1 z 1

Schneider Electric 170AAO92100 Modicon Momentum Analog Output Module

Schneider Electric 170AAO92100 Modicon Momentum Analog Output Module

Only 6 item(s) left in stock
  • Manufacturer: Schneider Electric

  • Product No.: 170AAO92100

  • Country of origin:Francja

  • Product Type: Analog Output Modules

  • Payment: T/T, Western Union

  • Weight: 380g

  • Dimensions: 26.0 x 18.0 x 5.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Ilość
Pokaż kompletne dane

Description

Executing precise current loop control in distributed control architectures, the Schneider Electric 170AAO92100 serves as a high-reliability 4-channel analog output module within the Modicon Momentum series. This hardware component converts digital control signals from the processor or network adapter into 4-20 mA analog outputs, allowing seamless interface connection to control valves, variable speed drives, actuators, and analog indicators. Engineered for modular flexibility, this unit clips directly onto a Momentum communication adapter or processor base, reducing field wiring complexity and optimizing cabinet panel footprint.

Features

  • Four Independent Channels: Multi-channel output capabilities manage up to four distinct 4-20 mA field loops simultaneously.
  • Modular Architecture: Integrates directly with Modicon Momentum network adapters (including Modbus TCP, Modbus Plus, and PROFIBUS) or local processor adapters.
  • High Resolution Conversion: Accurate 12-bit digital-to-analog converter ensures fine-grained control over external analog field devices.
  • Hot-Swapping Capability: Supports field-level servicing without interrupting system-wide communications when combined with compatible bases.
  • Integrated Status Diagnostics: Front-panel LED indication simplifies hardware status validation and channel fault isolation during active commissioning.

Applications

  • Modulating Control Valves: Precise positioning of pneumatic and electrical valves in chemical and water treatment facilities.
  • VFD Speed Referencing: Dynamic control over variable frequency drive speeds in conveyor systems and pumping stations.
  • Remote Field Distribution: Standardized analog field signaling in decentralized I/O networks spanning large factory floors.
  • SCADA Integration: Local analog signal reconstruction for instrumentation displays and environmental recording systems.

Technical Specifications

Parameter Specification Value
Manufacturer Schneider Electric
Part Number / SKU 170AAO92100
Product Range Modicon Momentum
Module Type Distributed Analog Output Module
Number of Outputs 4 Channels
Output Range 4 to 20 mA
Resolution 12-bit
External Power Requirement 24 VDC (Loop Power)
Country of Origin France
Commodity Code 85381000
Shipping Weight (Calculated) 0.38 kg
Package Dimensions (Calculated) 26.0 x 18.0 x 5.5 cm

Empirical Engineering Insights

Alternative Models & Compatibility

This module functions as a direct drop-in replacement across legacy Momentum field bus architectures. When migrating older systems to modern Modicon M580 controllers via Ethernet adapters, confirm that the network adapter head module firmware supports the 12-bit diagnostic registers mapped by the 170AAO92100 to prevent system configuration mismatches during hardware assembly scans.

Application Pitfalls & Engineering Notes

A common point of failure in field installations is the loss of external 24 VDC loop power. While the internal logic of the module remains powered through the network base adapter (allowing bus communication to remain active), a failure of the external loop power supply drops outputs to 0 mA. This can cause downstream devices to interpret the loss of signal as a broken wire fault (below the 4 mA limit threshold).

Commissioning & Wiring Tips

Always route the 4-20 mA field cables away from high-voltage AC motor lines to prevent electromagnetic induction from distorting output values. Ensure that cable shielding is terminated strictly at the local panel single-point ground. Shield grounding at both ends should be avoided to eliminate ground loop current interferences.

Installation Guidelines

CRITICAL WARNING: De-energize all primary, secondary, and external loop power sources connected to the Momentum base before mounting or removing the module. Failure to fully isolate field-level power can cause internal circuit damage or generate unexpected physical actuator movement in online process hardware.
1
Align the rear locating pins of the 170AAO92100 with the corresponding mounting slots on the pre-installed Momentum terminal base or communication adapter.
2
Press the module firmly down until the side locking tabs fully engage, confirming a secure structural and electrical connection to the underlying unit.
3
Terminate the external 4-20 mA signal loops and the auxiliary 24 VDC power supply to the designated terminals, adhering to the torque specifications on the connection diagram.
4
Apply external 24 VDC power followed by backplane network power, and verify the physical LED indicator sequence to ensure error-free channel initialization.

What is the primary function of the 170AAO92100 module?

It acts as a distributed 4-channel analog output module, converting internal digital signals from a Modicon Momentum control network into physical 4-20 mA current loops to control field hardware.

Does this module require an external power supply for the current loops?

Yes, an external 24 VDC power supply must be wired to the module to supply power to the individual 4-20 mA analog loops.

What network communication protocols are compatible with this module?

It is compatible with any standard Modicon Momentum communication adapter base, including Modbus TCP/IP, Modbus Plus, PROFIBUS DP, and INTERBUS.

What is the analog output resolution of each channel?

The module utilizes a high-accuracy 12-bit digital-to-analog converter (DAC) across its operational 4 to 20 mA range.

Globalna ekspresowa wysyłka

  • Standardowa dostawa: 4-6 dni roboczych za pośrednictwem DHL, FedEx i UPS.
  • Ekspresowa wysyłka: Wysyłka tego samego dnia dla zamówień dostępnych w magazynie złożonych przed godziną 14:00 (GMT+8).
  • Globalne pokrycie: Obsługujemy ponad 150 krajów, w tym szybką dostawę do Arabii Saudyjskiej i ZEA.

Zwroty i gwarancja

  • 30-dniowa gwarancja: Zwroty przyjmowane są dla produktów dostępnych w magazynie, w oryginalnym, fabrycznie zapieczętowanym opakowaniu.
  • 12-miesięczna gwarancja: Każdy komponent przemysłowy objęty jest naszą profesjonalną gwarancją techniczną.

Zamówienia są przetwarzane i dostarczane od poniedziałku do piątku (z wyłączeniem dni świątecznych).


Aby poznać pełne warunki kwalifikowalności, opłaty za przyjęcie towaru z powrotem oraz szczegóły dotyczące zwrotów międzynarodowych, prosimy zapoznać się z naszym oficjalnym Polityka zwrotów i zwrotu pieniędzy .

TECHNICAL SPECIFICATIONS

Country of origin
Francja

Ostatnio oglądane produkty

Wiedza techniczna

Siłowniki elektryczne zaprojektowane do zastąpienia systemów hydraulicznych: praktyczny przewodnik po automatyce przemysłowej

Ten artykuł wyjaśnia, jak zintegrowane siłowniki elektryczne, takie jak seria e-Actuator firmy SMC, rewolucjonizują przemysłową kontrolę ruchu, zastępując tradycyjne systemy pneumatyczne i...

Operacje matematyczne z wykorzystaniem OpenPLC w zastosowaniach automatyki przemysłowej

Ten artykuł wyjaśnia, jak systemy PLC wykonują podstawowe operacje matematyczne, takie jak dodawanie, odejmowanie, mnożenie, dzielenie, modulo oraz potęgowanie w automatyce przemysłowej. Pokazuje,...

Zaawansowana logika boolowska w programowaniu PLC za pomocą FBD: praktyczne zastosowania przemysłowe wykraczające poza podstawową logikę

Artykuł wyjaśnia kilka zaawansowanych funkcji logiki boolowskiej stosowanych w programowaniu PLC, wykraczających poza podstawowe operacje AND, OR i NOT. Omawia, jak narzędzia takie jak tabele prawdy,...

Logika boolowska w programowaniu PLC: Zrozumienie bramek logicznych FBD

Logika boolowska jest podstawą każdego programu PLC. Od prostych sterowań maszyn po złożone systemy automatyki przemysłowej, bramki logiczne decydują o tym, jak sterowniki reagują na zmieniające się...

Szczegółowy przewodnik po przemysłowych zaporach sieciowych i segmentacji sieci OT

Przemysłowe zapory sieciowe odgrywają kluczową rolę w cyberbezpieczeństwie OT, chroniąc sieci PLC, DCS i SCADA poprzez segmentację, kontrolę ruchu przychodzącego/wychodzącego oraz integrację IDS/IPS...

Przewodnik po chwytakach robotycznych: od delikatnego manipulowania po ciężką automatykę

Nowoczesne chwytaki robotyczne ewoluują poza tradycyjne mechaniczne szczęki. Od systemów adhezyjnych inspirowanych gekonem i miękkich chwytaków spożywczych po narzędzia magazynowe zasilane sztuczną...