Description

Designed for high-performance industrial motor control, the FR-A840-1.5K-1 by Mitsubishi Electric operates as a premium variable frequency drive within the FR-A800 series. This high-capacity inverter delivers exceptional speed and torque control for 1.5 kW three-phase motors, relying on advanced real-time sensorless vector control algorithms. Built to withstand demanding manufacturing environments, the unit integrates standard serial communication architectures, high-efficiency cooling, and robust overcurrent protection to ensure continuous field operation and minimize plant downtime.

Features

  • Real-time sensorless vector control capabilities for ultra-precise speed and torque response.
  • Built-in RS-485, RS-422, and RS-232 serial communication interfaces supporting Modbus RTU protocols.
  • Dual overload rating tolerance designed for versatile normal duty (ND) and light duty (LD) load characteristics.
  • Embedded safety-related stop function conforming to international industrial standards.
  • Integrated EMC filter to minimize electromagnetic noise and safeguard adjacent control instrumentation.

Applications

  • Material handling conveyor lines requiring precise acceleration and deceleration profiles.
  • Centrifugal pump systems and industrial fan setups utilizing variable torque optimization.
  • Extrusion lines and continuous mixers within chemical and plastics processing facilities.
  • Machine tool spindles requiring stable speed holding under variable mechanical loads.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Reference FR-A840-1.5K-1
Series Name FR-A800
Input Voltage Class Three-phase 400 V (380 to 500 VAC, 50/60 Hz)
Applicable Motor Capacity 1.5 kW
Output Rated Current 4.0 A
Output Rated Capacity 3.0 kVA
Communication Interfaces RS-232, RS-422, RS-485 (Mitsubishi / Modbus RTU)
Standards & Approvals CE, UL, cUL, RoHS
Enclosure Rating IP20
Physical Dimensions (H x W x D) 260 mm x 150 mm x 140 mm
Shipping Weight (Calculated) 4.5 kg

Connections and Interfaces

Terminal Designation Circuit / Function Assignment
R/L1, S/L2, T/L3 Main Three-Phase AC Power Input Connection
U, V, W Three-Phase Variable Frequency Output to Motor
P/+, PR Braking Resistor Connection Terminals
STF / STR Forward Run Start / Reverse Run Start Digital Inputs
SD Common Terminal for Digital Inputs and 24 VDC Power source
2, 4, 5 Analog Frequency Setting Inputs (Voltage / Current) & Common Ground

Alternative Models & Compatibility

The FR-A840-1.5K-1 serves as the direct technological replacement for legacy FR-A740-1.5K series drive models. While the footprint and control terminals line up similarly, please note that parameter structures have expanded. When utilizing FR Configurator2 software to import existing parameter files from A700 series models, a careful verification of acceleration-deceleration curve parameters and motor tuning maps must be performed to ensure smooth commissioning.

Application Pitfalls & Engineering Notes

During integration inside IP54 enclosed control panels, local heat dissipation must be handled correctly. The drive requires a minimum space clear-zone of 50 mm above and below the chassis for unimpeded natural airflow. In applications operating continuously at low speeds under high-torque demand, the integrated motor fan will lose efficiency. Always implement an external forced cooling fan on the motor or utilize inverter-duty rated motors to prevent winding thermal trips (E.THT faults).

Commissioning & Wiring Tips

Ensure that Parameter 79 (Operation Mode Selection) is explicitly set to match your system master. For example, setting Pr.79 to "2" locks control logic exclusively to the external terminals, bypassing the PU keypad. For RS-485 serial communication daisy chains, apply a terminating resistor on the final physical node and run standard double-shielded twisted pair (STP) control cables. The shield must be terminated strictly at a single point (PE ground at the cabinet entry) to prevent destructive ground loops.

Installation Guidelines

CRITICAL WARNING

Isolate all main power lines prior to physical cabinet mounting or control terminal wiring. Once input power is switched off, wait a minimum of 10 minutes for the internal DC bus capacitors to fully discharge. Always measure the DC bus voltage across terminals P/+ and N/- using a calibrated digital multimeter to verify the potential is below 50 VDC before initiating touch-sensitive electrical tasks.

1

Securely mount the variable speed drive on a rigid, vibration-resistant vertical panel backplate using appropriate M5 bolts.

2

Connect the physical PE protective ground terminal directly to the central cabinet earth bar before wiring power supply lines.

3

Terminate the three-phase power lines at R/L1, S/L2, and T/L3, ensuring correct phase configuration, and route the motor outputs from U, V, and W.

4

Secure control signal wiring away from the high-voltage power lines inside separate wire ducting lanes to prevent inductive cross-talk.

Loading product navigation…

What is the rated output current of the FR-A840-1.5K-1 under normal duty conditions?

The rated output current for this model is 4.0 A under Normal Duty (ND) conditions, specifically configured to drive a 1.5 kW induction motor.

Can I run this variable speed drive with a single-phase supply?

No. The drive is designed strictly for three-phase AC power input ranging from 380 to 500 VAC. Attempting to power it on a single-phase line will cause input phase failure trips.

Which communication interfaces are natively integrated into the FR-A840-1.5K-1?

The drive features integrated RS-485, RS-422, and RS-232 serial interfaces, allowing communication using Mitsubishi Electric RTU protocols or standard Modbus RTU.

What is the recommended environmental temperature limit for operating this VFD?

The drive operates reliably at ambient temperatures between -10 degC and +50 degC under non-freezing conditions. Derating is required for ambient temperatures above 50 degC.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...