1 daripada 1

Weidmuller 8965360000 ACT20X-HDI-SDO-S Isolating Switch Amplifier

Weidmuller 8965360000 ACT20X-HDI-SDO-S Isolating Switch Amplifier

Hanya 10 item tinggal dalam stok
  • Pengilang: Weidmuller

  • No. Produk: 8965360000

  • Negara asal:Jerman

  • Jenis Produk: Isolating Switch Amplifiers

  • Pembayaran: T/T, Western Union

  • Berat: 1200g

  • Dimensi: 117.2 mm x 22.5 mm x 113.6 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Processing digital signals from hazardous areas requires robust galvanic isolation, which the Weidmuller 8965360000 ACT20X-HDI-SDO-S delivers as a high-performance, 2-channel isolating switch amplifier. This device safely transmits switching states from NAMUR sensors or mechanical contacts located in Zone 0, 1, or 2 hazardous areas to the safe area control system, providing complete electrical separation and signal conditioning in a compact form factor.

Key Features

  • Dual-channel intrinsically safe input for NAMUR sensors or dry mechanical contacts.
  • Galvanic 4-way isolation between input, output, power supply, and status output.
  • Integrated line fault detection (LFD) for continuous wire-break and short-circuit monitoring.
  • FDT/DTM software-configurable parameters for custom application tuning and diagnostics.
  • Relay outputs (1 changeover contact per channel) for robust load switching.
  • Compact 22.5 mm DIN-rail housing to optimize cabinet space.

Applications

  • Intrinsically safe signal isolation in chemical and petrochemical processing plants.
  • Oil and gas pipeline monitoring systems requiring Zone 0/1 sensor deployment.
  • Water and wastewater treatment facility telemetry and pump control.
  • Hazardous area valve position feedback and limit switch integration.

Technical Specifications

Parameter Value
Manufacturer Weidmuller
Article Number 8965360000
Model ACT20X-HDI-SDO-S
Number of Channels 2
Input Type NAMUR sensor (DIN EN 60947-5-6) or mechanical switch
Output Type Relay (1 changeover contact per channel)
Nominal Switching Voltage 250 V AC / 30 V DC
Supply Voltage 19.2 to 31.2 V DC
Power Consumption <= 1.1 W
Isolation Voltage 2.6 kV AC (input / output / power)
Connection Technology Screw connection
Clamping Range 0.5 to 2.5 mm2
Flammability Rating UL 94 V-0
Protection Degree IP20
Operating Temperature -20 to +60 degC
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Net Weight 0.170 kg

Connections and Interfaces

Terminal Pin Function / Circuit Assignment
11 / 12 Channel 1 Input (NAMUR Sensor / Mechanical Switch)
21 / 22 Channel 2 Input (NAMUR Sensor / Mechanical Switch)
51 / 52 / 53 Channel 1 Relay Output (NC / COM / NO)
61 / 62 / 63 Channel 2 Relay Output (NC / COM / NO)
91 / 92 Power Supply (19.2 to 31.2 V DC: + / -)

Alternative Models & Compatibility

The ACT20X-HDI-SDO-S is part of Weidmuller's premium ACT20X signal converter family. It serves as a direct replacement or upgrade path for legacy ACT20 series modules. When migrating from older systems, verify that your configuration files are updated in the FDT/DTM frame to match the specific firmware revision of the 8965360000 module.

Application Pitfalls & Engineering Notes

When utilizing standard mechanical switches instead of NAMUR sensors, the Line Fault Detection (LFD) circuit must be configured correctly. If LFD is enabled without external resistors, the module will interpret an open switch as a wire break and a closed switch as a short circuit. To prevent false diagnostics, either disable LFD via the DTM software or wire a resistor network (typically 1k Ohm in series and 10k Ohm in parallel) directly at the switch contacts.

Commissioning & Wiring Tips

Configuration is performed using the Weidmuller WI-Manager software via the front-panel service jack. Ensure the CBX200 USB interface cable is used for connection. For field wiring, maintain a minimum physical separation of 50 mm between the intrinsically safe (Ex i) blue terminals on the left side and the non-intrinsically safe terminals on the right side to comply with international hazardous area installation standards.

Installation Guidelines

CRITICAL WARNING

De-energize all power sources before mounting, wiring, or configuring the device. Failure to isolate power can result in electrical shock or spark generation in hazardous areas, compromising explosion protection safety.

1
Snap the module vertically onto a standard TS 35 DIN rail, ensuring the metal grounding spring on the back makes secure contact with the rail.
2
Connect the intrinsically safe field sensors to the blue terminals (11/12 and 21/22), ensuring proper cable routing away from power lines.
3
Wire the relay outputs and the 24 V DC power supply to the black terminals on the opposite side of the module.
4
Connect the configuration interface to set the desired input/output logic and LFD parameters using the FDT/DTM software before commissioning.
Loading product navigation…

How do I configure the Line Fault Detection (LFD) for a standard mechanical switch?

To use LFD with a mechanical switch, you must wire an external resistor network at the switch contacts: a 1k Ohm resistor in series and a 10k Ohm resistor in parallel. Alternatively, you can disable LFD entirely using the Weidmuller FDT/DTM software.

What software is required to configure the ACT20X-HDI-SDO-S?

Configuration requires the Weidmuller WI-Manager software (FDT frame) along with the device-specific ACT20X DTM package and a CBX200 USB interface cable.

Can this isolating amplifier be installed directly in Zone 0?

No, the module itself must be installed in a safe area or Zone 2 (inside a suitable protective enclosure). However, its input circuits are certified intrinsically safe for direct connection to devices located in Zone 0, 1, or 2.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...