Description

Managing up to 80 physical local I/O points, the Mitsubishi Electric FX2N-80MR-DS serves as a high-speed, DC-powered controller within the legacy FX2N micro-PLC architecture. This base unit integrates processing, memory, and high-density input/output control in a single compact chassis. Operating on a nominal 24V DC power supply, it is engineered for field environments where AC mains are unavailable or where battery-backed power systems are mandatory. The platform features 40 digital inputs and 40 relay outputs, providing robust isolation and high switching capacity for diverse industrial actuators and sensors.

Key Features

  • DC Power Infrastructure: Designed to run directly on 24V DC (+20% / -15% ripple), making it highly suitable for mobile machinery, marine installations, and backup-critical systems.
  • Selectable Input Logic: 40 integrated digital inputs configurable as either sink (NPN) or source (PNP) to match existing field sensor topologies.
  • Robust Relay Outputs: 40 electromagnetic relay outputs capable of switching up to 2A per point for both AC and DC load circuits.
  • Processing and Memory: Built-in 16,000-step RAM and EEPROM program memory capacities for complex industrial control algorithms.
  • High-Speed Inputs: Includes integrated high-speed counter phases (up to 60 kHz single-phase, 20 kHz dual-phase) for direct rotary encoder feedback.
  • Expandable Architecture: Fully compatible with FX2N series expansion blocks, special function modules (analog, temperature, positioning), and communication adapters.

Applications

  • Distributed Pump and Valve Control: Ideal for water purification plants and remote pumping stations using direct-current solar array batteries.
  • Material Handling and Conveyor Systems: Provides high I/O density to manage multiple photoelectric sensors, interlocks, and pneumatic solenoid valves.
  • Mobile Equipment Automation: Deployed on utility vehicles, marine vessels, and heavy transport equipment where the onboard supply is strictly 24V DC.
  • Auxiliary Packaging Machinery: Performs rapid logic control for sealing, cutting, and wrapping stations requiring isolated relay operations.

Technical Specifications Table

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Reference FX2N-80MR-DS
Product Series MELSEC FX2N Series
Operating Voltage 24V DC (+20% / -15%)
Total I/O Points 80 Points
Digital Inputs 40 Points (24V DC, Sink/Source)
Digital Outputs 40 Points (Relay, isolated)
Max. Relay Load Current 2A per point; 8A per group (4 points); 30V DC / 240V AC max.
Program Memory 16,000 steps (RAM/EEPROM internal or optional cassette)
Response Time Inputs: approx. 10 ms; Outputs: approx. 10 ms (relay mechanical lag)
Internal Current Consumption 40W (Maximum power consumption)
Country of Origin Japan
Shipping Weight (Calculated) 1.45 kg
Package Dimensions (Calculated) 310 mm x 115 mm x 110 mm

Connections and Interfaces

Terminal Designation Function / Connection Specification
+ / - (Power) Primary 24V DC input supply terminals.
S / S Terminal Input common terminal. Connect to 24V for Sink (NPN) configuration or 0V for Source (PNP) configuration.
X000 to X047 40 channel digital inputs. X000 to X005 are high-speed counter compatible.
COM0 to COM7 Common return terminals for isolated relay output groups.
Y000 to Y047 40 channel physical relay contacts. External circuit fuses should be matched to load groupings.

Empirical Engineering Insights

Alternative Models & Compatibility

The FX2N-80MR-DS is an older classic micro-PLC architecture. If you are retrofitting or replacing an older FX2-80MR-D, the FX2N model offers equivalent physical spacing but operates with substantially faster processing speeds and a larger instruction library. For modern migrations, note that the FX2N range is superseded by the MELSEC iQ-F (FX5U) series. Upgrading to an FX5U-80MR/DS requires an FX5-CNV-BUS bus conversion module to retain any downstream legacy FX2N expansion units.

Application Pitfalls & Engineering Notes

Relay wear is the most common failure vector for this device in high-duty environments. When driving inductive loads (such as DC solenoid valves or motor contactor coils), you must install an external flyback diode (for DC loads) or an RC snubber circuit (for AC loads) across the load. Failure to do so will cause contact arcing, degrading the internal relays and leading to premature weld-shut failures. Maintain clear ventilation space around the PLC; ambient operating temperatures inside the panel must not exceed 55 degC.

Commissioning & Wiring Tips

Ensure the S/S (Sink/Source) terminal is tied directly to the correct reference voltage before powering the unit. Leaving this floating will result in digital inputs failing to register. If routing encoder lines into X000 through X005, use high-quality twisted pair shielded cabling and terminate the shield at a single point near the panel ground bar to suppress high-frequency EMI.

Installation Guidelines

CRITICAL WARNING: Verify that all 24V DC incoming lines and field-side AC/DC load circuits are fully de-energized prior to terminal connection or chassis installation. Under no circumstances should live terminal blocks be wired. Failure to comply may damage sensitive logic components and cause physical injury.
  1. 1 Mount the base unit onto a standard 35mm DIN rail horizontally. Ensure the top and bottom ventilation slits are not obstructed by adjacent wiring trunks or metal enclosures.
  2. 2 Connect a dedicated system ground wire from the Functional Earth (FE) terminal on the PLC to a low-impedance copper ground bus.
  3. 3 Wire the 24V DC supply lines to the '+' and '-' terminals using cross-sections of at least 1.25 mm2 (AWG 16).
  4. 4 Double-check your Sink/Source configuration by verifying the link on the S/S terminal before energizing the control cabinet.
Loading product navigation…

What is the primary difference between the DS and ES versions of this PLC?

The 'DS' suffix indicates a 24V DC input power supply with relay outputs, whereas the 'ES' version operates on an 85-264V AC power supply.

Can I mix Sink and Source inputs on the same FX2N-80MR-DS controller?

No, because all 40 input channels share a common S/S terminal. The selection of Sink or Source is group-wide depending on how the S/S terminal is connected.

What is the expected mechanical lifespan of the output relays?

The internal relay contacts are rated for approximately 10,000,000 mechanical operations. Under maximum inductive load switching (2A), the electrical lifecycle is typically 100,000 cycles, emphasizing the need for external surge suppressors.

How do I upgrade an existing program to a modern FX5U replacement controller?

You can use GX Works3 to open the legacy GX Developer FX2N program, which will automatically convert the logic to the FX5U format, though some instruction sets and physical hardware configurations require manual adjustments.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...