1 daripada 1

Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier

Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier

Hanya 10 item tinggal dalam stok
  • Pengilang: Weidmuller

  • No. Produk: 8965350000

  • Negara asal:Jerman

  • Jenis Produk: Isolating Switch Amplifiers

  • Pembayaran: T/T, Western Union

  • Berat: 175g

  • Dimensi: 117.2 mm x 22.5 mm x 113.6 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Weidmuller 8965350000 ACT20X-HDI-SDO-RNC-S ACT20X Isolating Switch Amplifier

Description

Designed for intrinsically safe signal processing, the Weidmuller 8965350000 functions as a high-reliability isolating switch amplifier within the ACT20X series. This module is engineered to safely isolate and transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe-area control environments. It supports inputs from NAMUR sensors or mechanical switch contacts and converts them into relay outputs.

The ACT20X-HDI-SDO-RNC-S features comprehensive galvanic isolation between the input, output, and power supply circuits, ensuring superior signal integrity and system protection. Configuration is managed via standard FDT/DTM software, allowing operators to easily set parameters, monitor device status, and configure line fault detection (LFD) for open-circuit or short-circuit conditions.

Features

  • Intrinsically safe digital inputs compatible with NAMUR sensors and mechanical switches.
  • Relay output configuration for reliable safe-area signal switching.
  • Galvanic isolation across input, output, and power supply channels.
  • Software-based configuration utilizing standard FDT/DTM tools.
  • Integrated line fault detection (LFD) to identify open and short circuits in the field wiring.
  • Compact 22.5 mm housing designed for standard DIN-rail mounting.

Applications

  • Oil and gas processing and refining facilities.
  • Chemical and petrochemical manufacturing plants.
  • Water and wastewater treatment systems.
  • Power generation and distribution utilities.
  • Hazardous area signal isolation and safety instrumented systems (SIS).

Technical Specifications

ManufacturerPart Number/ModelProduct SeriesInput TypeSensor SupplyOutput TypeNominal Switching VoltageSupply VoltagePower ConsumptionConfiguration InterfaceConnection TypeIP RatingOperating TemperatureStorage TemperatureHumidityDimensions (H x W x D)Weight
Weidmuller
8965350000 (ACT20X-HDI-SDO-RNC-S)
ACT20X
NAMUR sensor (DIN EN 60947-5-6), switch contact
8 V DC / 8 mA
Relay
<= 125 V AC / 110 V DC (safe area), <= 32 V AC / 32 V DC (Zone 2)
19.2 to 31.2 V DC
<= 1.3 W
FDT/DTM software
Screw connection
IP20
-20 to +60 Celsius
-20 to +85 Celsius
0 to 95% (non-condensing)
117.2 mm x 22.5 mm x 113.6 mm
175 g

Installation Guidelines

  • Mounting: Snap securely onto a standard TS 35 DIN rail in a vertical orientation to optimize heat dissipation.
  • Wiring Separation: Maintain a minimum physical distance of 50 mm between intrinsically safe (Ex i) field wiring and non-intrinsically safe wiring.
  • Grounding: Ensure the DIN rail is properly bonded to the functional earth ground of the control cabinet.
  • Cabinet Protection: For installation in Zone 2 environments, the module must be mounted inside an enclosure providing a minimum protection rating of IP54.

Compliance and Certifications

  • ATEX
  • IECEx
  • CE
  • UL
Loading product navigation…

What is the primary function of the Weidmuller 8965350000?

The Weidmuller 8965350000 (ACT20X-HDI-SDO-RNC-S) is an intrinsically safe isolating switch amplifier designed to safely transmit digital signals from hazardous areas (such as NAMUR sensors or mechanical switches) to safe-area control systems via relay outputs.

How is the ACT20X-HDI-SDO-RNC-S configured?

This module is configured using standard FDT/DTM software, allowing operators to parameterize input types, configure line fault detection, and monitor device diagnostics.

What are the power supply requirements for this module?

The module requires a nominal supply voltage of 19.2 V DC to 31.2 V DC and has a maximum power consumption of 1.3 W.

Does the module support line fault detection?

Yes, the ACT20X-HDI-SDO-RNC-S features integrated line fault detection (LFD) to monitor the field wiring for open-circuit and short-circuit conditions.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...