1 z 1

DELTA VFD037M21A VFD-M Series Sensorless Vector Micro Drive

DELTA VFD037M21A VFD-M Series Sensorless Vector Micro Drive

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD037M21A

  • Country of origin:Stany Zjednoczone

  • Product Type: Sensorless Vector Micro Drive

  • Payment: T/T, Western Union

  • Weight: 3200g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The VFD037M21A (VFD037M21A) is a highly compact, sensorless vector micro drive from Delta's VFD-M series, engineered for applications where space is at a premium. Rated for 2.2 kW (3.0 HP) continuous industrial operation, this drive provides high-frequency stability and exceptional torque performance. It is an ideal solution for automated conveyor lines, food processing equipment, woodworking machinery, and ventilation fans. By integrating dynamic torque compensation and built-in PID control loops, the VFD037M21A safeguards system continuity and minimizes unscheduled downtime. Its flexible power stage allows for efficient integration into facilities using either single-phase or three-phase 200–240 V power.

Technical Configuration

This micro drive is designed for maximum adaptability, featuring a bridge rectifier that natively supports both single-phase and three-phase incoming power sequences. It implements Sensorless Vector Control (SVC) alongside standard V/f curves, delivering automatic torque boosting at low speeds to handle high-friction starting loads. The drive supports an adjustable carrier frequency (1–15 kHz), allowing engineers to tune the balance between motor noise suppression and internal thermal dissipation. Furthermore, the unit includes an overvoltage stall prevention algorithm, which automatically adjusts deceleration timing to protect the DC bus during rapid load shedding or braking.

Technical Specifications

Feature Specification
Model VFD037M21A
Brand DELTA
Power Rating 2.2 kW (3.0 HP)
Output Current 10 A (Continuous)
Input Voltage 1-phase or 3-phase 200–240 VAC
Output Frequency 0.1–400 Hz
Cooling Method Forced-air fan
Control Mode Sensorless Vector (SVC), V/f
Carrier Frequency 1–15 kHz (Adjustable)
Weight 3.20 kg

FAQs

What are the performance differences between single-phase and three-phase input?

The drive delivers its full 10 A output in either configuration. When supplied with single-phase power, the input terminals draw 11.5 A. When supplied with 3-phase power, the input current drops to 7.6 A due to balanced phase loading, which reduces thermal stress on the internal rectifiers.

Does this drive require external braking components?

The drive includes overvoltage stall prevention to manage energy regenerated during deceleration. However, for rapid braking cycles involving high-inertia loads, an external dynamic braking resistor should be connected to the terminals.

Can this drive be used in dusty or damp environments?

The standard chassis is not sealed against moisture or dust. It is certified for dry, clean environments. For use in facilities with high humidity, chemicals, or fine dust (like woodworking shops), it must be mounted inside a sealed IP54 or NEMA 12 rated industrial enclosure.

How is the drive protected against electrical noise?

The drive should be installed with all power and control lines physically separated by at least 100 mm to prevent electromagnetic noise injection. Additionally, a direct star-ground layout is required to safely redirect common-mode currents.

Field Commissioning & Safety Guidelines

  • Thermal Clearances: Mount the drive vertically onto a flat, non-combustible metallic sub-panel. Maintain at least 50 mm of clearance on both sides and 120 mm above and below the chassis to ensure unhindered airflow from the forced-air cooling fan.

  • Cabling Separation: Route incoming power lines (L1, L2/N) and motor leads (U, V, W) inside distinct conduits separated from low-voltage digital inputs, 4-20mA speed commands, and communication wires by at least 100 mm.

  • Grounding Protocol: Connect the primary ground terminal directly to the central panel earth bus using a heavy-gauge, low-impedance conductor. Avoid daisy-chaining ground connections; a direct star-ground layout is required to mitigate common-mode currents generated by IGBT switching.

 

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Biały
Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...