1 z 2

Omron CJ1G-CPU42P CJ1G Series Loop Control CPU Unit

Omron CJ1G-CPU42P CJ1G Series Loop Control CPU Unit

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CJ1G-CPU42P

  • Country of origin:Japonia

  • Product Type: Loop Control CPU Unit

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

The Omron CJ1G-CPU42P is a high-performance central processing unit integrating sequence and loop control functionality within the SYSMAC CJ1 programmable controller family. Engineered specifically for process automation applications, this engine combines high-speed ladder logic execution with advanced analog regulation capabilities, enabling the block processing of PID algorithms directly inside the processor. By executing sequence control and process loops concurrently, the module streamlines system overhead and eliminates the need for standalone regulatory controllers. It features an onboard peripheral port, an integrated RS-232C interface, and flash memory backup to safeguard user data. The unit maintains complete structural and functional compatibility with standard CJ-series discrete, analog, and communication network interfaces.

Features

  • Integrated dual engine executing ladder logic and regulatory process control concurrently.
  • Embedded loop control function blocks for PID regulation, cascade loops, and feed-forward operations.
  • Dedicated internal memory area for scaling and allocating process variables.
  • Built-in RS-232C port and high-speed peripheral tool interface.
  • Compact, slotless design optimizing physical space configurations along the din-rail track.
  • Flash memory backup for step programs and loop configurations, preventing data loss during power outages.
  • Direct configuration compatibility with standard CJ-series high-density discrete and specialized analog I/O modules.

Applications

  • Temperature profile management and thermal regulation in chemical reactors.
  • Flow rate dosing and parameter monitoring in water treatment infrastructure.
  • Pressure and level regulation loops in specialized fluid distribution systems.
  • Batch processing and material blending controls in food production lines.
  • Extrusion line temperature and variable motor drive coordination.

Technical Specifications

Performance and System Capacity

Parameter Specification
Program Capacity 20K steps
Data Memory Capacity 64K words
Number of Loop Control Blocks Up to 300 blocks
LD Instruction Execution Speed 0.04 $\mu$s
Maximum I/O Capacity 1,280 points
Maximum Number of Expansion Racks 3 Racks

Communication and Interfaces

Parameter Specification
Built-in Peripheral Port Proprietary tool bus connection
Built-in Serial Port RS-232C (D-Sub 9-pin female connector)
Serial Protocols Supported Host Link, NT Link, No-protocol serial communication
Extended Storage Interface CompactFlash card slot for memory logging and parameter storage

Electrical and Environmental

Parameter Specification
Current Consumption 0.91 A at 5 VDC
Operating Ambient Temperature 0 to 55 Celsius
Storage Ambient Temperature -20 to 75 Celsius
Ambient Operating Humidity 10% to 90% RH (non-condensing)
Atmosphere Must be free from corrosive gases

Connections / Interfaces

Port / Interface Connector Type Function
Peripheral Port Custom Omron Connector Direct connection for CX-Programmer or CX-Process configuration tools
RS-232C Port D-Sub 9-pin (Female) Interfacing local HMI displays, specialized modems, or SCADA links
Memory Card Slot CompactFlash (CF) Slot Storing loop parameters, step program backups, and CSV format logs

Installation Guidelines

  • Module Assembly: Guide the upper alignment hook of the CPU onto the standard 35 mm DIN rail immediately adjacent to the CJ-series system power supply module. Push down the top and bottom sliding locks until they lock securely.
  • Functional Earthing: Establish a dedicated connection using a short electrical conductor ($2\text{ mm}^2$ minimum thickness) from the functional ground terminal on the power supply module to the main panel ground bar.
  • Thermal Management: Maintain an unobstructed boundary gap of at least 20 mm above and below the module ventilation slots to ensure passive convection airflow.
  • Signal Shielding: Ensure analog loop instrumentation wires and low-voltage sensor lines are shielded. Route them separate from heavy motor mains or power line cables to prevent induction noise.
  • Hot-Swapping Restriction: Always isolate the entire rack power supply circuit before mounting, interlocking, or removing the CPU assembly.

FAQ

  • What differentiates this model from standard CJ1G processors?
  • The "P" suffix signifies integrated process loop control, enabling the deployment of dedicated process control blocks alongside traditional ladder logic step configurations.
  • What engineering software tools are required to program this unit?
  • CX-Programmer manages standard ladder sequence logic, while CX-Process is utilized to engineer the internal loop control blocks.
  • Is a battery backup strictly required to keep the step logic safe?
  • No, the user program and loop blocks write automatically to internal non-volatile flash memory, securing the logic against total power loss.
  • Can PID tuning parameters be modified during active system operation?
  • Yes, loop gains, integration times, and parameter limits can be adjusted online via connected software tools or industrial HMIs.
  • Does this CPU module support standalone operation without a power module?
  • No, it must be interlocked onto a backplane assembly powered by a compatible left-side CJ-series system power supply module.
  • What type of memory card does the onboard slot receive?
  • It accommodates standard Omron-certified industrial CompactFlash cards for data logging and system backups.
  • What is the maximum number of local expansion racks supported by this processor?
  • The system topology supports up to 3 local expansion racks linked via standard expansion cables.
  • What communication modes can be configured on the built-in D-Sub port?
  • The port handles standard Host Link, NT Link (1:N mode), or No-protocol ASCII configurations for custom serial interfacing.
  • How does the module indicate internal loop execution faults?
  • Hardware indicators such as the front-panel ERR/ALM LED flash or light up steady to signal fault conditions, which can be diagnosed through allocated error flags.
  • What approach should be followed if electromagnetic noise impairs signal tracking?
  • Verify that the main power supply ground terminal links directly to a clean industrial ground, and check that all analog cable shields are connected on the panel end.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Color pattern
Czarny Szaro-biały
Country of origin
Japonia
Power source
Zasilany prądem zmiennym Zasilanie prądem stałym

Ostatnio oglądane produkty

Wiedza techniczna

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...