1 daripada 1

Mitsubishi Electric FR-A840-00770-2-60 FR-A800 Variable Frequency Drive

Mitsubishi Electric FR-A840-00770-2-60 FR-A800 Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-A840-00770-2-60

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 28000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Speed and torque precision across heavy-duty industrial applications are driven by the Mitsubishi Electric FR-A840-00770-2-60 variable frequency drive. Operating on a 400V class three-phase supply, this high-performance inverter from the premier FR-A800 series delivers optimized motor control utilizing advanced vector regulation algorithms. The unit features standard 3C2 conformal circuit board coating to ensure exceptional reliability in harsh, corrosive environments, paired with an integrated EMC filter (-2 CA designation) to suppress electromagnetic interference.

Features

  • Advanced Real Sensorless Vector (RSV): Achieves high-torque, highly responsive speed control without requiring an external encoder.
  • Multi-Rating Architecture: Supports Super Light Duty (SLD), Light Duty (LD), and Normal Duty (ND) calibration modes to match variable load profiles.
  • Conformal Coating Protection: Circuit boards are treated with 3C2 protective layer (IEC 60721-3-3) to resist humidity, dust, and chemical vapors.
  • Integrated Safety Functionality: Dual-channel emergency stop circuit complying with SIL3 and PL e safety standards.
  • Built-In PLC Programming: Allows users to run custom control algorithms and basic automation sequences directly inside the drive processor.

Applications

  • Continuous material handling and heavy-duty conveyor networks.
  • Industrial hoist, gantry, and crane hoist control systems.
  • Heavy-duty positive displacement pumps and high-pressure extrusion machinery.
  • Automated fan control systems in harsh-environment HVAC and mining operations.

Technical Specifications Table

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FR-A840-00770-2-60
Inverter Series FR-A800 Series
Voltage Class 400 V Class (3-Phase 380V to 500V AC, 50/60Hz)
SLD Rated Current (Super Light Duty) 77 A
LD Rated Current (Light Duty) 62 A
ND Rated Current (Normal Duty) 57 A
Structure & Functionality Standard Model
Circuit Board Coating Conformal Coated (3C2), Non-Plated Conductor
Enclosure Protection Rating IP00 (Open Type)
Cooling Method Forced Air Cooling
Net Weight 23.0 kg
Shipping Weight (Calculated) 28.0 kg
Country of Origin Japan

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-00770-2-60 serves as a direct engineering upgrade for the legacy FR-A740-00770 VFD units. Control parameters and macro programs can be migrated smoothly using Mitsubishi FR Configurator2 software. However, physical terminal block profiles and dimension mounting patterns differ slightly; when retrofitting older enclosures, verify clearance depths and terminal adapter requirements.

Application Pitfalls & Engineering Notes

When utilizing this drive under heavy start-stop cycles (ND ratings), thermal accumulation in the internal transistor modules can accelerate. Always size the enclosure ventilation assuming continuous output dissipation at 40 degC ambient. If operations exceed 40 degC, linear current derating curves must be strictly programmed into the thermal protection parameters.

Commissioning & Wiring Tips

To ensure EMC directive compliance, ensure the internal EMC filter grounding jumper is fully engaged. Grounding should utilize a flat, braided copper ground strap directly bonded to the backplate. Standard round wire conductors can exhibit high impedance to high-frequency carrier-wave noise, leading to phantom faults on nearby low-voltage analog signal lines.

Installation Guidelines

CRITICAL SAFETY WARNING

Risk of electric shock and stored energy hazard. Always de-energize the incoming three-phase supply lines before handling wiring connections. Wait at least 10 minutes post-power down for the DC-bus capacitors to completely discharge. Verify the DC bus voltage reads 0V using a calibrated digital multimeter at the terminal terminals before starting work.

1

Mount the inverter vertically to a rigid, non-flammable vertical backplate inside an industrial panel, ensuring minimum top and bottom clearances of 100mm for optimal convection airflow.

2

Connect the main three-phase AC power input lines to supply terminals R/L1, S/L2, and T/L3. Connect the three-phase motor leads to output terminals U, V, and W.

3

Route low-voltage control signals, analog speed references, and communications through shielded twisted-pair (STP) wiring channels separate from main AC and motor cabling.

4

Perform initial power-up. Navigate the PU keypad controller interface to input fundamental motor parameters, maximum operating frequency, acceleration/deceleration ramps, and designated overload trip values.

Loading product navigation…

What does the -2-60 suffix mean on this model?

The '-2' suffix designates the CA (China/Asia/Europe functional specification) terminal configuration with built-in EMC filter capabilities, and '-60' indicates that the internal circuit board features class 3C2 conformal coating, without silver-plated conductors.

What are the rated output currents for different duty classes on this drive?

The unit is rated for Super Light Duty (SLD) at 77 A, Light Duty (LD) at 62 A, and Normal Duty (ND) at 57 A. Overload capacities vary based on these parameter settings.

Can this inverter run closed-loop vector control?

Yes, but standard closed-loop vector control requires installing an optional plug-in encoder interface card (such as the FR-A8AP) to process encoder feedback signals.

What is the recommended discharging time before servicing?

You must wait at least 10 minutes after disconnecting all primary input power sources to allow the internal DC bus capacitors to drop below hazardous voltage levels.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...