Engineered for precise speed and torque regulation of three-phase asynchronous motors, the Lenze EVF8244-E frequency inverter provides robust control within the 8200-series architecture. This high-performance AC drive is designed to optimize energy consumption and maintain process stability in demanding industrial automation environments, supporting motors rated up to 4 HP (3.0 kW) at 460V.

Key Features

  • Precise Motor Management: Advanced electronic control algorithms ensure stable speed control and dynamic torque response under varying load conditions.
  • Modular Design: Seamlessly integrates with various plug-in communication and I/O modules from the Lenze 8200 range.
  • Energy Efficiency: Optimizes motor power consumption during partial-load operations.
  • Robust Construction: Built to withstand harsh industrial environments, ensuring long-term operational reliability.

Applications

  • Conveyor systems and material handling lines
  • Industrial pumps, fans, and ventilation systems
  • Packaging machinery and processing equipment
  • Machine tool auxiliary drives and positioning systems

Technical Specifications

Manufacturer Lenze
Model / SKU EVF8244-E
Alternative Item Code 33.8244_E
Series 8200-series
Product Type AC Drive / Frequency Inverter
Power Rating 3.0 kW / 4.0 HP
Rated Input Voltage 3-phase 400 V AC to 460 V AC
Product Lifecycle Phase Phase-Out (Legacy Support Available)
Dimensions (W x H x D) 10.20 cm x 40.60 cm x 25.40 cm
Shipping Weight 5.10 kg
Commodity Code 85044095

Empirical Engineering Insights

Alternative Models & Compatibility

The EVF8244-E belongs to the legacy 8200 Vector family. When replacing this unit in existing panels, note that modern alternatives like the Lenze i550 series do not share the same physical footprint or terminal configurations. Retaining exact spares like the EVF8244-E avoids costly mechanical panel modifications and PLC program rewrites.

Application Pitfalls & Engineering Notes

This drive relies heavily on vertical convection cooling. In enclosed control panels, ensure a minimum clearance of 100 mm above and below the unit. If ambient temperatures inside the enclosure exceed 40 degC, the continuous output current must be derated to prevent thermal overload faults.

Commissioning & Wiring Tips

Parameterization can be performed using the EMZ8201BB keypad module or via the LECOM interface using Global Drive Control (GDC) software. Always ensure that the motor cable is shielded and that the shield is grounded with a low-impedance connection directly at the drive's mounting plate to mitigate electromagnetic interference (EMI).

Installation Guidelines

CRITICAL WARNING: Hazardous electrical voltages remain present in the DC bus capacitors (terminals UG and +UG) for up to 5 minutes after disconnecting the mains supply. Verify that the DC bus voltage has discharged to 0 VDC using a calibrated multimeter before performing any wiring, terminal modifications, or maintenance.
1

Mount the drive vertically on a flat, vibration-free mounting plate inside a suitable industrial enclosure.

2

Connect the protective earth (PE) conductor to the designated grounding terminal prior to making any other electrical connections.

3

Wire the 3-phase AC mains input to terminals L1, L2, and L3 using appropriately sized branch circuit protection.

4

Connect the shielded motor cable to output terminals U, V, and W, ensuring the shield clamp is securely fastened to the ground plane.

What is the power rating of the Lenze EVF8244-E?

The EVF8244-E is rated for motors up to 3.0 kW (4.0 HP) operating on a 3-phase 400V to 460V AC supply.

How do I configure parameters on this legacy 8200-series drive?

Parameters can be adjusted using the EMZ8201BB plug-in keypad module or via a PC connection using Global Drive Control (GDC) software and a LECOM interface adapter.

What is the direct modern replacement for the EVF8244-E?

There is no direct physical drop-in replacement. The Lenze i550 series is the modern equivalent, but it requires mechanical panel adaptation and rewiring of control terminals.

How long should I wait after power-down before servicing the drive?

You must wait at least 5 minutes to allow the internal DC bus capacitors to fully discharge. Always verify 0 VDC at the DC terminals with a multimeter before touching connections.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Niemcy

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...