GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

Hanya 3 item tinggal dalam stok
  • Pengilang: General Electric

  • No. Produk: SR750-P5-G5-HI-A20-R

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Feeder Management Relay

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 8500g

  • Dimensi: 220 mm x 275 mm x 300 mm (W x H x D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

GE Vernova Multilin 750 Feeder Management Relay is a digital system intended for the comprehensive management, primary protection, and control of distribution feeders. Designed without automatic recloser functionality to distinguish it from the 760 series, this relay provides robust backup protection for buses, transformers, and transmission lines within a convenient draw-out construction. Equipped with full metering capabilities and analog input/output options, it ensures high asset visibility and integrates into monitoring and control infrastructures.

Description

The GE Multilin 750-P5-G5-HI-A20-R is an industrialized protection system tailored for distribution feeders on solidly grounded, high-impedance grounded, or resonant grounded networks. The unit features dedicated 5 A phase current inputs and 5 A zero-sequence ground current inputs to accommodate specific fault detection profiles. Operating under a wide high-voltage control power range, the relay incorporates an independent eight-channel 4 to 20 mA analog output array alongside a front-panel red breaker closed LED indicator. By utilizing standard industrial protocols and options for serial and Ethernet physical layers, the Multilin 750 executes fast fault processing, interlocking, and status reporting to optimize substation automation and protect upstream transformers and distribution buses.

Features

  • Complete protection suite containing phase, neutral, ground, and negative sequence instantaneous and time overcurrent elements.
  • Comprehensive ground protection capabilities via 5 A zero-sequence ground current inputs paired with neutral and ground overcurrent diagnostics.
  • High-voltage universal power supply options supporting both AC and DC industrial stations.
  • Integrated analog output hardware supplying eight independent 4 to 20 mA channels for remote PLC or SCADA tracking.
  • Standard front panel red LED indicator for distinct local breaker closed status confirmation.
  • Draw-out construction type enabling quick chassis maintenance and minimized replacement downtime.
  • Built-in diagnostic testing system featuring simulation modes to preview fault, pre-fault, and post-fault characteristics.

Applications

  • Primary protection and control for distribution feeders on solidly grounded, high-impedance grounded, or resonant (Peterson Coil) systems.
  • Bus blocking and interlocking protection coordination schemes.
  • High-speed fault detection for arc flash mitigation.
  • Voltage and frequency element-based automatic load shedding schemes.
  • Backup protection for transmission lines, feeders, distribution buses, and power transformers.

Ordering Information

Selection Code Description
750 Base Model: Feeder Management Relay (Without Autoreclose)
P5 Phase Current Inputs: 5 A secondary
G5 Ground Current Inputs: 5 A zero sequence
HI Power Supply: 88 to 300 VDC, 70 to 265 VAC @ 48 to 62 Hz
A20 Analog Outputs: Eight 4 to 20 mA analog outputs
R Breaker Status LED: Red breaker closed LED

 

Technical Specifications

Parameter Specification
Manufacturer GE Vernova
Base Series 750 Series Feeder Management Relay
Phase Current Input (P5) 5 A current transformer (CT) secondary input
Zero Sequence Current Input (G5) 5 A zero sequence current input
Control Power Supply Options (HI) 88 to 300 VDC, or 70 to 265 VAC @ 48 to 62 Hz
Analog Outputs (A20) Eight 4 to 20 mA analog outputs
Breaker Status LED (R) Red breaker closed LED
Phase/Neutral/Ground TOC Pickup Level 0.05 to 20.00 x CT in steps of 0.01
TOC Curve Shapes ANSI Extremely/Very/Moderately/Normally Inverse; Definite Time; IEC Curve A/B/C and Short; FlexCurve A/B; IAC Extreme/Very/Inverse/Short
IOC Delay Accuracy 0 to +20 ms (at non-zero time delay)
Frequency Range 16 to 65 Hz
Frequency Accuracy ±0.02 Hz
Current Metering Accuracy ±0.5% of full scale
Voltage Metering Accuracy 0.25% of full scale

 

Installation Guidelines

  • Mounting: Ensure proper panel mounting alignment matching standard draw-out dimensions. Keep clearance optimized for ventilation.
  • Grounding: Establish a dedicated low-impedance ground connection at the chassis ground terminal before making any current transformer or control power connections.
  • CT Wiring: Verify secure insertion into the automatic shorting terminals. Phase and ground inputs must match the specified 5 A primary or secondary CT ratios to prevent overcurrent saturation or measurement inaccuracies.
  • Control Power Protection: Route lines through an external fuse or circuit breaker matching the HI voltage limits (88 to 300 VDC or 70 to 265 VAC) to avoid power circuit component failure.
  • Shielding: Ground the communication line shields at the PLC or computer side only to prevent ground loop interference.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Vernova Multilin 750-P5-G5-HI-A20-R Feeder Management Relay

What is the primary difference between the 750 and 760 series relays?

The 750 series serves as a feeder management relay without automatic recloser functionality, whereas the 760 series includes a built-in 4-shot recloser mechanism.

What power ranges are supported by the HI control supply designation?

The HI option supports a high-voltage input range of 88 to 300 VDC or 70 to 265 VAC at frequencies between 48 and 62 Hz.

What analog signaling range does the A20 suffix specify for this unit?

The A20 designation equips the device with eight independent 4 to 20 mA analog output channels suitable for standard instrumentation loops.

Can the current transformer inputs accept 1 A secondary ratings directly?

No, the P5 and G5 hardware designations explicitly configure the phase and ground current channels for 5 A secondary current transformer connections.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...