1 daripada 1

Mitsubishi Electric FR-E540-2.2K-CHT FR-E500 Series Variable Frequency Drive

Mitsubishi Electric FR-E540-2.2K-CHT FR-E500 Series Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-E540-2.2K-CHT

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 3000g

  • Dimensi: 240 mm x 180 mm x 170 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Regulating three-phase AC motors with high precision, the Mitsubishi Electric FR-E540-2.2K-CHT is a compact variable frequency drive engineered for 400V class industrial automation systems. This 2.2 kW inverter delivers reliable speed and torque control, utilizing advanced magnetic flux vector control to optimize motor performance even at low operating frequencies.

Key Features

  • Advanced Magnetic Flux Vector Control: Provides high starting torque and stable low-speed operation for demanding loads.
  • IP40 Protective Construction: The "C" suffix designation indicates an enclosed structure suitable for harsher industrial environments.
  • Integrated PID Controller: Enables closed-loop process control for pressure, flow, and temperature applications without external controllers.
  • Comprehensive Protection Circuits: Built-in safeguards against overcurrent, overvoltage, undervoltage, thermal overload, and short circuits.
  • Multi-Speed Operation: Supports pre-programmed speed profiles via configurable digital inputs.

Industrial Applications

  • Conveyor & Material Handling: Smooth acceleration and deceleration ramps prevent product damage on assembly lines.
  • Pumps & Centrifugal Fans: Energy-saving flow control via variable speed adjustment.
  • Machine Tools: Spindle speed regulation and feed rate control in metalworking and woodworking machinery.
  • Packaging Equipment: Precise speed synchronization for wrapping, sealing, and labeling systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number FR-E540-2.2K-CHT
Series FR-E500 (E540)
Input Voltage Class Three-Phase 380 to 480V AC (+/-10%)
Input Frequency 50/60 Hz (+/-5%)
Output Voltage Three-Phase 380 to 480V AC (cannot exceed input voltage)
Applicable Motor Capacity 2.2 kW (3.0 HP)
Rated Output Current 6.0 A
Protective Structure IP40 (Enclosed Type)
Cooling Method Forced Air Cooling
Operating Ambient Temperature -10 to +50 degC (non-freezing)
Shipping Weight (Calculated) 3.0 kg
Package Dimensions (Calculated) 240 mm x 180 mm x 170 mm

Connections and Interfaces

Terminal / Pin Function / Circuit Assignment
R/L1, S/L2, T/L3 Three-phase AC power supply input
U, V, W Three-phase AC motor output connection
P/+, PR External brake resistor connection terminals
STF Forward rotation start command input
STR Reverse rotation start command input
SD Common terminal for contact input signals
A, B, C Relay output terminals (Fault/Alarm status indication)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-E540-2.2K-CHT is part of the legacy FR-E500 series. When replacing this unit with modern equivalents such as the FR-E740-2.2K or FR-E840-2.2K, verify physical mounting dimensions as newer generations feature a more compact footprint. Parameter sets can be migrated using Mitsubishi's FR Configurator software, though advanced vector parameters may require manual tuning to match the motor characteristics.

Application Pitfalls & Engineering Notes

The IP40 protective enclosure (indicated by the CHT regional variant) limits natural heat dissipation compared to open-chassis IP20 models. Ensure the control cabinet has adequate forced ventilation, maintaining ambient temperatures below 50 degC. Avoid running the drive at carrier frequencies above 14.5 kHz in high-load applications to prevent premature thermal tripping.

Commissioning & Wiring Tips

Always separate control signal wiring from high-voltage motor cables to prevent electromagnetic interference. Ground the motor frame directly to the drive's ground terminal using a thick, braided copper strap. Set parameter Pr. 79 to determine the command source (External, PU, or Combined) before attempting initial commissioning.

Installation Guidelines

CRITICAL WARNING

Risk of electrical shock. De-energize all input power sources before installation or wiring. Wait at least 10 minutes after power-off for the internal DC-link capacitors to discharge completely. Verify DC bus voltage is below 20V DC using a digital multimeter before touching any terminals.

1

Mount the inverter vertically on a flat, non-combustible surface (such as a metal panel) to ensure optimal heat dissipation through the rear heatsink.

2

Maintain a minimum clearance of 50 mm on both sides and 100 mm above and below the unit to allow unobstructed airflow from the cooling fan.

3

Connect the main power lines to R/L1, S/L2, and T/L3. Connect the motor leads to U, V, and W. Do not connect AC power lines to the output terminals, as this will destroy the internal IGBT modules.

4

Ensure the ground terminal is connected to a dedicated class D ground (ground resistance of 100 ohms or less) to minimize electrical noise and ensure safety.

Loading product navigation…

What is the primary difference between the CHT suffix and standard FR-E540 models?

The CHT suffix indicates an IP40 protective construction and specific regional compliance configurations, offering better dust protection than standard IP20 open-chassis models.

Can I use a single-phase input to power this 2.2kW inverter?

No, the FR-E540 series requires a three-phase 380-480V AC input. Running it on single-phase power will trigger an input phase loss fault.

What software is used to program parameters on this drive?

Mitsubishi FR Configurator (or FR-SW1-SETUP-WE) is used for parameter configuration, monitoring, and diagnostics via the PU port.

What is the rated current for the FR-E540-2.2K-CHT?

The drive has a rated output current of 6.0 Amps, suitable for standard three-phase induction motors up to 2.2 kW.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...