1 daripada 1

Siemens 6ES7716-2CB16-0EC4 SIMATIC Field PG M4 Programming Device

Siemens 6ES7716-2CB16-0EC4 SIMATIC Field PG M4 Programming Device

Hanya 5 item tinggal dalam stok
  • Pengilang: Siemens

  • No. Produk: 6ES7716-2CB16-0EC4

  • Negara asal:Jerman

  • Jenis Produk: Industrial Programming Device

  • Kod Bar: 84713000

  • Pembayaran: T/T, Western Union

  • Berat: 3500g

  • Dimensi: 39.50 cm x 30.00 cm x 17.00 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

The Siemens 6ES7716-2CB16-0EC4 is a SIMATIC Field PG M4 Premium Plus programming device, engineered for industrial automation tasks. This robust mobile workstation features an Intel Core i7-35X0M processor with 4 MB cache, operating at 2.9 GHz (up to 3.6 GHz with Turbo Boost technology). It is equipped with 16 GB of RAM (2x 8GB) and a 300 GB SATA Solid-State Drive (SSD) for fast performance and reliable data storage. The device includes an S5 interface with an S5-EPROMMER, an S5-AG cable, and an EPROM adapter, facilitating compatibility with older Siemens S5 systems. It also features a DVD RW optical drive and HD Graphics 4000, displayed on a 15.6-inch Full HD (1920x1080) screen. The 6ES7716-2CB16-0EC4 supports dual-boot operation with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit) and comes with pre-installed software licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5, along with an MPI cable. It features an AZERTY (French) keyboard layout and includes a power supply cable suitable for DE, FR, NL, SP, BEL, OES, SWD, FIN regions.

Features

  • Model: SIMATIC Field PG M4 Premium Plus
  • Processor: Intel Core i7-35X0M (2.9 GHz, up to 3.6 GHz with Turbo Boost, 4 MB Cache)
  • RAM: 16 GB (2x 8GB)
  • Storage: 300 GB SATA Solid-State Drive (SSD)
  • Optical Drive: DVD RW
  • Graphics: HD Graphics 4000
  • Display: 15.6-inch Full HD (1920x1080)
  • Operating System: Dual Boot (Windows XP Professional SP3 and Windows 7 Ultimate SP1, 64-bit)
  • Pre-installed Software: STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5 (Software version V13.0.1.0)
  • Interfaces: S5 interface with S5-EPROMMER, MPI
  • Keyboard: AZERTY (French) layout
  • Included Accessories: S5-AG cable, EPROM adapter, MPI cable, regional power supply cable

Applications

The Siemens SIMATIC Field PG M4 is designed for a range of industrial automation applications, including:

  • Programming, configuration, and commissioning of Siemens SIMATIC S7 and S5 PLCs.
  • On-site diagnostics and troubleshooting for automation systems.
  • Development and maintenance of HMI/SCADA projects using WinCC and WinCC flexible.
  • Data backup and restoration for industrial controllers.
  • Engineering tasks requiring a robust, portable computing platform in industrial environments.

Technical Specifications

Parameter Value
Manufacturer Siemens
Range SIMATIC Field PG
Subrange Field PG M4
Product Type Premium Plus Programming Device
PLM Product Phase Phase-Out
Processor Intel Core i7-35X0M
Processor Speed 2.9 GHz (up to 3.6 GHz with Turbo Boost)
Processor Cache 4 MB
RAM 16 GB (2x 8GB)
Storage Type SATA Solid-State Drive (SSD)
Storage Capacity 300 GB
Optical Drive DVD RW
Graphics HD Graphics 4000
Display Size 15.6 inches
Display Resolution Full HD (1920x1080)
Keyboard Layout AZERTY (French)
Operating System 1 Windows XP Professional SP3
Operating System 2 Windows 7 Ultimate SP1 (64-bit)
Pre-installed Software STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, STEP 5
Software Version V13.0.1.0
Included Cables S5-AG cable, MPI cable, Regional Power Supply Cable (DE, FR, NL, SP, BEL, OES, SWD, FIN)
Included Adapters EPROM adapter
Package Dimensions (Calculated) 39.50 cm x 30.00 cm x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N
Country of Origin Germany

Connections / Interfaces

  • S5 Interface with S5-EPROMMER
  • MPI (Multi-Point Interface)
  • DVD RW Optical Drive

Installation Guidelines

  1. Unpacking and Inspection: Carefully unpack the Field PG M4 and inspect for any visible shipping damage. Retain original packaging for potential future transport.
  2. Power Connection: Connect the provided regional power supply cable to the Field PG M4 and a suitable mains outlet. Ensure the power source meets the device's electrical requirements.
  3. Initial Boot-up: Power on the device. The dual-boot system allows selection between Windows XP Professional SP3 and Windows 7 Ultimate SP1. Select the appropriate operating system for your programming tasks.
  4. Software Verification: Confirm that all pre-installed software, including STEP7 Professional, WinCC Advanced, STEP 7 Micro/WIN, and STEP 5, are correctly installed and licensed.
  5. Peripheral Connections: Connect necessary programming cables, such as the S5-AG cable or MPI cable, to the respective interfaces on the Field PG M4 and the target PLC.
  6. Environmental Considerations: Operate the Field PG M4 within a clean, dry environment, avoiding excessive dust, moisture, and extreme temperatures to ensure optimal performance and longevity.
  7. Data Backup: Regularly back up critical project data and system configurations to external storage devices to prevent data loss.
  8. Security: Implement appropriate security measures, including strong passwords and antivirus software, to protect the programming device and sensitive project data.

What operating systems are pre-installed on the SIMATIC Field PG M4?

The device features a dual-boot configuration with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit).

Which Siemens programming software is included?

It includes licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0, and STEP 5.

Does this Field PG M4 support older Siemens S5 PLCs?

Yes, it includes an S5 interface with an S5-EPROMMER, an S5-AG cable, and an EPROM adapter for S5 compatibility.

What is the display size and resolution?

The SIMATIC Field PG M4 features a 15.6-inch display with Full HD (1920x1080) resolution.

What type of storage is used in this device?

It is equipped with a 300 GB SATA Solid-State Drive (SSD).

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...