EPI2338-0002 BECKHOFF 8-Channel Configurable Digital I/O IO-Link Box

EPI2338-0002 BECKHOFF 8-Channel Configurable Digital I/O IO-Link Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EPI2338-0002

  • Country of origin:Jerman

  • Product Type: IO-Link box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The EPI2338-0002 (EPI23380002) is an ultra-versatile IO-Link device that provides 8 digital channels, each of which can be independently configured as either an input or an output. Operating as an IO-Link V1.1 Class B device, it is designed for decentralized, cabinet-free installation in demanding industrial environments. The Class B interface is a critical distinction, as it provides an additional, electrically isolated power supply specifically for high-current loads and outputs. This makes the EPI2338-0002 an ideal B2B solution for modular machine building, robotic tooling, and automated production lines where high I/O density and flexible signal direction are required in an IP67-rated footprint.

Hardware Architecture and Class B Integration

The EPI2338-0002 architecture is defined by its "One-Port-Multi-Signal" capability. Each of the 8 channels, accessed via M12 screw-type connectors, can sink or source signals based on the PLC configuration. The module utilizes the high-speed COM3 (230.4 kbaud) data rate to ensure that the process data for all 16 signals (8 inputs + 8 outputs/diagnostics) is updated with minimal latency.

A key technical feature is the IO-Link Class B interface (M12 A-coded). Unlike Class A, which only provides system power, Class B provides a second, isolated power supply ($P24$). This $P24$ supply powers the digital outputs and the sensor supply, ensuring that an electrical fault or short circuit on the output side does not interrupt the IO-Link communication logic ($L+$). Each output can deliver up to 0.5 A, and the module features an adjustable input filter (0 to 20 ms) to accommodate various field sensor types.

Technical Specifications

Attribute Specification Details
Model EPI2338-0002
Brand BECKHOFF
Protocol IO-Link V1.1 (Class B)
Data Rate 230.4 kbaud (COM 3)
Channel Count 8 (Individually configurable as In/Out)
Interface 1 x M12 plug (A-coded)
I/O Connection M12, screw type
Max Output Current 0.5 A per channel
Input Filter 3.0 ms (Default), adjustable 0–20 ms
Electrical Isolation Yes (L+ system / P24 peripheral)
Operating Temp -25 to +60 Celsius
Protection Rating IP65 / IP66 / IP67
Dimensions (W x H x D) 30 mm x 126 mm x 26.5 mm

Technical FAQs

What is the advantage of a Class B IO-Link port for this module?

The Class B port provides an additional set of pins for auxiliary power ($U_2$ or $P24$). This allows the digital outputs and sensor supply to draw power from an isolated source. If a machine's Emergency Stop cuts the peripheral power ($P24$), the module remains "alive" on the network via the $L+$ system power, allowing it to report the status to the controller.

How is the input/output direction determined?

The direction is determined via the IO-Link parameterization. In the engineering tool (like TwinCAT), the user defines whether a specific pin should act as a Type 3 digital input or a 0.5 A digital output. No hardware jumpers are required.

Does this module support short-circuit diagnostics?

Yes. Every channel is individually short-circuit proof. The module can report short-circuit or overload conditions back to the IO-Link master, enabling precise identification of faulty field wiring or failed actuators.


Engineering & Installation Guide

  • Wiring for IP67: To maintain the environmental seal, M12 connectors should be tightened to a torque of 0.6 Nm. Unused I/O ports must be closed with M12 protective caps. Use high-quality A-coded M12 cables specifically rated for IO-Link Class B to ensure the $P24$ pins are connected.

  • Filter Optimization: For high-speed applications, the input filter can be reduced to 0 ms via IO-Link parameters. However, ensure that the field sensors are high-quality and the cabling is shielded to prevent nuisance triggers from electrical noise.

  • Power Planning: The current consumption from $L+$ (system) is typically 100 mA. Ensure the total load from the 8 outputs does not exceed the capacity of your IO-Link Master's Class B port supply (typically limited by the M12 connector's pin rating).

Engineering Advantages

The EPI2338-0002 represents the pinnacle of I/O flexibility. By allowing each port to be configured on the fly, it significantly simplifies spare parts inventory—one module can replace multiple dedicated input or output boxes. Its Type 3 input characteristics ensure compatibility with low-power sensors, while the 0.5 A outputs are robust enough to drive solenoids, relays, and indicators directly. With its -25 to +60 Celsius operating range and high shock/vibration resistance, the EPI2338-0002 provides a resilient, software-configurable I/O solution for the most modern B2B industrial automation architectures.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Jerman
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...