1 z 6

EVF9324-EV Lenze 9300-Series Vector Frequency Inverter 3.0 kW

EVF9324-EV Lenze 9300-Series Vector Frequency Inverter 3.0 kW

Only 8 item(s) left in stock
  • Manufacturer: Lenze

  • Product No.: EVF9324-EV

  • Country of origin:Niemcy

  • Product Type: Variable frequency drives

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 5500g

  • Dimensions: 10,20cm x 40,60cm x 25,40cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Product Overview

The EVF9324-EV (EVF9324EV) is a high-precision 9300-series vector frequency inverter designed for sophisticated motion control and speed regulation in demanding industrial sectors. This 3.0 kW (4.0 HP) drive is specifically engineered for applications requiring high dynamic response and torque accuracy, such as precision winding, synchronized conveyor systems, and complex material processing. Operating on a 400 / 480 V mains connection, the EVF9324-EV excels in reducing mechanical wear and enhancing energy efficiency across the drivetrain. This specific "EV" variant is designed without internal interference suppression measures, providing a specialized solution for systems where external filtering is already centralized or where specific grounding architectures are required. Manufactured in Germany, it serves as a critical bridge for maintaining legacy 9300-series installations, ensuring maximum uptime in plants transitioning toward next-generation automation.

Technical Configuration

The EVF9324-EV utilizes Lenze's advanced field-oriented control (FOC) algorithm, allowing for near-servo performance from standard asynchronous motors. The internal architecture features high-speed digital signal processing to manage complex ramp profiles and torque limits in real-time. Without integrated RFI/EMI suppression, this unit offers a simplified power stage that is often preferred in large-scale installations where a common DC bus or centralized line filters are utilized. It supports a variety of plug-in modules for communication (CAN, PROFIBUS, INTERBUS) and feedback (resolver, encoder), allowing it to act as a versatile node within a decentralized control network. The rugged IP20 housing is optimized for vertical mounting, ensuring reliable thermal management through its integrated aluminum heatsink.

Technical Specifications

Feature Specification
Model EVF9324-EV
Brand Lenze
Series 9300-Series Vector
Rated Power 3.0 kW (4.0 HP)
Input Voltage 3 x 400 / 480 VAC
Output Current 7.0 A (at 400 V)
Dimensions 10.20 x 40.60 x 25.40 cm
Weight 5.50 kg
Suppression Without internal interference suppression
Protection Degree IP20
Operating Temp 0 to +45 deg C
Product Phase Phase-Out

Technical FAQs

Why would I choose the EVF9324-EV (without suppression) over a standard version?

The EV variant is often selected for systems utilizing external line filters or in environments with specific leakage current requirements (such as IT networks). Removing internal suppression components can prevent unwanted tripping of sensitive residual current devices (RCDs) while allowing for customized EMI management.

What is the maximum output frequency for the 9300-series vector drives?

The EVF9324-EV typically supports an output frequency up to 600 Hz, depending on the control mode and switching frequency settings. This makes it suitable for high-speed spindle applications as well as standard 50/60 Hz motor control.

Is it possible to transfer parameters from a failed 9300 drive to a new EVF9324-EV?

Yes. Parameters can be transferred using the XT keypad (EMZ9371BC) or via PC software (GDC) using an 2102 IB communication module. This ensures that custom tuning, torque limits, and I/O configurations are preserved during hardware replacement.


Engineering & Installation Guide

  • External Filtering Requirements: Since the EVF9324-EV does not include internal interference suppression, it is critical to install an external mains filter (RFI filter) if the installation must comply with EN 61800-3 standards. Failure to provide adequate external filtering may lead to high-frequency interference affecting sensitive control signals and neighboring electronic equipment.

  • Vertical Mounting and Airflow: The unit must be mounted vertically on a flat, non-flammable surface. Maintain a minimum vertical clearance of 100 mm at the top and bottom. The 5.50 kg frame utilizes significant convective cooling; ensure that cabinet fans are positioned to provide a continuous flow of cool air across the heatsink fins.

  • DC Bus Safety: Before performing any wiring or maintenance on the power terminals (L1, L2, L3 or +UG, -UG), disconnect the mains and wait a minimum of 5 minutes. Use a multimeter to verify that the DC bus voltage has discharged to a level below 50 VDC. The large internal capacitors can hold a lethal charge long after the AC supply is removed.

 

Key Features:

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Szaro-biały
Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...