Danfoss

084G2106 Danfoss EMP 2 Heavy-Duty Pressure Transmitter

SKU 084G2106

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 084G2106

  • Country of origin:United States

  • Product Type: Controles Industriales Pressure Transmitter

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The 084G2106 (084G2106) is a high-performance industrial pressure transmitter from the Danfoss EMP 2 series, engineered for reliable monitoring in demanding maritime and heavy industrial applications. With a pressure range of 0 to 4 bar (0 to 58.02 psi), this gauge reference sensor is designed to provide stable current signals for engine control, boiler feed water, and hydraulic oil systems. The 084G2106 features a robust G 1/2 process connection and an IP65 rated enclosure, ensuring consistent performance in high-vibration environments such as ship engine rooms or power plants. By delivering typical accuracy of 0.5 percent FS, this transmitter plays a critical role in preventing overpressure events and maintaining optimal fluid dynamics, directly contributing to extended equipment service life and reduced maintenance intervals.

Technical Configuration

The EMP 2 series is recognized for its heavy-duty construction and long-term stability in harsh media environments.

  • Signal Output: Utilizes a standard 4 to 20 mA current loop, optimized for long-distance transmission with low susceptibility to electromagnetic interference.

  • Clipping Protection: Features high and low clipping levels (22.4 mA and 3.6 mA) to provide clear diagnostic signaling for sensor out-of-range conditions or faults.

  • Electrical Interface: Equipped with a Pg 13.5 terminal block connection, allowing for secure and straightforward field wiring within the IP65 protective housing.

  • Media Compatibility: Designed for medium temperatures ranging from -10 to 70 deg C, with a non-flush diaphragm suitable for clean gases and liquids.

  • Safety Margin: Boasts a maximum overload pressure of 8 bar, double its operating range, to protect the sensing element from hydraulic spikes and transient pressure surges.

Technical Specifications

Feature Specification
Model 084G2106 (EMP 2-1611-F6CD24-2)
Brand Danfoss
Pressure Range 0 to 4 bar (Gauge)
Output Signal 4 - 20 mA
Supply Voltage 12 - 32 VDC
Accuracy (Typical) 0.5 percent FS
Process Connection G 1/2 (EN 228-1)
Enclosure Rating IP65
Response Time Max 4 ms
Compensated Temp 0 to 70 deg C
Shipping Weight 2.5 kg

Technical FAQs

How do the clipping levels assist in system troubleshooting?

The 084G2106 uses a 3.6 mA low clipping and 22.4 mA high clipping level. If your PLC detects a signal below 3.8 mA or above 20.5 mA, it indicates that the transmitter is experiencing an over-range condition or a hardware malfunction, allowing for immediate automated safety protocols.

Is this transmitter suitable for installation on marine vessels?

Yes, the EMP 2 series is specifically designed for maritime and industrial use. Its heavy-duty design and terminal block connection are ideal for the high-vibration and high-humidity environments typical of shipboard machinery spaces.

Does this unit require a specific orientation for mounting?

While the transmitter can be mounted in any orientation, it is best practice to mount it with the pressure connection facing downwards. This prevents sediment or air pockets from becoming trapped in the sensor cavity, which could affect the 0.3 percent BFSL non-linearity performance.


Engineering & Installation Guide

  • Wiring and Polarity: The 084G2106 is a two-wire transmitter. Ensure the + supply is connected to the P terminal and the - common to the N terminal. Reversing polarity will not damage the unit due to integrated protection but will result in zero signal output. Use the Pg 13.5 cable gland to maintain the IP65 seal.

  • Pressure Port Sealing: When installing the G 1/2 male/female connection (EN 228-1), use a flat copper or metal-plastic sealing washer. Avoid using PTFE tape on the threads if possible, as fragments can migrate into the pressure port and block the internal diaphragm, leading to slow response times or inaccurate readings.

  • Thermal Isolation: Although the transmitter is compensated up to 70 deg C, if the medium temperature exceeds 70 deg C, use a pigtail siphon or a cooling leg to isolate the sensor from the heat. This ensures the electronics remain within the specified compensated temperature range (0 to 70 deg C) to maintain the 0.5 percent typical accuracy.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...