E82EV302_4B Lenze 8200-Series Vector Frequency Inverter 3.0 kW

E82EV302_4B Lenze 8200-Series Vector Frequency Inverter 3.0 kW

Only 10 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82EV302_4B

  • Country of origin:Jerman

  • Product Type: Variable frequency drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 2900g

  • Dimensions: 24,00cm x 14,00cm x 10,00cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The E82EV302_4B (E82EV302K4B) is a precision-engineered vector frequency inverter from the Lenze 8200-series, designed to provide high-performance speed and torque control for three-phase AC motors. Rated for a power output of 3.0 kW (4.0 HP), this drive is optimized for a 400/500 VAC mains connection, delivering a continuous rated current of 7.2 A with a peak capacity of 9.5 A. A defining feature of the "4B" variant is its integrated interference suppression system, which significantly reduces electromagnetic emissions and ensures compliance with industrial EMC standards without the need for external filtering. This compact, German-manufactured inverter is a critical component for reducing mechanical stress and optimizing energy consumption in applications such as industrial fans, pumps, and conveyor systems. Even in its phase-out status, the E82EV302_4B remains a benchmark for reliability and advanced motor modulation in the B2B sector.

Technical Configuration

The E82EV302_4B utilizes a high-performance vector control architecture that allows for superior dynamic response compared to standard V/f drives. This architecture enables the drive to maintain precise speed and high torque even at low RPM, making it suitable for heavy-start industrial loads. The hardware is designed for control cabinet mounting with a slim "book-style" profile to save rail space. It features a modular expansion slot that supports various plug-in modules for fieldbus communication (e.g., PROFIBUS, CAN, or LECOM) and I/O expansion. Internal safety mechanisms include comprehensive monitoring for earth faults, short circuits, and motor thermal overload (I2t), ensuring the protection of both the inverter power stage and the connected motor.

Technical Specifications

Feature Specification
Model E82EV302_4B / E82EV302K4B
Brand Lenze
Series 8200-Series Vector
Rated Power 3.0 kW (4.0 HP)
Input Voltage 3 Phase 400 / 500 VAC
Rated Output Current 7.2 A (Continuous) / 9.5 A (Peak)
Interference Suppression Integrated / Built-in Filter
Dimensions 24.00 x 14.00 x 10.00 cm
Weight 2.90 kg
Protection Degree IP20
Operating Temp 0 to +45 deg C (Up to 55 deg C with derating)
Product Phase Phase-Out

Technical FAQs

What is the difference between the '4B' and '4C' versions of this drive?

In the Lenze 8200-series nomenclature, both versions share the same voltage class (400/500V). However, the 'B' or 'C' designation often refers to specific hardware revision levels or internal filter characteristics. For the E82EV302_4B, the integrated suppression is optimized for standard industrial environments.

How do I address an 'OC1' (Overcurrent) fault on start-up?

An OC1 fault typically indicates a short circuit in the motor cable or the motor itself, or an excessively fast acceleration ramp. Check the motor insulation and ensure the 'Acceleration Time' parameter is set high enough to accommodate the load's inertia.

Can I run this drive on a single-phase 230V supply?

No. The E82EV302_4B is specifically designed for a 3-phase 400/500 VAC input. Attempting to power it with 230V will result in an 'LU' (Low Undervoltage) trip and the drive will not enable.


Engineering & Installation Guide

  • EMC Grounding: To maximize the effectiveness of the integrated interference suppression, the inverter must be mounted on a conductive, zinc-plated mounting plate. Use a wide-surface grounding strap to connect the drive's PE terminal to the central earthing point of the cabinet to mitigate high-frequency noise.

  • Thermal Clearance: Despite its compact 2.90 kg frame, the power stage generates heat during 3.0 kW operation. Maintain a minimum vertical clearance of 100 mm above and below the unit. Side-by-side mounting is permitted, but ensure that cabinet ambient temperatures do not exceed 45 deg C to avoid automatic current derating.

  • Braking Resistor Connection: For high-inertia loads requiring rapid deceleration, connect an external braking resistor to the +UG and BR terminals. Ensure the resistance value is not lower than the minimum specified in the 8200 Vector manual to prevent damage to the internal brake chopper.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih
Country of origin
Jerman

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...