1 daripada 1

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

Omron CJ1W-AD081-V1 CJ1 Series Analog Input Unit

Hanya 3 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: CJ1W AD081-V1

  • Negara asal:Jepun

  • Jenis Produk: Analog Input Modules

  • Pembayaran: T/T, Western Union

  • Berat: 150g

  • Dimensi: 31 mm x 90 mm x 89 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

For high-density process data acquisition in industrial environments, the CJ1W-AD081-V1 serves as a reliable multi-channel analog input unit within the Sysmac CJ-series PLC platform. This module supports up to eight analog input channels on a single slot, making it highly efficient for cabinets with limited footprint. It interfaces directly with CJ1, CJ2, and compatible CPU racks via the system bus, facilitating rapid data transfers and streamlined diagnostic monitoring.

Each channel can be independently configured for different input signal types, allowing engineers to mix voltage and current signals on the same physical module. Key processing functions integrated directly into the hardware include scaling, peak hold, mean value processing, and input wire-disconnection detection, which reduces the computational load on the main CPU.

Features

  • Supports up to 8 analog input channels in a compact single-slot width.
  • Independently configurable inputs for voltage (1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V) and current (4 to 20 mA).
  • High-speed conversion rate of 250 microseconds per point (2 milliseconds total for all 8 points).
  • High-resolution conversion mode up to 1/8000 (standard mode is 1/4000) for precise application control.
  • Built-in digital filter function to suppress high-frequency process noise.
  • Peak hold and valley hold functions for tracking transient process limits.
  • Disconnection detection feature for 1 to 5 V and 4 to 20 mA input signals.

Applications

  • Multi-zone temperature tracking and monitoring in thermal processing.
  • Flow rate, level, and pressure transmitter integration in water treatment systems.
  • Feedback control loops in plastic extrusion and chemical dosing machinery.
  • Factory automation and process monitoring systems requiring high-density analog acquisition.

Technical Specifications

ManufacturerPart Number/ModelSeriesModule TypeNumber of InputsInput Ranges (Voltage)Input Ranges (Current)Input Impedance (Voltage)Input Impedance (Current)ResolutionConversion SpeedAccuracy (at 25 degC)IsolationExternal ConnectionsCurrent ConsumptionDimensionsWeightOperating Temperature
Omron
CJ1W-AD081-V1
CJ Series (CJ1, CJ2)
Analog Input Unit (Special I/O Unit)
8 points
1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V
4 to 20 mA
1 MOhm minimum
250 Ohm rated resistance
1/4000 (standard mode), 1/8000 (high-resolution mode)
250 microseconds/point max.
Voltage: +/-0.2% of F.S. | Current: +/-0.4% of F.S.
Photocoupler isolation between input terminals and PLC internal bus (no isolation between individual input channels)
18-point terminal block (detachable)
420 mA max. at 5 VDC (supplied via backplane)
31 mm x 90 mm x 89 mm (W x H x D)
150 g (excluding shipping packaging)
0 to 55 degC

Connections and Interfaces

The unit features an 18-point detachable terminal block. Users can pre-wire the block before attaching it to the module. Terminal mappings should follow standard instrumentation wiring layouts:

Terminal Pair Signal Designation Description
A1 / B1 V IN 1 / I IN 1 Input 1 Voltage (+) / Input 1 Current (+)
A2 / B2 COM 1 Input 1 Common (-)
A3 / B3 V IN 2 / I IN 2 Input 2 Voltage (+) / Input 2 Current (+)
A4 / B4 COM 2 Input 2 Common (-)
A5 / B5 V IN 3 / I IN 3 Input 3 Voltage (+) / Input 3 Current (+)
A6 / B6 COM 3 Input 3 Common (-)
A7 / B7 V IN 4 / I IN 4 Input 4 Voltage (+) / Input 4 Current (+)
A8 / B8 COM 4 Input 4 Common (-)
A9 / B9 NC / SLD No Connection / Shield Ground Terminal

Note: Terminals A10 through B18 follow a repeating functional layout for Inputs 5 through 8. When using current inputs, short-circuit the voltage input (V IN) and current input (I IN) terminals for that channel.

Installation Guidelines

  • Always switch off the PLC system power supply before mounting or removing the module from the rack.
  • Ensure the slide locks on the top and bottom of the unit are securely locked into the adjacent modules.
  • To prevent electromagnetic interference, use shielded twisted-pair (STP) cables for all analog signal runs.
  • Route analog I/O wiring separately from high-voltage, high-current AC power cables.
  • Connect the shield wire of the input cables to the shield terminal (SLD) or ground them at the panel entry point.

Compliance and Certifications

  • CE Mark Directive compliant
  • UL and cULus listed
  • Lloyd's Register approved for marine installations
Loading product navigation…

What is the conversion speed of the CJ1W-AD081-V1?

The module features a fast conversion speed of 250 microseconds per point, meaning all 8 channels can be processed in 2 milliseconds.

Can I mix voltage and current input signals on the same CJ1W-AD081-V1 unit?

Yes. Each of the 8 channels can be configured independently for voltage or current input types using the PLC software settings.

How do I wire a current input channel instead of a voltage input?

To configure a channel for current input (4 to 20 mA), you must short-circuit the Voltage Input (V IN) and Current Input (I IN) terminals for that specific channel, then connect the signal source to these combined terminals and the common (COM) terminal.

Does this module require an external power supply?

No. The CJ1W-AD081-V1 draws its operational power directly from the 5 VDC internal bus of the CJ-series PLC backplane.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...