1 daripada 1

ProSoft PLX31-EIP-MBS4 Serial Four-Port Communication Gateway

ProSoft PLX31-EIP-MBS4 Serial Four-Port Communication Gateway

Hanya 10 item tinggal dalam stok
  • Pengilang: ProSoft

  • No. Produk: PLX31-EIP-MBS4

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Communication Gateways

  • Pembayaran: T/T, Western Union

  • Berat: 3000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The PLX31-EIP-MBS4 is an industrial-grade communication gateway designed to establish bi-directional data exchange between EtherNet/IP networks and Modbus Serial protocols. By acting as a protocol converter, this module permits EtherNet/IP-enabled controllers, such as Rockwell Automation Logix processors, to seamlessly read and write data to Modbus Serial devices. The gateway features four isolated serial ports, allowing independent configuration for RS-232, RS-422, or RS-485 electrical interfaces. This flexibility enables high-density integration of field instruments, power meters, drives, and flow controllers into modern control systems.

Engineered for demanding industrial environments, this interface module supports both EtherNet/IP Class 1 I/O connections for real-time control and Class 3 messaging for diagnostic data transfer. The dynamic data mapping capabilities allow engineers to optimize throughput, ensuring minimal latency between networks.

Features

  • Four fully independent, isolated serial ports supporting RS-232, RS-422, and RS-485 configurations.
  • Supports up to 5 EtherNet/IP Class 3 server connections and 8 Class 1 I/O connections.
  • Bi-directional data mapping between EtherNet/IP and Modbus Serial networks.
  • Configurable serial parameters including baud rate, parity, stop bits, and handshaking.
  • Diagnostics and monitoring available via web-based configuration tools.
  • Wide operating temperature range suited for unconditioned control cabinets.

Applications

  • SCADA and HMI integration with legacy Modbus field devices.
  • Power distribution networks integrating Modbus RTU power meters.
  • Oil and gas flow metering system communication.
  • Water and wastewater remote telemetry integration.
  • Industrial manufacturing assembly line automation.

Technical Specifications

ParameterSpecification
Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS4
Product Type EtherNet/IP to Modbus Serial Gateway
Number of Serial Ports 4 (isolated)
Serial Interface Types RS-232, RS-422, RS-485
EtherNet/IP Class 3 Connections 5
EtherNet/IP Class 1 I/O Connections 8
I/O Connection Size 248 / 248 bytes
Max Requested Packet Interval (RPI) 5 ms per connection
Nominal Input Voltage 24 VDC
Allowed Input Voltage Range 10 to 36 VDC
Current Load (Nominal) 300 mA @ 24 VDC
Current Load (Maximum) 610 mA @ 10 to 36 VDC
Operating Temperature -25 degC to 70 degC
Storage Temperature -40 degC to 80 degC
Shipping Weight 3 kg

Connections and Interfaces

Interface PortPhysical Connection TypeSupported Protocols
Ethernet Port RJ45 (10/100 Mbps) EtherNet/IP, TCP/IP
Serial Port 1 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 2 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 3 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 4 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Power Input 3-position terminal block Positive, Negative, GND

Installation Guidelines

  • Mounting: Install on standard 35mm DIN rails. Verify the locking mechanism is secure.
  • Grounding: Connect the dedicated ground terminal on the power connector directly to the panel functional ground using low-impedance copper wire.
  • Wiring: Route communication cabling (Ethernet and Serial) away from high-voltage AC lines to prevent electromagnetic interference.
  • Clearance: Maintain at least 50mm of clearance at the top and bottom of the module to support proper convective cooling.

Compliance and Certifications

  • CE Mark
  • UL/cUL Class I, Division 2
  • ATEX Zone 2
Loading product navigation…

What protocols does the ProSoft PLX31-EIP-MBS4 gateway bridge?

The PLX31-EIP-MBS4 bridges devices on an EtherNet/IP network with devices on Modbus Serial (RTU or ASCII) networks.

Can the serial ports be configured independently?

Yes, all four serial ports are isolated and can be individually configured for RS-232, RS-422, or RS-485 physical layer communication.

What are the power requirements for this gateway?

The module requires a nominal 24 VDC power supply, but supports an input range of 10 to 36 VDC.

How many Class 1 and Class 3 connections does it support?

It supports up to 5 Class 3 Server connections and up to 8 Class 1 I/O connections.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...