1 z 1

BECKHOFF ER2349-0021 EtherCAT Box 16-Channel Digital I/O Module

BECKHOFF ER2349-0021 EtherCAT Box 16-Channel Digital I/O Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ER2349-0021

  • Country of origin:Niemcy

  • Product Type: EtherCAT I/O Modules

  • Payment: T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Decentralized field installation without a control cabinet is streamlined with the ER2349-0021 EtherCAT Box. This robust, IP67-rated module handles up to 16 digital signals, each of which is independently configurable as either an input or an output. Operating on the high-performance EtherCAT protocol, it interfaces directly with field sensors and actuators via compact M8 screw-type connection sockets. Its versatile design is optimized for space-constrained industrial setups requiring reliable, high-density I/O routing directly in harsh environments.

Features

  • 16 digital channels, freely configurable as inputs or outputs to match dynamic field requirements.
  • EtherCAT high-speed fieldbus communication with integrated M8 shielded, screw-type interfaces.
  • Robust housing with IP65, IP66, and IP67 protection ratings conforming to EN 60529, suitable for wet, dusty, or wet-cleaning environments.
  • Individual short-circuit protection on each channel to safeguard connected sensors and actuators.
  • Integrated 500 V electrical isolation between the fieldbus logic and load supply.

Applications

  • Automotive manufacturing assembly lines and robotic work cells.
  • Packaging, sorting, and material handling systems requiring decentralized, on-machine IP67 modules.
  • Special-purpose machine building and heavy-duty process automation configurations.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ER2349-0021
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw type
Specification Standards EN 61131-2, type 1/3
Number of Channels 16 digital inputs or outputs, configurable
Input/Output Connections M8 x 1, 3-pin, a-coded
Input Filter Time 10 us
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V, 6 mA input current (EN 61131-2, type 3)
Sensor Supply From load supply voltage, max. 0.5 A, short-circuit proof in total
Load Type Ohmic, inductive, lamp load
Rated Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel, individually short-circuit proof, sum 4 A
Switching Times Typical TON: 60 us, typical TOFF: 300 us
Short-Circuit Current Typical 1.5 A
Auxiliary Power Current Typical 20 mA + load
Current Consumption from US 130 mA
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream connection: 1 x M8 female socket, 4-pin
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration and Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 450 g

Connections and Interfaces

Connection Interface Specification / Type
EtherCAT Bus 2 x M8 socket, shielded, screw-type connection
Digital Inputs/Outputs 16 x M8 x 1, 3-pin, a-coded
Power Feed 1 x M8 male socket, 4-pin
Downstream Power 1 x M8 female socket, 4-pin

Installation Guidelines

Ensure the ER2349-0021 EtherCAT Box is securely mounted to a flat surface using the integrated screw mounting holes. Tighten all M8 connection cables to their specified torque ratings to preserve the unit's IP65/66/67 physical protection barrier. Route control network cabling and high-power electrical drive lines in separate paths to minimize electromagnetic interference. Ground the bus system via the integrated earthing connection point.

Compliance and Certifications

  • CE
  • UL

Are the digital channels on the ER2349-0021 inputs or outputs?

The 16 digital channels on the ER2349-0021 are freely configurable, allowing each individual channel to be configured as either a digital input or a digital output.

What is the physical protection rating of the ER2349-0021?

It features an IP65/66/67 rating conforming to EN 60529, making it highly resistant to dust, water jets, and temporary immersion, suitable for direct machine mounting without a control cabinet.

What physical connector types does the module use for communication and power?

The EtherCAT bus utilizes 2 x M8 shielded screw-type sockets, the digital I/O uses M8 3-pin a-coded connections, and the power feed/downstream interfaces use 4-pin M8 sockets.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...