Yokogawa ADV142-P13 S1 CENTUM VP AC Digital Input Module

Yokogawa ADV142-P13 S1 CENTUM VP AC Digital Input Module

Only 10 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: ADV142-P13 S1

  • Country of origin:Jepun

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 3.2cm x 10.7cm x 13cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The ADV142-P13 S1 (ADV142) is a robust 16-channel isolated digital input module designed for the Yokogawa CENTUM VP distributed control system (DCS). Specifically engineered to interface with high-voltage 200 V to 240 V AC signals, this module is essential for monitoring the status of heavy-duty industrial equipment such as motor starters, switchgear, and large-scale actuators. The ADV142 features integrated pushbutton input logic, allowing for the precise counting of signal edges in operator-interface applications. This unit is built for extreme reliability, featuring ISA Standard G3 conformal coating to resist corrosive gases and an extended operating temperature range of -20 to 70 deg C. By supporting dual-redundant configurations and providing high-level galvanic isolation, the module ensures continuous process monitoring and significantly reduces the risk of unplanned downtime in harsh environments like oil refineries, power plants, and chemical processing facilities.

Suffix Breakdown

The suffix codes for the ADV142-P13 define its specialized hardware hardening and functional capabilities:

  • -P: Equipped with the Pushbutton Input function, allowing the module to detect and count the edges of pushbutton signals with a dedicated minimum detection time.

  • 1: Categorized as a General-purpose type, optimized for standard high-voltage AC sensing within the FIO subsystem.

  • 3: Includes the ISA Standard G3 corrosion resistance option and the extended ambient temperature option (-20 to 70 deg C).

  • S1: Designates the Style 1 hardware revision, ensuring compatibility with current CENTUM VP node units and field network I/O.

Technical Specifications

Feature Specification
Model ADV142-P13 S1
Brand Yokogawa
Origin Japan
Input Channels 16, isolated (8 channels per common)
Rated Input Voltage 200 to 240 V AC (50/60 Hz)
Input ON Voltage 160 V AC (226 V Peak) to 264 V AC
Input OFF Voltage 40 V AC (56 V Peak) or less
Withstanding Voltage 2 kV AC (Input to System) / 1.35 kV AC (Between Commons)
Operating Temp -20 to 70 deg C
Environmental Rating ISA Standard G3 (Conformal Coating)
Weight Approx. 0.30 kg

Technical FAQs

How does the G3 option benefit the module's lifespan?

The G3 option applies a specialized conformal coating that protects internal circuitry from atmospheric corrosion caused by gases like Hydrogen Sulfide (H2S), Chlorine (Cl2), and Nitrogen Dioxide (NO2), which are common in paper mills and wastewater treatment plants.

What is the critical phase requirement for wiring this module?

All AC input signals connected to the same common minus (-) side (grouped every 8 channels) must be on the same electrical phase. Connecting multiple phases to a single common can cause catastrophic hardware failure.

Can this module handle high-frequency pulse signals?

No. While the ADV142 has a pushbutton counting function, it is limited to a maximum cycle of 2.5 Hz. For high-speed pulse counting (up to 10 kHz), a dedicated pulse input module like the AAP135 is required.


Engineering & Installation Guide

  • High-Voltage Safety: The ADV142 processes potentials up to 264 V AC. Ensure all field power is isolated before wiring the pressure clamp terminals. Use 1.25 mm2 or smaller cross-sectional area wire and verify that the terminal covers are securely installed to prevent accidental contact.

  • Thermal Considerations: When operating at the upper limit of the temperature range (up to 70 deg C), ensure the control cabinet has active ventilation. Avoid placing high-heat generating modules (like power supplies) directly beneath the ADV142 to prevent localized overheating.

  • Signal Integrity: To minimize electromagnetic interference (EMI), route the high-voltage AC input cables away from low-voltage DC signal lines. Use shielded cables if the wiring run exceeds 50 meters, and ground the shield at the cabinet end only.

  • Cable Selection: For reliable high-density connections, the use of the Yokogawa AKB333 dedicated cable is recommended. This cable is specifically designed to meet the insulation requirements for 220 V AC signals across 16 channels.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Yokogawa ADV142-P13 S1 CENTUM VP AC Digital Input Module

正在加载 PDF,请稍候…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu
Country of origin
Jepun
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...