1 z 1

Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter

Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 8800D Vortex Flowmeter

Only 4 item(s) left in stock
  • Manufacturer: Rosemount

  • Product No.: 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8

  • Country of origin:Stany Zjednoczone

  • Product Type: Vortex Flowmeters

  • Payment: T/T, Western Union

  • Weight: 136000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Designed for highly reliable steam, liquid, and gas flow measurement, the Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8 is an industrial inline vortex flowmeter utilizing a non-clogging sensor design to eliminate impulse lines and potential leak points. This specific configuration features a massive 12-inch (300 mm) flanged body constructed of robust CF-3M cast stainless steel and 316 wrought stainless steel wetted materials, capable of handling demanding industrial process environments.

The system is equipped with 4-20 mA digital electronics running the HART communication protocol, enabling seamless diagnostic monitoring and configuration. To ensure operator clarity on-site, a high-visibility M5 LCD display is built directly into the rugged stainless steel transmitter housing, which is configured with two M20 x 1.5 conduit entries. For safety compliance, this model comes certified with ATEX dual protection—both Flameproof (E1) and Intrinsic Safety (I1)—and includes comprehensive Q4 calibration and Q8 material traceability documentation.

Features

  • All-Welded Design: Eliminates internal gaskets, ports, and bypass lines, preventing process bypass and potential leak paths.
  • Adaptive Digital Signal Processing: Provides reliable flow signal tracking while filtering out ambient process vibration.
  • ATEX Dual Certification: Flameproof and Intrinsic Safety approvals for deployment in classified hazardous industrial zones.
  • Local Operator Interface: Includes an integrated M5 LCD indicator showing process variables and diagnostics.
  • Configurable Alarms: Dual NAMUR C4 (high alarm) and CN (low alarm) saturation and alarm values protect process equipment.
  • Quality Documentation: Ships with ISO 10474 3.1/EN 10204 3.1 calibration and material traceability certificates.

Applications

  • High-capacity steam utility lines and boiler feedwater monitoring.
  • Industrial gas distribution and compressed air management.
  • Chemical and petrochemical process fluid allocation.
  • Power plant cooling water and condensate loop measurement.

Technical Specifications

ManufacturerPart Number / ModelMeter StyleLine SizeWetted MaterialsFlange Class and ConnectionProcess Temperature RangeHousing MaterialConduit EntriesOutputsCalibration TypeHazardous Area ApprovalsDisplayAlarm ConfigurationQuality CertificatesDevice WeightShipping Weight
Rosemount (Emerson)
8800DF120SA1N7D1E1I1M5C4CN7Q4Q8
F - Standard flanged body style
12 inch (300 mm)
CF-3M Cast Stainless Steel / 316 Wrought Stainless Steel (316/316L)
ASME B16.5 RF Class 150
-40 to +450 degF (-40 to +232 degC)
Stainless steel housing
Two M20 x 1.5 conduit entries
4-20 mA digital electronics (HART Protocol)
Flow calibration
ATEX Flameproof (E1) & ATEX Intrinsic Safety ia/ic (I1)
M5 LCD indicator
C4 NAMUR high alarm, CN NAMUR low alarm and saturation values
ISO 10474 3.1/EN 10204 3.1 Calibration (Q4) & Material Traceability (Q8)
298 lb (135 kg)
136 kg

Connections and Interfaces

Terminal / Port Functional Assignment
PWR/COMM + Positive loop power supply input and HART digital communications
PWR/COMM - Negative loop power supply input and common return
TEST + / - Loop current verification terminal (allows measurement without breaking loop)
Internal Ground Electronic housing safety ground termination point
External Ground External chassis equipotential grounding lug

Installation Guidelines

  • Straight Pipe Runs: To ensure accurate flow measurement, install the meter with a minimum of 10 nominal pipe diameters upstream and 5 nominal pipe diameters downstream of straight pipe, free from valves or fittings.
  • Orientation: Can be installed in horizontal, vertical, or inclined piping. Vertical mounting with upward process flow is recommended to keep the sensor completely flooded.
  • Conduit Sealing: Install appropriate certified cable glands or conduit seals in the M20 x 1.5 entries to maintain the NEMA 4X / IP66/67 environmental rating.
  • Grounding: Always ground the transmitter housing to earth using the internal or external grounding screw terminals in accordance with local hazardous area codes.

Compliance and Certifications

  • ATEX Directive compliance for hazardous area installations.
  • Flameproof certification: ATEX II 2 G Ex d IIB+H2 T6 Gb (E1 option).
  • Intrinsic Safety certification: ATEX II 1 G Ex ia IIC T4 Ga (I1 option).
  • ISO 10474 / EN 10204 Type 3.1 material and calibration verification.

What is the process line size for the Rosemount 8800DF120SA1N7D1E1I1M5C4CN7Q4Q8?

This model is configured for a 12-inch (300 mm) process pipe line size with standard flanged body connections.

What process connection rating does this flowmeter use?

It is rated for ASME B16.5 RF Class 150 flanged process connections (option code A1).

What wetted materials are used in construction?

The wetted components are made of 316 wrought stainless steel and CF-3M cast stainless steel.

Which hazardous area certifications are included in this flowmeter configuration?

This flowmeter comes certified with ATEX Flameproof (E1) and ATEX Intrinsic Safety ia/ic (I1) dual approvals.

What quality certificates are provided with the Q4 and Q8 options?

The Q4 option includes a Calibration Certificate per ISO 10474 3.1/EN 10204 3.1, while the Q8 option provides a Material Traceability Certificate per ISO 10474 3.1/EN 10204 3.1.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Stany Zjednoczone

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...