Key Features:

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Denmark

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...