1 z 6

E82ZAFAC Lenze 8200-series Standard I/O Analog Application Module

E82ZAFAC Lenze 8200-series Standard I/O Analog Application Module

Only 6 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: E82ZAFAC

  • Country of origin:Niemcy

  • Product Type: Analog Modules

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 120g

  • Dimensions: 5cm x 1cm x 7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The E82ZAFAC (E82ZAFAC) is a versatile I/O application module designed for the Lenze 8200 Vector and 8200 Motec series of frequency inverters. This module acts as a bridge between the inverter's internal processing and external control hardware, providing a comprehensive array of digital and analog connection points. In industrial B2B applications—such as synchronized multi-drive conveyors, dosing systems, and climate control automation—the E82ZAFAC is a critical component for integrating local sensors, potentiometers, and PLC signals. By utilizing this module, system engineers can achieve precise closed-loop speed control and complex logic sequences directly at the drive level. Although currently in its phase-out stage, the E82ZAFAC remains an essential resource for maintaining the flexibility and connectivity of existing 8200-series installations, offering German-engineered reliability in a compact, modular format.

Technical Configuration

The E82ZAFAC is architected for "hot-plug" integration into the standard AIF (Automation Interface) slot located on the front of the 8200-series drives. The module features a high-density terminal configuration, including 7 digital inputs for sequence control (e.g., start/stop, clockwise/counter-clockwise, fixed speeds) and 2 digital outputs for status signaling (e.g., "Ready" or "Fault" states). The analog section is equally robust, providing 2 analog inputs (0-10V or 0/4-20mA) for setpoint values or sensor feedback, and 2 analog outputs for visualizing actual values like motor frequency or current on external meters. Its ultra-compact 5 x 1 x 7 cm footprint and lightweight 0.12 kg build allow for maximum functionality without increasing the overall dimensions of the inverter unit.

Technical Specifications

Attribute Specification Details
Model E82ZAFAC
Brand Lenze
Origin Germany
Product Range 8200-series (Vector / Motec)
Module Type Standard I/O / Analog Module
Digital Inputs 7 Configurable Inputs
Digital Outputs 2 Configurable Outputs
Analog Inputs 2 (0-10V, 0/4-20mA)
Analog Outputs 2 (0-10V)
Weight 0.12 kg
Product Status Phase-Out
Commodity Code 85371091

Technical FAQs

How do I switch the analog inputs between voltage (0-10V) and current (4-20mA) signals?

The signal type for the analog inputs on the E82ZAFAC is typically determined by internal parameter settings within the 8200-series inverter (such as parameter C0034). Some hardware versions may also require the adjustment of miniature internal DIP switches or jumpers located on the module itself prior to installation.

Is the E82ZAFAC compatible with the newer i550 series?

No. The E82ZAFAC is specifically designed for the AIF slot architecture of the 8200-series. Newer Lenze drives like the i550 utilize a different modular interface system. To transition to newer technology, a complete drive and I/O module upgrade is required.

Can I use the digital inputs for high-speed counting?

While the digital inputs are optimized for standard control logic and switching, their sample rate is limited by the inverter's internal processing cycle. For high-speed pulse counting or positioning, specialized function modules or the 9300-series are generally recommended.


Engineering & Installation Guide

For successful installation of the E82ZAFAC, ensure the inverter is powered down before inserting the module into the AIF slot to prevent electrical transients. When wiring the analog inputs, use shielded twisted-pair cables to protect the low-voltage signals from electromagnetic interference generated by the motor cables. The shield should be grounded at the inverter's shield plate. To prevent signal noise, maintain a separation of at least 10 cm between the I/O wiring and the high-voltage power cables. Once installed, use the Lenze Global Drive Control (GDC) software or a plug-in keypad to assign the desired functions to the I/O terminals (e.g., assigning a specific digital input to "DC Braking" or an analog output to "Motor Torque").

 

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Biały
Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...