1 of 6

Lenze E82ZZ22234B210 8200-series Three-Phase RFI Filter

Lenze E82ZZ22234B210 8200-series Three-Phase RFI Filter

Only 8 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82ZZ22234B210

  • Country of origin:Jerman

  • Product Type: Accessories

  • Barcode: 85044086

  • Payment: T/T, Western Union

  • Weight: 980g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description and Application

The E82ZZ22234B210 (E82ZZ22234B210) is a high-performance three-phase radio frequency interference (RFI) filter engineered for integration with the Lenze 8200-series drive systems. This passive component is specifically designed to mitigate high-frequency electromagnetic noise, ensuring compliance with strict electromagnetic compatibility (EMC) standards in industrial environments such as automated manufacturing lines, material handling systems, and pump control stations. By effectively suppressing conducted emissions, the filter prevents interference with sensitive signal controllers and communication networks, significantly reducing unscheduled downtime caused by erratic drive behavior or signal degradation.

Technical Configuration

This hardware unit is designed for a robust industrial electrical profile, operating at a rated voltage of 500 VAC within a frequency bandwidth of 50 to 60 Hz. The device is rated for a continuous current throughput of 7.3 Amperes. Its internal architecture utilizes high-quality inductive and capacitive elements configured to provide optimal attenuation across the frequency spectrum utilized by Variable Frequency Drives (VFDs). The unit is housed in a compact, ruggedized enclosure optimized for heat dissipation in crowded control cabinets. It is intended for direct line-side installation to ensure the incoming power supply remains isolated from the switching noise generated by the inverter power stages.

Technical Specifications

Feature Specification
Model E82ZZ22234B210
Brand Lenze
Series 8200-series
Origin Germany
Rated Voltage 500 VAC
Rated Current 7.3 A
Frequency 50 - 60 Hz
Weight 0.98 kg
Product Status Phase-Out
Commodity Code 85044086

Frequently Asked Questions

Is this filter compatible with all Lenze 8200-series drives?

It is specifically designed for the 8200-series, but compatibility depends on the drive power rating. Verify that the drive current rating does not exceed 7.3 A to ensure the filter operates within its thermal design limits.

Since this is a phase-out model, what should I do for long-term support?

While the E82ZZ22234B210 is in a phase-out stage, original stock remains available for legacy system maintenance. For new designs, consult the Lenze engineering datasheet for current-generation filter equivalents.

What are the primary symptoms of a failing RFI filter?

Common indicators include increased electromagnetic noise causing PLC communication errors, drive trip faults related to voltage spikes, or intermittent sensor signal jitter occurring specifically when the motor drive is active.

Does the orientation of the filter matter during installation?

Yes, for maximum efficiency, the filter must be installed as close to the drive as possible, with shielded cables kept to the shortest possible length between the filter output and the drive input.

Engineering Guidelines and Installation Best Practices

  • Shielding Integrity: When installing the E82ZZ22234B210, ensure the cable shielding from the drive is clamped directly to the common ground or the cabinet backplane with a high-frequency contact clamp. Do not rely on thin "pig-tail" wires for grounding, as these act as antennas for high-frequency noise.

  • Thermal Management: Despite its compact 0.98 kg design, the filter dissipates heat during operation. Maintain a minimum clearance of 50 mm above and below the unit to allow for sufficient air convection. Avoid mounting the filter directly above heat-generating components like braking resistors or reactors.

  • Safety Requirements: Always ensure the supply power is disconnected and verified as zero-energy before commencing installation. Due to the capacitive nature of RFI filters, a residual discharge time of at least 5 minutes after power-down is recommended before handling terminals to prevent electric shock.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu Perak
Country of origin
Jerman

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...