Bently Nevada 133292-01 Low Voltage DC Power Supply Module

Bently Nevada 133292-01 Low Voltage DC Power Supply Module

Only 6 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 133292-01

  • Country of origin:Stany Zjednoczone

  • Product Type: Power Supply Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1390g

  • Dimensions: 120.7 mm x 50.8 mm x 251.5 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The 133292-01 is a half-height hardware module designed to supply stable and regulated power within the 3500 Series Machinery Protection System. It functions as a legacy low-voltage power regulation unit, converting low-voltage direct current input source feeds into predefined voltage profiles mandatory for running adjacent condition monitoring and rack processing modules. Positioned specifically within dedicated slots on the far left side of a standardized rack chassis, this hardware option can work as a standalone power source or operate in parallel configuration with a secondary matching card to deliver uninterrupted system redundancy. The card accepts specialized low-voltage DC inputs via a corresponding rear-mounted Power Input Module (PIM), making it an essential replacement spare across automated manufacturing frameworks, petrochemical facilities, and heavy turbomachinery installations requiring high-availability monitoring infrastructure.

Features

  • Half-height physical design footprint to fit designated left-side power slots of the chassis framework.
  • Integrates dual-supply redundancy mode with automatic primary/backup switching logic when installed with a secondary module.
  • Hot-swappable installation architecture enabling direct replacement of a damaged block without disturbing active machinery protection loops.
  • Built-in front-facing diagnostics with a dedicated LED utility status light indicating proper module regulation performance.
  • Comprehensive under-voltage safety measures engineered to safeguard interior multi-layer circuit boards from electrical faults.
  • High compatibility with legacy low-voltage DC backplane distributions for efficient hardware migration.

Applications

  • Powering machinery protection racks on remote oil and gas transport pipelines driven by low-voltage DC batteries.
  • Power distribution management for localized rotating asset vibration arrays inside petrochemical processing units.
  • Power provisioning for critical turbine and generator tracking networks utilizing standalone solar or battery bank utilities.

Ordering Information

Option Code Description
3500/15-AA-BB-CC Complete Power Supply assembly ordering structure.
A: 04 Legacy Low Voltage DC (20 to 30 Vdc) option for Top Slot.
B: 04 Legacy Low Voltage DC (20 to 30 Vdc) option for Bottom Slot.
C: 00 Agency Approval Option: None.
C: 01 Agency Approval Option: CSA/NRTL/C (Class 1, Division 2).
C: 02 Agency Approval Option: ATEX / IECEX / CSA (Class 1, Zone 2).
133292-01

 

Spare Parts: Legacy Low Voltage DC Power Supply Module.

133300-01

 

Spare Parts: Legacy Low Voltage DC Power Input Module.

01720045

 

Spare Parts: Replacement Fuse (Low Voltage DC Power Input Module and Legacy Low Voltage DC Power Input Module).

Technical Specifications

Parameter Category Specification Details
Manufacturer Bently Nevada (Baker Hughes)
Product Model 3500/15
Spare Part Number

 

133292-01

Input Voltage Range 20 to 30 Vdc
Full Rack Current Draw 11.0 A maximum
Under-Voltage Fault Supply protected, no damage occurs to module or PIM
Over-Voltage Protection Triggers open status on the designated PIM primary fuse
Minimum Loading No minimum rack load is required
Operating Temperature -30 degC to +65 degC (-22 degF to +150 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 95%, non-condensing
Supply Module Width 50.8 mm (2.0 in)
Supply Module Height 120.7 mm (4.75 in)
Supply Module Depth 251.5 mm (9.9 in)
Supply Module Weight 1.39 kg (3.06 lb)

Connections/Interfaces

The interface layout manages power supply statuses and connection tracking on the chassis system:

Component Identifier Functional Description / Assignment
SUPPLY OK LED Front panel status light; glows steadily green when internal rails generate appropriate voltage outputs.
Top Card Slot Designated slot container on the left side of the framework acting as the secondary/backup bay.
Bottom Card Slot Designated slot container on the left side of the framework acting as the primary system power position.
Rear PIM Board Mount Specialized receiver point located directly behind the card to capture incoming low-voltage DC lines.

Installation Guidelines

  • Slot Allocation: Mount the unit exclusively inside the designated half-height slot windows located on the left side of the main rack assembly.
  • Redundancy Priority: Populate the lower half-height bay to assign the hardware module as the primary supply source, or utilize the upper bay position for backup purposes.
  • PIM Matching: Always pair the 133292-01 supply module with its correct corresponding legacy low-voltage DC backplane PIM (part number 133300-01) to avoid electrical mismatches.
  • Hot-Swap Execution: Ensure that a separate active power supply card remains online within the opposite power bay before removing or executing a live swap of this item.
  • Fuse Maintenance: If an over-voltage condition happens, check and swap the dedicated protection fuse (part number 01720045) on the associated backplane interface module.

Compliance and Certifications

  • EMC Directives: European Community Directive 2014/30/EU.
  • EMC Standards: EN 61000-6-2 (Industrial Immunity), EN 61000-6-4 (Industrial Emissions).
  • Electrical Safety: Low Voltage Directive 2014/35/EU, EN 61010-1 Standard.
  • RoHS Directive: 2011/65/EU European Compliance.
  • Maritime Approvals: DNV GL rules for classification, ABS Steel Vessels Rules.
  • North American Approvals: cNRTLus Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC).
  • ATEX/IECEx Approvals: II 3 G Ex nA nC ic IIC T4 Gc / Ex ec nC ic IIC T4 Gc.

FAQ

What is the functional difference between 133292-01 and the updated high-efficiency DC power modules?

The 133292-01 is a legacy-type low-voltage DC module designed specifically for older styles of 3500 power distributions and it is explicitly incompatible with standard newer low-voltage DC Power Input Modules.

Does this hardware module require a minimal electrical load to maintain safe voltage output levels?

No, the processing topology of the card means no minimum rack load is required for proper circuit regulation.

Will a temporary low-voltage sag on the incoming 24V bus destroy the internal components?

No, an under-voltage input variance does not cause operational harm or permanent degradation to the internal component hardware or the coupled PIM.

Can I operate an AC power supply and a 133292-01 low-voltage DC module together inside the same rack?

Yes, the monitor chassis supports hosting any combination of alternating current and direct current power modules in the dual slots to form a highly versatile redundant configuration.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 133292-01 Low Voltage DC Power Supply Module

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Niebieski Srebro
Country of origin
Stany Zjednoczone
Power source
Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...