1 daripada 1

Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Weidmuller 8965420000 ACT20X-2SDI-2HDO-S Valve Control Module

Hanya 10 item tinggal dalam stok
  • Pengilang: Weidmuller

  • No. Produk: 8965420000

  • Negara asal:Jerman

  • Jenis Produk: Intrinsically Safe Valve Drivers

  • Pembayaran: T/T, Western Union

  • Berat: 1200g

  • Dimensi: 117.2 mm x 22.5 mm x 113.6 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Facilitating the safe control of intrinsically safe valves in hazardous environments, the Weidmuller 8965420000 (ACT20X-2SDI-2HDO-S) provides reliable signal isolation and switching. This dual-channel valve control module acts as an isolated barrier, translating control signals from the safe area into intrinsically safe outputs to drive solenoids, valves, and acoustic alarms located in Ex zones.

Key Features

  • Dual-Channel Isolation: Supports two independent channels for space-saving, high-density cabinet layouts.
  • Integrated Diagnostics: Built-in alarm function detects and reports supply voltage loss and internal device errors.
  • Software Configurable: Fully compatible with FDT/DTM software for precise parameter adjustment and monitoring.
  • Secure Connections: Equipped with robust screw terminals to ensure vibration-resistant field wiring.
  • Compact Profile: 22.5 mm housing width optimizes DIN-rail space in control enclosures.

Industrial Applications

  • Oil & Gas Refineries: Actuation of intrinsically safe solenoid valves in hazardous processing zones.
  • Chemical Processing: Safe signal transmission and isolation for chemical dosing and distribution systems.
  • Pharmaceutical Manufacturing: Control of pneumatic and hydraulic valves in explosive dust or gas atmospheres.
  • Water & Wastewater Treatment: Isolated valve control in wet wells and chemical treatment areas.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Weidmuller
Article Number (SKU) 8965420000
Model Designation ACT20X-2SDI-2HDO-S
Product Type Intrinsically Safe Valve Control / Solenoid Driver
Number of Channels 2
Supply Voltage Range 19.2 to 31.2 V DC
Power Consumption <= 3.1 W
Nominal Switching Voltage <= 125 V AC / 110 V DC
Continuous Current <= 0.5 A AC / 0.3 A DC
Step Response Time 10 ms
Configuration Method FDT/DTM software
Connection Type Screw connection
Operating Humidity 0 to 95% (non-condensing)
Protection Degree IP20
Net Weight 0.180 kg
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Shipping Weight (Calculated) 1.2 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The ACT20X-2SDI-2HDO-S is highly compatible with standard DCS and PLC digital output cards. When integrating this module into existing systems configured with older ACT20 series units, ensure that the FDT/DTM frame application is updated to the latest device description files to prevent communication errors during setup.

Application Pitfalls & Engineering Notes

When mounting multiple units side-by-side on a DIN rail, ensure the cabinet's thermal management system is active. Under maximum continuous current loads (0.5 A AC / 0.3 A DC), heat dissipation within high-density enclosures can rise. Maintain a minimum clearance or use active ventilation if the ambient temperature inside the panel consistently exceeds 45 degC.

Commissioning & Wiring Tips

Always maintain strict physical separation between the blue intrinsically safe (Ex-i) field wiring and the non-intrinsically safe supply/alarm connections. Mixing these routing paths violates hazardous area compliance. Use shielded cabling for the control signals to minimize high-frequency noise interference in high-transient environments.

Installation Guidelines

CRITICAL WARNING

Isolate and de-energize all power sources before mounting, wiring, or configuring this module. Ensure the surrounding atmosphere is verified as non-hazardous (gas-free) before opening any protective enclosures or adjusting field connections.

1

Snap the module securely onto a standard TS 35 DIN rail, ensuring the grounding spring makes solid contact with the rail.

2

Connect the 19.2 to 31.2 V DC power supply to the designated non-Ex power terminals.

3

Wire the intrinsically safe valve/solenoid field devices to the blue Ex-i screw terminals, keeping the cables physically isolated from power lines.

4

Connect the alarm relay outputs to your supervisory PLC or safety system to monitor for voltage loss or device faults.

Loading product navigation…

What software is required to configure the ACT20X-2SDI-2HDO-S?

The module is configured using standard FDT/DTM software, which allows for precise parameter adjustments, diagnostic monitoring, and channel setup.

Can this module be used in explosive atmospheres?

Yes, the module is designed as an intrinsically safe (Ex-i) barrier, allowing it to safely interface with solenoids and valves located in hazardous areas.

What diagnostic functions are integrated into the 8965420000?

It features an integrated alarm function that triggers a relay output in the event of a supply voltage loss or an internal device error.

What is the step response time of this valve control module?

The module features a fast step response time of less than or equal to 10 milliseconds, ensuring rapid valve actuation.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...