1 daripada 1

Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-E840-0230-4-60

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 4800g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to deliver precise speed and torque control for three-phase induction and permanent magnet motors, the Mitsubishi Electric FR-E840-0230-4-60 is a high-performance 400V class variable frequency drive from the FR-E800 series. Featuring a conformal circuit board coating (designated by the -60 suffix), this unit is engineered for enhanced environmental resilience in atmospheres containing conductive dust, moisture, or corrosive gases. It operates with a Normal Duty (ND) rated current of 23.0 A and implements standard source logic (PNP) for its control and safety stop input circuits. The integrated voltage monitoring capability via terminal AM provides real-time operational feedback to supervisory control systems.

Key Features

  • Environmental Protection: Features a robust conformal coating on the internal circuit boards to prevent degradation from atmospheric contaminants.
  • Source Logic Interface: Configured for PNP (source) control input and safety stop signals, facilitating seamless integration with standard safety relays and controllers.
  • Voltage Monitoring: Equipped with an analog voltage output via terminal AM for simple, direct scaling of operational parameters.
  • Flexible Control Options: Supports advanced vector control and auto-tuning protocols for high torque performance at low speeds.

Applications

  • Conveyor and Material Handling Systems: Precise speed synchronization and acceleration profiling.
  • Pumping and Fan Infrastructure: Energy-efficient flow control with built-in PID functionalities.
  • Packaging and Food Processing Machinery: Reliable operation in washdown-adjacent panels thanks to coated PCBs.
  • Compressors and Centrifuges: High-starting torque execution for high-inertia physical loads.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Code FR-E840-0230-4-60
Series FR-E800
Voltage Class 400 V Class (Three-Phase Input)
Inverter ND Rated Current 23.0 A
Rated Frequency 50 Hz (Initial Setting)
Control Logic (Inputs) Source Logic (PNP)
Safety Stop Signal Logic Source Logic (Fixed)
Circuit Board Coating With Conformal Coating (Standard -60)
Plated Conductor Without Plated Conductors
Monitoring Specification Voltage (Terminal AM)
Device Net Weight 4.8 kg
Shipping Weight (Calculated) 7.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The "-60" suffix indicates that this drive is equipped with conformal PCB coating, making it physically interchangeable with standard uncoated FR-E840 models but highly preferred in corrosive or humid environments. Ensure that parameter configurations are cloned using FR Configurator2 software when swapping older FR-E700 series units, keeping in mind the structural differences in wiring terminals.

Application Pitfalls & Engineering Notes

When deploying this drive in dense control enclosures, keep the ambient air temperature under 50 degC. Surpassing this threshold requires appropriate current derating. If the drive is mounted side-by-side with zero clearance, the maximum operating temperature must be derated to 40 degC to avoid thermal overload faults.

Commissioning & Wiring Tips

This model is hard-configured for Source Logic (PNP) operation. When integrating with external controllers, ensure the common terminal connection matches the PNP routing path (typically terminal PC as 24VDC source). Use shielded twisted-pair cables for the AM voltage analog monitoring line to prevent inductive electrical noise from corrupting high-impedance feedback signals.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels remain present in the internal DC bus capacitors even after mains power is disconnected. Disconnect all primary power feeds and verify that the charge LED on the front face of the drive has fully extinguished. Wait a minimum of 10 minutes before touching terminals or physical connections to prevent severe electrical shock.
1
Mount the inverter vertically on a flat, non-flammable backplate, ensuring at least 50mm of clearance at the top and bottom to allow adequate cooling air circulation.
2
Connect the incoming 400V three-phase utility power lines exclusively to terminals L1, L2, and L3. Connection of main power lines to output terminals U, V, or W will destroy the drive.
3
Establish a solid low-impedance ground connection from the drive chassis to the main electrical system protective earth (PE) bus.
4
Ensure control wires are routed away from power cabling to eliminate electromagnetic cross-talk and maintain signal integrity.
Loading product navigation…

What does the -60 suffix in the FR-E840-0230-4-60 part number indicate?

The -60 suffix specifies that the printed circuit board has a conformal coating. This provides essential moisture, chemical, and dust protection for reliable operation in harsh industrial environments.

Can I configure this drive for Sink (NPN) control logic?

No, this specific model (FR-E840-0230-4-60) is hard-configured with Source (PNP) logic for its safety stop inputs and standard digital control terminals.

What is the rated current of this FR-E800 inverter under Normal Duty (ND)?

The unit features a Normal Duty rated output current of 23.0 A, indicated by the '0230' sequence in the model code.

What type of analog monitoring signal is provided by terminal AM?

Terminal AM is configured for analog voltage output monitoring, typically used for scaling speed, current, or voltage feedback to an external controller or meter.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...