The EPI1008-0001 (EPI10080001) is a high-performance IO-Link device designed for the decentralized collection of digital input signals in harsh industrial environments. Operating as an IO-Link V1.1 Class A device, this module features 8 digital inputs in a ruggedized, cabinet-free housing with an IP67 protection rating. It is engineered for B2B applications where machine-mount I/O is required to reduce wiring runs and improve diagnostic visibility, such as in robotic assembly lines, food and beverage processing, and modular conveyor systems. By utilizing the IO-Link COM3 high-speed data rate (230.4 kbaud), the EPI1008-0001 ensures rapid signal transmission and comprehensive parameterization capabilities.

Hardware Architecture and IO-Link Integration

The EPI1008-0001 serves as an intelligent bridge between standard binary sensors and an IO-Link Master. The communication interface consists of a single M12 A-coded plug, which carries both the IO-Link data signal and the necessary power supply ($L+$) for the module and connected sensors.

On the field side, the module provides eight M8 screw-type connections. These inputs are compliant with EN 61131-2 Type 3 characteristics, making them highly compatible with modern electronic sensors that require lower power consumption and higher noise immunity. A significant advantage of this module is the adjustable input filter, which can be tuned from 0 to 20 ms via IO-Link parameters to match the specific debouncing requirements of various field devices.

Technical Specifications

Attribute Specification Details
Model EPI1008-0001
Brand BECKHOFF
Protocol IO-Link V1.1 (Class A)
Data Transfer Rate 230.4 kbaud (COM 3)
Number of Inputs 8 Channels
Input Connection M8, screw type
Bus Interface 1 x M12 plug, A-coded
Input Filter 3.0 ms (Default), adjustable 0–20 ms
“1” Signal Voltage 11 to 30 V (Type 3)
Sensor Supply Max 0.5 A total (Short-circuit proof)
Current Consumption Typically 100 mA from L+
Operating Temperature -25 to +60 Celsius
Protection Rating IP65 / IP66 / IP67
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm

Technical FAQs

What is the benefit of the COM3 data rate in the EPI1008-0001?

The COM3 (230.4 kbaud) rate is the fastest IO-Link communication speed available. It minimizes the cycle time for the 8-bit process data image, ensuring that high-speed sensor transitions are captured with minimal latency, which is critical for precision timing in packaging and sorting applications.

Can I connect Class B IO-Link masters to this device?

Yes. As an IO-Link Class A device, the EPI1008-0001 only requires the standard 3-wire connection (L+, L-, and C/Q). It can be connected to a Class B master port, though it will not utilize the additional isolated power pins ($U_A$) provided by Class B.

Is the sensor supply protected against faults?

Yes. The module provides a total of 0.5 A for sensor power, which is derived from the IO-Link $L+$ line. This supply is short-circuit proof, protecting the IO-Link master and the internal electronics of the EPI1008-0001 from field-side wiring errors.


Engineering & Installation Guide

  • M12/M8 Cable Selection: To maintain the IP67 rating, all M12 and M8 connectors must be tightened to the specific torque values (typically 0.4 Nm for M8 and 0.6 Nm for M12). Any unused M8 ports must be sealed with protective caps to prevent moisture or dust ingress.

  • IO-Link Distance Limits: Standard IO-Link specifications limit the cable length between the Master and the EPI1008-0001 to 20 meters. Using high-quality shielded cables is recommended in high-EMC environments to ensure reliable COM3 data transmission.

  • Parameterization: Utilize the IODD (IO-Link Device Description) file in your TwinCAT or third-party engineering tool to configure the input filters. Reducing the filter time below the 3.0 ms default can improve response times but may require shielded sensor leads to prevent nuisance triggers from electrical noise.

Engineering Advantages

The EPI1008-0001 stands out for its extreme durability and high density. The polyamide (PA6) housing is designed to withstand mechanical shock and vibration (conforming to EN 60068-2-6/27), making it suitable for direct mounting on vibrating conveyor frames or robotic arms. By using the IO-Link protocol, engineers gain access to "point-to-point" diagnostics that are impossible with standard digital input blocks, including cable break detection and device identification. This combination of ruggedness and intelligent data makes the EPI1008-0001 a future-proof solution for Industry 4.0 architectures.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Jerman
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...