1 daripada 1

Omron 3G3MX2-A4055-ZV1 MX2 Series Multi-Function Compact Inverter

Omron 3G3MX2-A4055-ZV1 MX2 Series Multi-Function Compact Inverter

Hanya 2 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: 3G3MX2-A4055-ZV1

  • Negara asal:Jepun

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 6000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Optimized speed and torque regulation in heavy-duty automated machinery is achieved through the integration of the Omron 3G3MX2-A4055-ZV1 variable frequency drive. Representing the highly modular and compact MX2 Series, this industrial inverter is engineered to deliver dynamic three-phase 400 V AC motor control up to a capacity of 5.5 kW. With its integrated functional safety architecture and advanced vector control algorithms, the drive ensures stable performance under high starting torque demands, adapting seamlessly to complex machine environments.

Features

  • Advanced open-loop current vector control providing 200% starting torque at frequencies as low as 0.5 Hz.
  • Dual safety inputs (S1 and S2) conforming to ISO13849-1 Cat. 3 / PLd standards for integrated Safe Torque Off (STO) functions.
  • Built-in Modbus RTU communication over a standard RS-485 interface for easy network configuration.
  • Robust IP10-rated enclosure design optimized for internal panel mounting and space-saving side-by-side layout.
  • Integrated drive programming platform allows execution of custom logical sequences and decentralized control.

Applications

  • High-torque material handling conveyor lines and automated sorting equipment.
  • Industrial fans, centrifugal air blowers, and positive displacement fluid pumps.
  • Processing machinery including industrial mixers, small extruders, and rotary packaging tools.

Technical Specifications Table

Specification Parameter Value / Rating
Manufacturer Omron
Model Number 3G3MX2-A4055-ZV1
Series Name MX2 Series Multi-Function Compact Inverter
Input Voltage Class 3-Phase 380 to 480 V AC (+10% / -15%), 50/60 Hz
Max Applicable Motor Capacity (CT) 5.5 kW (Heavy Duty)
Enclosure Rating IP10 Minimum (Panel-mounting)
Communication Interface Modbus RTU (via built-in RJ45 physical layer)
Safety Standard ISO13849-1 Cat. 3 / PLd Compliant
Net Weight 3.5 kg
Shipping Weight (Calculated) 6.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The "ZV1" designation in the model number marks the standardized firmware revision equipped with permanent magnet (PM) motor vector control capability alongside induction motor control. This unit acts as a physical drop-in replacement for older non-ZV1 variants of the same 5.5 kW power frame size, though parameter mappings for safety loop configurations must be verified during system retrofit procedures.

Application Pitfalls & Engineering Notes

During heavy-load, continuous duty operations, avoid placing the inverter in unventilated enclosures where internal temperatures exceed 40 degC without systematic derating. Maintaining a minimum clearance of 100mm both above and below the cooling heatsink is mandatory to prevent thermal trip warnings under sustained load profiles.

Commissioning & Wiring Tips

When setting up the Safe Torque Off (STO) circuit, ensure that the safety jumper between standard terminal ports is removed before wiring to external safety relays. It is highly recommended to run the motor feed cables through shielded conduits separated from low-level control and feedback signals to eliminate high-frequency electromagnetic interference.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE

Disconnect all primary power sources and verify zero potential across the DC bus terminals prior to initiating installation or maintenance. Wait a minimum of 10 minutes post-power de-energization to allow internal capacitors to safely discharge stored electrical charge.

1
Mechanical Mounting: Securely mount the chassis vertically inside an electrical cabinet. Retain standard side gaps if mounting multiple inverters side-by-side.
2
Power Terminals Connection: Wire the three-phase 400 V AC supply to terminals L1, L2, and L3. Connect the output motor leads directly to terminals U, V, and W. Ensure a solid, low-impedance ground connection.
3
Control and Safety Integration: Route external control signals through the dedicated terminal strip, keeping signal and safety-loop lines properly shielded and separated from the high-power input/output runs.

What does the ZV1 suffix signify on the 3G3MX2-A4055-ZV1?

The ZV1 suffix indicates the upgraded model version with enhanced firmware, which includes built-in functional safety compliant with ISO13849-1 and expanded motor support including permanent magnet synchronous motors.

How long should I wait after powering down before opening the wiring terminal covers?

You must wait at least 10 minutes to allow the DC bus capacitors to discharge to a safe voltage level. Always verify with a digital multimeter that no residual voltage remains.

Can this inverter run 3-phase motors on single-phase input power?

No, this specific model is a 400 V class 3-phase input model designed strictly for three-phase power grids. Attempting to run it on single-phase input may trigger immediate phase-loss faults.

What communication protocols are natively supported by this unit?

It features an integrated Modbus RTU protocol interface over RS-485. Optional fieldbus option units can be fitted for EtherCAT, CompoNet, and DeviceNet systems.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...