1 daripada 1

Mitsubishi Electric AJ65BT-64RD4 CC-Link Temperature Input Module

Mitsubishi Electric AJ65BT-64RD4 CC-Link Temperature Input Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: AJ65BT-64RD4

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Temperature Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 380g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for high-accuracy thermal monitoring in industrial network environments, the Mitsubishi Electric AJ65BT-64RD4 serves as a specialized 4-channel platinum resistance temperature detector (RTD) input module within the CC-Link remote I/O architecture. This module interfaces with 4-wire Pt100 and JPt100 RTD sensors, converting micro-resistance changes into highly precise digital outputs for PLC integration.

The unit features customizable resolution configurations, outputting either 16-bit signed binary values for standard setups or 32-bit signed binary values for applications requiring precise measurements up to three decimal places. Equipped with photocoupler isolation between the temperature inputs and the main CC-Link transmission lines, the module protects sensitive control circuitry from field-side electrical surges and noise interference.

Features

  • Supports up to 4 independent temperature measurement channels using high-stability 4-wire RTD configurations.
  • Compatible with both Pt100 and JPt100 platinum resistance temperature detectors.
  • Flexible digital output options: 16-bit signed binary (-1800 to 6000) or 32-bit signed binary (-180000 to 600000).
  • Outstanding measurement resolution of 0.025 degC for high-precision thermal tracking.
  • Fast conversion speed of 40 ms per channel, ensuring near real-time thermal response.
  • Secure photocoupler isolation between the measurement terminals and the CC-Link communication bus.

Applications

  • Precision temperature monitoring in chemical processing and petrochemical plants.
  • Environmental chamber and industrial HVAC control.
  • Boiler and furnace thermal loop feedback systems.
  • Process control monitoring in food, beverage, and pharmaceutical manufacturing.

Technical Specifications

CategorySpecification ParameterValue / Details
Product Details Manufacturer Mitsubishi Electric
Part Number / Model AJ65BT-64RD4
Network / Communication Series CC-Link (Remote Device Station, Ver. 1)
Input Specifications Number of Channels 4 channels
Sensor Compatibility Pt100, JPt100 (4-wire type)
Measurement Range -180 to 600 degC
Sensor Detection Output Current 1 mA
Resolution 0.025 degC
Performance & Accuracy Conversion Speed 40 ms / channel
Accuracy (Ambient: 25 ± 5 degC) ±0.1% (with respect to maximum value)
Accuracy (Ambient: <20 degC, >30 degC) ±0.25% (with respect to maximum value)
Electrical & Isolation Power Supply Voltage 24 VDC (18 to 30 VDC allowable)
Current Consumption 0.17 A
Isolation Method Photocoupler isolation (Between input channels and CC-Link; channels are non-isolated from each other)
Withstand Voltage 500 VAC for 1 minute
Physical Characteristics Height 65 mm
Width 151.9 mm
Depth 63 mm
Weight 0.38 kg
Environmental Limits Operating Ambient Temperature 0 to 55 degC
Storage Ambient Temperature -20 to 75 degC
Ambient Operating Humidity 10 to 90% RH (non-condensing)

Connections and Interfaces

Terminal Connection Block Specification / Type Application
Communication & Power Terminal 7-point, 2-piece terminal block (M3.5 screws) CC-Link network cable and 24 VDC unit power supply input
I/O Channel Terminal 27-point, 2-piece terminal block (M3.5 screws) RTD sensor connection (4-wire layout per channel)

Installation Guidelines

  • Mounting: Install within a secure, dust-free control cabinet. Mount securely using integrated DIN rail connectors or direct screw mounting.
  • Wiring: Use CC-Link dedicated high-shield cables for network communication. Ensure the 4-wire RTD signal lines are routed away from high-voltage AC cables to prevent electromagnetic coupling.
  • Grounding: Connect the ground terminal securely to the panel earth ground using a dedicated wire of 2 mm² or larger to assure optimal noise immunity.

Compliance and Certifications

  • Meets IEC 61131-2 specifications for programmable controllers.
  • Conforms to JIS B 3502 vibration and impact resistance standards.
Loading product navigation…

What sensor types are compatible with the AJ65BT-64RD4 temperature input module?

The module is compatible with both Pt100 and JPt100 platinum resistance temperature detectors, utilizing a high-precision 4-wire measurement configuration.

What is the resolution and conversion speed of the AJ65BT-64RD4?

The module delivers a temperature resolution of 0.025 degC with a conversion processing speed of 40 ms per channel.

Are the individual input channels isolated from one another?

While there is reliable photocoupler isolation between the temperature inputs and the primary CC-Link transmission system, the individual measurement channels are non-isolated from each other.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan Platform OpenPLC

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...