1 daripada 1

Mitsubishi Electric L06CPU-P MELSEC L Series CPU Module

Mitsubishi Electric L06CPU-P MELSEC L Series CPU Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: L06CPU-P

  • Negara asal:Amerika Syarikat

  • Jenis Produk: CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 3000g

  • Dimensi: 90 mm x 28.5 mm x 95 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Optimizing compact control architectures with high-speed execution, the Mitsubishi Electric L06CPU-P serves as a highly capable central processing unit within the rack-free MELSEC L Series family. This controller integrates built-in digital inputs and outputs directly on the CPU body, configured specifically for PNP (source) switching logic. Designed with a program capacity of 240K bytes (approximately 60K steps), it manages sophisticated control tasks while offering onboard Ethernet, USB, and SD/SDHC card interfaces. The module eliminates the physical constraints of traditional backplanes, mounting directly to a standard DIN rail and connecting via lateral bus connectors for modular expansion.

Features

  • PNP Output Configuration: Integrated 24-point I/O block featuring 16 digital inputs and 8 transistor outputs utilizing source (PNP) logic.
  • Onboard Communications: Dedicated RJ45 Ethernet port supporting MC Protocol and Modbus/TCP, paired with a Mini-USB port for programming.
  • Flexible Data Storage: Integrated SD/SDHC memory card slot for data logging, firmware updates, and comprehensive parameter backup.
  • High-Speed Processing: Achieves basic instruction execution times of 9.5 ns for sequence instructions, ensuring fast program scans.
  • Rack-Free Modular Design: Direct-mount DIN-rail installation with side-by-side connector coupling simplifies cabinet layouts.

Applications

  • Packaging Machinery: Executing registration control, high-speed counting, and positioning profiles on compact packaging lines.
  • Conveyor and Material Handling: Localized routing, sorting, and lifter controls utilizing integrated PNP sensor networks.
  • Water Treatment Subsystems: Standalone pump station controllers requiring native Ethernet communications and compact foot-prints.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Number L06CPU-P
Control Series MELSEC L Series
Program Memory 240K bytes (60K steps)
Standard RAM 768K bytes
Standard ROM 1024K bytes
Built-In I/O Points 24 points total (16 Inputs / 8 Outputs)
Output Switching Logic Transistor (Source / PNP)
Basic Processing Speed 9.5 ns (LD Instruction)
Internal Current Consumption (5 VDC) 0.65 A
Operating Temperature Range 0 to 55 degC
Shipping Weight (Calculated) 3.0 kg (with protective packaging)
Unit Dimensions 90 mm x 28.5 mm x 95 mm

Connections and Interfaces

Interface / Connection Technical Assignment
RJ45 Ethernet Port 10BASE-T/100BASE-TX communication (MC Protocol, TCP/IP, UDP)
USB Port Mini-B female connector for high-speed GX Works2 programming link
Built-In I/O Connector 40-pin high-density connector for 24 VDC PNP digital input/output wiring
SD Card Slot Supports standard SD and SDHC memory cards up to 32 GB

Alternative Models & Compatibility

The L06CPU-P is the source-type counterpart to the standard L06CPU, which relies on sink (NPN) transistor outputs. Substituting one for the other requires careful verification of field sensor wiring and polarity. If scaling program parameters or requiring larger data tables, consider migrating to the L26CPU-P, which doubles step execution capabilities while remaining completely compatible with the same lateral extension bus modules.

Application Pitfalls & Engineering Notes

When utilizing the integrated high-speed counters built into the I/O block, ensure the signal rise and fall times do not exceed the configured response filter. High electrical noise in proximity to the I/O cables can cause miscounts. Always route I/O lines separate from high-voltage AC cables. In fully enclosed control panels with limited air circulation, note that continuous high-speed switching across all 8 output channels simultaneously can raise module temperature; verify that panel ambient temperatures remain below 55 degC.

Commissioning & Wiring Tips

To communicate with the CPU over Ethernet, ensure the programming laptop resides on the same subnet as the default CPU IP address or utilize the direct-connection search tool within GX Works2. When terminating the 40-pin I/O connector, apply a separate, regulated external 24 VDC power supply to the designated common terminals to isolate the CPU backplane logic from potential field wiring short-circuits.

Installation Guidelines

CRITICAL WARNING: Ensure all external AC and DC power supplies feed-into the panel are completely de-energized before mounting, removing, or wiring the CPU module. Failing to isolate power can cause immediate permanent damage to the CPU's internal ASIC communication layer and risk personal safety.
1
Align the CPU module on the standard 35 mm DIN rail, then push the unit firmly until the lower locking tab clicks into place.
2
Slide the expansion bus connector cover sideways and attach the neighboring power supply module or expansion unit, ensuring the connector locks engage completely.
3
Connect the functional ground terminal of the adjacent power supply module to the central cabinet ground bus using a short, low-impedance conductor.
Loading product navigation…

What is the key electrical difference between this model and the standard L06CPU?

This model features a built-in digital output block configured for PNP (source) switching logic, whereas the standard model uses NPN (sink) transistor outputs.

Can this CPU be mounted to a standard PLC rack or chassis?

No. The MELSEC L Series uses a rack-free modular design. Units mount directly to standard 35 mm DIN rails and connect side-by-side using integrated bus connectors.

Which software is required to program this control module?

Programming, configuration, and diagnostics are performed using Mitsubishi's GX Works2 or GX Works3 software environments.

What is the default memory capacity for user programs on this module?

The CPU contains 240K bytes of program memory, which translates to approximately 60,000 steps of ladder or SFC code.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...