GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

Hanya 6 item tinggal dalam stok
  • Pengilang: General Electric

  • No. Produk: SR745-W3-P511-G51-HI-R-E

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Transformer Protection System

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 8500g

  • Dimensi: 220 mm x 275 mm x 300 mm (W x H x D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The GE Multilin 745-W3-P511-G51-HI-R-E is a digital, three-winding transformer protection system engineered for the primary protection, management, and control of power transformers. This high-performance device delivers comprehensive multi-winding differential protection, adaptive harmonic restraint, and extensive overcurrent protection elements within a rugged draw-out construction. It features advanced internal logic and precise high-accuracy metering to eliminate the need for extra external components or auxiliary transducers. The unit is configured with 5 A phase current inputs and 5 A ground current inputs across its winding interfaces to match specific system requirements. Outfitted with high-speed processing, comprehensive data logging, and flexible communication ports, the device interfaces seamlessly with distributed control systems (DCS) and SCADA automation architectures to monitor asset health and maintain system integrity.

Features

  • Comprehensive three-winding transformer differential protection with percentage restraint and adaptive harmonic blocking.
  • Draw-out chassis construction allowing quick unit replacement and drastically reduced system maintenance downtime.
  • Integrated high-accuracy metering functions for current, voltage, power, and frequency parameters without auxiliary equipment.
  • Advanced fault diagnostics incorporating precise sequence-of-events reporting, oscillography, and waveform capture.
  • Multiple user-programmable analog and digital inputs/outputs for extensive control and interlocking logic schemes.
  • High-speed communications supporting industrial protocols for integration into SCADA networks.
  • FlexLogic programming capabilities allowing users to customize control sequences and interlocking logic without extra hardware.
  • Front-panel enhanced user interface with an informative LCD screen and tactile keypad for straightforward configuration and diagnostic readout.

Applications

  • Primary protection and control for three-winding power transformers in utility and industrial substations.
  • Main or backup differential and overcurrent protection for auto-transformers and multi-winding generation transformers.
  • Comprehensive asset monitoring, load profiling, and transformer thermal overload tracking in power networks.
  • Advanced power system automation requiring high-speed network reporting and protective relay interlocking.

Ordering Information

Selection Code Technical Specification Description
745 Base model for Transformer Protection System
W3 Three-Winding Transformer Protection
P511 5 A Phase Current Inputs (Winding 1, Winding 2, Winding 3)
G51 5 A Ground Current Inputs (Winding 1, Winding 2)
HI 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz Power Supply
R Red Breaker Closed LED Indicator
E Enhanced Display, Larger LCD, and Improved Keypad

 

Technical Specifications

Parameter Specification
Manufacturer GE Multilin (GE Vernova)
Transformer Windings (W3) 3 Windings
Phase Current Inputs (P511) 5 A for all three windings
Ground Current Inputs (G51) 5 A for Winding 1 and Winding 2
Power Supply Option (HI) 88 – 300 VDC, 70 – 265 VAC @ 48 – 62 Hz
Breaker Status LED (R) Red breaker closed LED indicator
User Interface (E) Enhanced display, larger LCD, and improved keypad layout

Installation Guidelines

  • Chassis Mounting: Securely mount the draw-out chassis into the instrument panel cutout using standard hardware guidelines designated for the unit frame.
  • Grounding Protocols: Connect a dedicated, low-impedance grounding copper wire directly to the chassis ground terminal to mitigate electrical noise and protect sensitive circuitry.
  • Wiring Requirements: Route current transformer (CT) and voltage transformer (VT) connections isolated from low-voltage signal wiring and communication lines to mitigate EMI/RFI issues.
  • CT Circuit Integrity: Ensure all phase and ground current transformer secondary circuits are fully verified and safely terminated to the correct rear blocks prior to operational power-up.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin 745-W3-P511-G51-HI-R-E Transformer Protection System

What is the function of the W3 designation in the relay model code?

The W3 designation specifies that the device is configured to support comprehensive primary differential and overcurrent protection for a three-winding power transformer.

What input current ratings do the P511 and G51 options provide?

The P511 option provides 5 A phase current inputs for all three transformer windings, while the G51 option provides 5 A ground current inputs for Winding 1 and Winding 2.

What source voltage limits are supported by the HI power supply option?

The HI power supply option operates safely over an input range of 88 to 300 VDC and 70 to 265 VAC at a frequency of 48 to 62 Hz.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...