1 daripada 3

Modul I/O Diskret General Electric IS220PDIAH1B Mark VIe

Modul I/O Diskret General Electric IS220PDIAH1B Mark VIe

Hanya 4 item tinggal dalam stok
  • Pengilang: General Electric

  • No. Produk: IS220PDIAH1B

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Pakej I/O

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 650g

  • Dimensi: 130 mm x 130 mm x 85 mm (H x W x D)

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The General Electric IS220PDIAH1B is a Discrete I/O module designed for use within the Mark VIe control system platform. This industrial component operates as a high-reliability interface for discrete input processing in critical control and automation architectures. The IS220PDIAH1B functions in coordination with certified terminal boards to process digital field signals under stringent hardware constraints. The device provides dedicated contact wetting outputs to interface securely with field switches and relay contacts. It is specifically certified for hardware applications deployed in hazardous locations.

Features

  • Dedicated hardware processing for robust industrial discrete signaling.
  • Integrated contact wetting power framework supporting field devices.
  • Intrinsic safety "ic" compatibility when paired with designated accessory terminal boards.
  • Support for multiple field connection block topologies including Euro-style and barrier blocks.
  • Built-in transient voltage limiting mechanisms for reliable voltage regulation.

Applications

  • High-availability industrial automation systems.
  • Power generation and turbine control systems.
  • Critical infrastructure and industrial process control applications.
  • Distributed I/O processing networks in hazardous areas.

Technical Specifications

Parameter Specification
Manufacturer General Electric (GE)
Module Type Discrete I/O Module
System Framework Mark VIe Control System
Power Supply Minimum Voltage 22.5 V dc
Power Supply Nominal Voltage 24.0/28.0 V dc
Power Supply Maximum Voltage 28.6 V dc
Power Supply Maximum Current 0.24 A dc
Contact Inputs Voltage Range 0 to 32 V dc
Contact Wetting Outputs (STCIH1A/H2A/TBCIH2C) 18.5 to 32 V dc, 110 mA dc max
Contact Wetting Outputs 1-21 (STCIH8A/TBCIH4C) 31 V dc max, 10 mA dc max
Contact Wetting Outputs 22-24 (STCIH8A/TBCIH4C) 31 V dc max, 41 mA dc max
Pollution Degree Compatibility Not more than Pollution Degree 2

Connections/Interfaces

Connector/Accessory Terminal Board Terminal Block Type
IS200STCIH1A Euro Style Box-type Terminal Blocks
IS200STCIH2A Euro Style Box-type Terminal Blocks
IS200STCIH8A Euro Style Box-type Terminal Blocks
IS400STCIH1A Euro Style Box-type Terminal Blocks
IS400STCIH2A Euro Style Box-type Terminal Blocks
IS400STCIH8A Euro Style Box-type Terminal Blocks
IS200TBCIH2C Barrier-type Terminal Blocks
IS400TBCIH2C Barrier-type Terminal Blocks
IS200TBCIH4C Barrier-type Terminal Blocks

Installation Guidelines

  • Enclosure Requirements: Install the open-type equipment inside a secure environmental enclosure that requires a tool or key to open.
  • Transient Voltage Regulation: Ensure provisions are implemented to limit power supply transient voltages to less than 140% of the peak rated power supply voltage.
  • Power Limitations: Power must be supplied through a certified power distribution board that limits the available current to 3.5 A maximum.
  • Terminal Wiring: Strip field wiring insulation locally without adding intermediate components other than standard bare conductor replication parts such as ferrules.
  • Wiring Standards: Apply appropriate Class I Division 2 or Zone 2 wiring methods conforming to local codes and authority regulations.
  • Screw Torques (Euro Blocks): Secure connections to a nominal torque of 4 in-lb (0.45 Nm) for wire sizes from 24 AWG to 12 AWG.
  • Screw Torques (Barrier Blocks): Secure connections to a nominal torque of 9.6 in-lb (1.1 Nm) for wire sizes from 22 AWG to 12 AWG.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Modul I/O Diskret General Electric IS220PDIAH1B Mark VIe

What is the maximum current consumption for the device power supply?

The maximum rated current for the module power supply is 0.24 A dc.

Which terminal board accessories are compatible with this module?

Compatible terminal boards include the Euro-style STCIH1A, STCIH2A, STCIH8A, and the barrier-type TBCIH2C and TBCIH4C variants.

What are the torque specifications for the field terminal connections?

Euro Style box-type terminal blocks require a nominal torque of 4 in-lb (0.45 Nm), while Barrier-type terminal blocks require a nominal torque of 9.6 in-lb (1.1 Nm).

What environmental pollution limit applies to this industrial equipment?

The equipment must be operated in an environment that does not exceed a Pollution Degree 2 classification.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Hitam
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...