Danfoss

060G2109 Danfoss AKS 33 Refrigeration Pressure Transmitter

SKU 060G2109

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 060G2109

  • Country of origin:United States

  • Product Type: Pressure Transmitter | AKS 33

  • Payment: T/T, Western Union

  • Weight: 168g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 060G2109 (060G2109) is a high-precision pressure transmitter from the Danfoss AKS 33 series, specifically engineered for commercial and industrial refrigeration applications. This robust sensor converts measured pressure into a standard 4 to 20 mA current signal, facilitating seamless integration with PLC systems and electronic controllers. Designed to perform in the harshest environments, the 060G2109 features a sealed gauge reference and is highly resistant to moisture, temperature fluctuations, and vibration. Whether utilized in air conditioning units, cold storage facilities, or chiller plants, this transmitter ensures precise suction or discharge pressure monitoring, which is critical for optimizing compressor performance and preventing system-wide failures due to refrigerant leaks or mechanical overpressure.

Technical Configuration

The AKS 33 series is built to provide reliable data in demanding HVAC-R circuits where signal stability is paramount.

  • Signal Integrity: The 4 to 20 mA output signal is highly resistant to electromagnetic interference, ensuring accurate data transmission even over long cable runs in industrial machine rooms.

  • Environmental Resilience: With an IP65 enclosure rating and a wide medium temperature range of -40 to 85 deg C, the sensor handles extreme cold and heat without compromising structural integrity.

  • Electrical Interface: Features an angular connector compliant with EN 175301-803-A, providing a secure, standardized connection that simplifies field replacement and maintenance.

  • Pressure Safety: The unit is rated for a maximum overload pressure of 40 bar (580 psi), offering a significant safety margin against pressure spikes within the refrigerant loop.

  • Advanced Compensation: Includes internal temperature compensation between -30 and 40 deg C to ensure that thermal drift does not affect the accuracy of the pressure readings.

Technical Specifications

Feature Specification
Model 060G2109
Brand Danfoss
Series AKS 33
Pressure Reference Sealed Gauge
Output Signal 4 - 20 mA
Electrical Connection Angular Connector (EN 175301-803-A)
Enclosure Rating IP65
Overload Pressure Max 40 bar (580 psi)
Medium Temp Range -40 to 85 deg C
Compensated Temp Range -30 to 40 deg C
Weight 0.168 kg
Shipping Weight 1.0 kg

Technical FAQs

Is the 060G2109 compatible with all common refrigerants?

Yes, the AKS 33 series is designed to be compatible with most CFC, HCFC, and HFC refrigerants. However, for specialized or highly corrosive media, engineers should verify the compatibility of the internal sensing element and O-ring materials with the specific chemical composition.

What is the benefit of the "Sealed Gauge" reference in this model?

The sealed gauge reference means the sensor is not affected by variations in atmospheric pressure. This is particularly useful in refrigeration systems located at high altitudes or in environments where the sensor is exposed to significant ambient pressure changes, ensuring the pressure reading remains consistent.

How does the IP65 rating protect the sensor in cold storage?

The IP65 rating ensures the transmitter is dust-tight and protected against water jets. In cold storage environments, this prevents moisture ingress caused by condensation or wash-down cycles from damaging the internal electronics, thereby preventing signal drift or short circuits.


Engineering & Installation Guide

  • Moisture Prevention (Drip Loop): When installing the 060G2109, always ensure the electrical cable forms a "drip loop" before entering the angular connector. This prevents condensed moisture on the cable from running directly into the connection point, preserving the IP65 seal and preventing terminal corrosion.

  • Vibration Mitigation: While the AKS 33 is designed for industrial use, mounting it directly onto a high-vibration compressor housing should be avoided if possible. Instead, mount the sensor on a rigid bracket and use a capillary tube or flexible hose for the pressure connection to decouple the sensor from high-frequency mechanical vibration.

  • Wiring Precision: Use the standard EN 175301-803-A pinout for current loop wiring. Ensure the shield of the signal cable is grounded only at the controller side to avoid ground loops, which can introduce noise into the 4 to 20 mA signal and cause erratic pressure readings in the PLC interface.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...