1 daripada 1

Mitsubishi Electric QJ71GF11-T2 CC-Link IE Field Master Module

Mitsubishi Electric QJ71GF11-T2 CC-Link IE Field Master Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: QJ71GF11-T2

  • Negara asal:Amerika Syarikat

  • Jenis Produk: CC-Link Communication Modules

  • Pembayaran: T/T, Western Union

  • Berat: 180g

  • Dimensi: 27.4 mm x 98 mm x 115 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Integrating seamlessly into high-speed industrial networks, the QJ71GF11-T2 serves as a high-performance communication interface within the MELSEC-Q automation platform. This module enables deterministic, high-capacity data exchange by functioning as either a master or local station on a CC-Link IE Field network. Operating at a transmission speed of 1 Gbps, it manages extensive digital and analog I/O points across distributed automation architectures, ensuring synchronized control and rapid diagnostic capabilities.

The unit supports versatile physical layouts including line, star, and ring network topologies, which can be combined to suit complex factory floor environments. Its integration within the MELSEC-Q series allows for straightforward configuration via GX Works software, reducing engineering overhead and optimizing data throughput for heavy industrial processing.

Features

  • High-Speed Communication: Operates at a physical layer speed of 1 Gbps for rapid data transmission.
  • Flexible Topologies: Supports line, star, and ring network configurations, including hybrid line/star systems.
  • Dual-Role Capability: Configurable as either a network Master Station or a Local Station.
  • Token Passing Method: Implements a deterministic token-passing communication scheme to prevent network collisions.
  • Massive Data Capacity: Handles up to 16,384 RX/RY points and 8,192 RWr/RWw words per network.
  • Extended Distances: Supports up to 100 meters between stations and up to 12,100 meters total loop distance in ring configurations.

Applications

  • Automotive assembly and robotic welding lines
  • High-speed packaging and sorting machinery
  • Water and wastewater treatment distribution systems
  • Material handling and automated warehousing systems
  • Distributed PLC-to-PLC communication links in processing plants

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model QJ71GF11-T2
Module Type CC-Link IE Field Network Master/Local Module
Communication Speed 1 Gbps
Station Types Master Station, Local Station
Communication Method Token passing method
Maximum RX Points 16,384 points
Maximum RY Points 16,384 points
Maximum RWr Points 8,192 points
Maximum RWw Points 8,192 points
Connection Cable Type Category 5e or higher (Double-shielded, STP) straight cable
Max Station-to-Station Distance 100 m (Compliant with ANSI/TIA/EIA-568-B Category 5e)
Max Total Distance (Line) 12,000 m (1 master and 120 slave stations)
Max Total Distance (Ring) 12,100 m (1 master and 120 slave stations)
Occupied I/O Points 32 points (I/O assignment: Intelligent 32 points)
Internal Current Consumption (5 VDC) 0.85 A
Dimensions (W x H x D) 27.4 mm x 98 mm x 115 mm
Weight 0.18 kg

Connections and Interfaces

Port Label Connector Type Functional Description
PORT1 RJ45 Primary CC-Link IE Field connection port (1000BASE-T)
PORT2 RJ45 Secondary CC-Link IE Field connection port for ring, line, or star daisy-chaining

Installation Guidelines

  • Mounting: Place the module into the standard slot of a MELSEC-Q series main or extension base unit. Secure the unit with the module fixing screw to prevent vibration-induced disconnections.
  • Cabling Requirements: Use only double-shielded, Category 5e or higher STP straight cables. Standard unshielded twisted pair (UTP) cables should not be used due to noise sensitivity at 1 Gbps speeds.
  • Noise Abatement: Route communication cables away from high-voltage cables and motor drive lines by a minimum of 100 mm to avoid electromagnetic interference.
  • Grounding: Ensure the base unit's functional ground (FG) terminal is connected to a dedicated class D ground (grounding resistance of 100 ohms or less).
Loading product navigation…

Can the QJ71GF11-T2 module be used in a CC-Link IE Control network?

No. The QJ71GF11-T2 is designed specifically for CC-Link IE Field networks and is not compatible with CC-Link IE Control networks.

Does this module support star topologies, and are hubs required?

Yes, star topologies are supported. When building a star topology, a compatible industrial switching hub (1000BASE-T compliant) is required.

What happens if a cable breaks in a ring topology setup?

In a ring topology configuration, the network will automatically perform a loopback function to keep communication active among the remaining operational stations.

How many I/O points does the QJ71GF11-T2 occupy on the PLC base unit?

The module occupies 32 points, configured as an Intelligent module within the PLC I/O assignment settings.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...