1 z 1

Omron F3SJ-E0465N25 F3SJ Series Safety Light Curtain

Omron F3SJ-E0465N25 F3SJ Series Safety Light Curtain

Only 4 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: F3SJ-E0465N25

  • Country of origin:Japonia

  • Product Type: Safety Light Curtains

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Engineered to deliver simplified, Type 4 machine guarding in automated environments, the Omron F3SJ-E0465N25 provides reliable optoelectronic presence sensing. This Easy-type (F3SJ-E) safety light curtain features a 465 mm protective height and a 25 mm detection capability specifically optimized for hand protection. It operates on an NPN output configuration, making it compatible with sinking logic safety controllers and relays. By focusing on essential on-off safety functions, it minimizes wiring complexity and setup time while maintaining compliant industrial safeguarding performance.

Key Features

  • Type 4 Safety Rating: Compliant with international safety standards including EN ISO 13849-1 PL e and IEC 61508 SIL3.
  • Optimized Resolution: 25 mm beam gap designed specifically for reliable hand and arm detection.
  • NPN Output Architecture: Twin NPN solid-state outputs (OSSDs) for seamless integration with sinking control systems.
  • Simplified Wiring: Reduced wiring design using standard M12 connections, omitting complex auxiliary functions to prevent field configuration errors.
  • Robust Optical Range: Operating scanning range of 0.2 m to 7.0 m, covering a wide array of machine entry points.

Applications

  • Robotic Workcells: Guarding primary access areas and perimeter entry points of robotic arms.
  • Packaging and Conveying: Presence detection and worker protection around automated palletizers and cartooning systems.
  • Assembly Lines: Point-of-operation safeguarding on semi-automated workstations and pneumatic presses.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number F3SJ-E0465N25
Series Type F3SJ-E (Easy Type)
Safety Category Type 4, PL e, SIL 3
Protective Height 465 mm
Detection Capability 25 mm diameter (Hand)
Number of Beams 22
Beam Gap 20 mm
Operating Range 0.2 m to 7.0 m
Output Type NPN (x2 OSSD outputs)
Supply Voltage (Vs) 24 VDC plus/minus 20% (SELV/PELV)
Light Source Infrared LED (870 nm)
Current Consumption (Emitter) 41 mA max.
Current Consumption (Receiver) 40 mA max.
Enclosure Rating IP65 (IEC 60529)
Net Weight 1.8 kg
Shipping Weight (Calculated) 3.0 kg

Connections and Interfaces

M12 Connector Pin Emitter Function Assignment Receiver Function Assignment
Pin 1 (Brown) +24 VDC Power Input +24 VDC Power Input
Pin 2 (White) Not Used (NC) OSSD 2 Output
Pin 3 (Blue) 0 VDC Power Input 0 VDC Power Input
Pin 4 (Black) Test Input OSSD 1 Output

Empirical Engineering Insights

Alternative Models & Compatibility

The F3SJ-E "Easy" series is designed for straightforward on-off detection. Unlike the Advanced (F3SJ-A) and Basic (F3SJ-B) series, the F3SJ-E series does not support series connection (cascading) for multi-sided safety fields. Emitters and receivers must be replaced in identical matched pairs; pairing an F3SJ-E emitter with an F3SJ-B receiver will result in a synchronization fault. Always verify the prefix/suffix matches during drop-in replacements to prevent field pairing errors.

Application Pitfalls & Engineering Notes

Because this model features NPN outputs (N25 suffix), it cannot be wired directly to PNP-only safety monitoring modules. Integrating this light curtain into a PNP-based system requires an external NPN-to-PNP converter or a dedicated safety relay compatible with dual sinking inputs. Additionally, ensure the structural mounting is completely rigid; thermal expansion or frame vibrations can easily disrupt optical alignment across the 7.0-meter operating threshold, triggering intermittent OSSD dropouts.

Commissioning & Wiring Tips

To maintain complete electromagnetic immunity, execute correct shielding procedures. The cable shield must be grounded at the control panel chassis. Avoid routing the emitter/receiver cables in parallel with high-power motor lines or variable frequency drive (VFD) output cables. When configuring the Test Input on the emitter, wire it to an external control device to periodically verify system shut-off function as mandated by local safety standards.

Installation Guidelines

CRITICAL WARNING:

Ensure all primary electrical supply lines are locked and tagged out prior to physical installation. De-energize the entire cabinet and verify zero electrical potential. Failure to do so can result in permanent device damage, immediate optical array failure, or severe injury from unexpected machinery start-up.

1
Mechanical Alignment: Securely mount the emitter and receiver directly parallel to each other at the exact height required, ensuring both units sit completely plumb on their vertical axes.
2
Cable Connection: Connect the 4-pin M12 cables to both the emitter and receiver. Route cables using dedicated low-voltage conduit to avoid electromagnetic noise.
3
Optical Verification: Apply 24 VDC power and check the diagnostic LEDs on the receiver. Rotate the housings slightly to find the optimal optical sweet spot where the alignment indicators glow solid green.

Can the F3SJ-E0465N25 be cascaded for multi-segment guarding?

No, the F3SJ-E Easy Series does not support cascading. For multi-segment or serial connections, select the F3SJ-B (Basic) or F3SJ-A (Advanced) series.

What does the 'N25' suffix represent in the model code?

The 'N' denotes NPN solid-state safety outputs (sinking logic), and '25' indicates a 25 mm detection capability designed specifically for industrial hand protection.

How do I troubleshoot intermittent optical alignment dropouts?

Check structural rigidity to eliminate machine frame vibrations. Additionally, ensure there are no highly reflective metal surfaces within the optical path angle limit of the emitter and receiver.

Can this unit be wired to a PNP safety controller?

It cannot be wired directly to PNP inputs because of its NPN sinking output stage. An intermediate NPN-to-PNP safety interface relay module must be used.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Japonia

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...