1 daripada 1

Honeywell 900A16-0101 HC900 Analog Input Hi Level Module

Honeywell 900A16-0101 HC900 Analog Input Hi Level Module

Hanya 3 item tinggal dalam stok
  • Pengilang: Honeywell

  • No. Produk: 900A16-0101

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Analog Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Processing high-level analog signals within industrial automation networks requires reliable, high-density interfaces, which is precisely why the 900A16-0101 was engineered. This high-level analog input module provides 16 isolated channels designed for seamless integration with Honeywell HC900 process controllers. It efficiently monitors and converts analog voltage and current field signals into highly accurate digital data for system processing.

The module features a dedicated analog-to-digital converter, ensuring consistent and rapid update cycles across all channels. With robust point-to-point galvanic isolation and advanced noise rejection characteristics, the 900A16-0101 maintains signal integrity and protects sensitive control system logic from field-side electrical disturbances. This level of reliability makes it a critical component for continuous process control applications where signal precision is vital.

Features

  • 16 isolated high-level input channels to prevent ground loops and signal interference.
  • Supports multiple high-level input signal types including voltage (V) and current (mA).
  • Equipped with a high-resolution 15-bit analog-to-digital converter.
  • Rapid channel update times of 100ms for real-time monitoring.
  • Robust solid-state galvanic isolation rated at 400 VDC point-to-point and 1000 VDC to logic.
  • Superior noise rejection capabilities in both series and common modes.
  • High-impedance inputs minimizing loading effects on field transmitters.

Applications

  • Oil and gas refinery process monitoring.
  • Chemical processing and batch control.
  • Power generation and distribution systems.
  • Water and wastewater treatment facilities.
  • Industrial boiler and combustion control systems.

Technical Specifications

Manufacturer Honeywell
Part Number/Model 900A16-0101
Series HC900 Control System
Module Type Analog Input High Level Module
Number of Channels 16 (Isolated)
Input Types Voltage (V), Current (mA)
Input Impedance >1 megohm for voltage inputs, 250 ohms for current inputs
Galvanic Isolation 400 VDC point-to-point (solid-state switching); 1000 VDC to system logic
A/D Resolution ±15 Bits
Update Rate 100ms
Noise Rejection Series Mode: >31dB, Common Mode: >90dB at 120VAC
Over-range Limit ±10% for linear voltage ranges
Temperature Coefficient ±0.01% of full scale per Celsius maximum
Long-term Stability 0.1% per year
Shipping Weight 2.0 kg

Installation Guidelines

  • Mounting: Mount secure in the designated I/O slot of an HC900 controller rack or remote I/O chassis. Ensure rack power is switched off during insertion or removal.
  • Wiring & Shielding: Use twisted, shielded pair cables for all analog signal runs. Ground the shields at only one end (typically at the controller side) to prevent ground loops.
  • Conduit Layout: Separate low-voltage analog signal cables from high-voltage AC power distribution and motor control lines.
  • Thermal Management: Maintain adequate clearance around the controller rack to ensure convective cooling airflow is not obstructed.
Loading product navigation…

What types of input signals can the Honeywell 900A16-0101 module accept?

The module accepts high-level analog inputs including voltage (V) and current (mA) signals.

How many isolated channels are available on this module?

The 900A16-0101 features 16 isolated high-level analog input channels.

What is the point-to-point isolation rating of the 900A16-0101?

It provides 400 VDC point-to-point solid-state galvanic isolation and 1000 VDC isolation to system logic.

What is the update rate for the analog inputs?

The analog-to-digital converter updates all channels on the module every 100ms.

What is the input impedance of the 900A16-0101?

The input impedance is greater than 1 megohm for voltage inputs and 250 ohms for current (mA) inputs.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...